­º­¶> ºô¸ô³]³Æ/ÀW¼eºÞ²z

>>ÂsÄý©Ò¦³BROCADEºô¸ô³]³Æ/ÀW¼eºÞ²z

BROCADE
Brocade NetIron CER 2000 Series switch

«¬¸¹¡GNI-CER2024C-ADVPREM-AC


BROCADENI-CER2024C-ADVPREM-AC


°Ñ¦Ò°â»ù¡G½Ð¥ß§Y¨Ó¹q ¤O±ô¸ê°T
( »ù®æ¯}Ãa¦æ±¡¡I¨Ó¹q¬¢¸ß)



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºBROCADE - NI-CER2024C-ADVPREM-AC - ºô¸ô³]³Æ/ÀW¼eºÞ²z
³Ì¦nªºBROCADE - Brocade NetIron CER 2000 Series switch±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´Úºô¸ô³]³Æ/ÀW¼eºÞ²z Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  
 ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óBROCADE¬ÛÃö²£«~½Ð¥ß§Y¨Ó¹q
¤O±ô¸ê°T ServerBank ¹q¸Ü:(02)8969-0901
¸ß»ùEmail service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù
¦Û°Ê¦C¦L³ø»ù³æ(¤´¥i¨Ó¹q¸ß°Ý§é¦©´T«×)


ÂsÄý³W®æ¬Ûªñ¤§BROCADE²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>






¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§BROCADE­ì¼t°t¥ó


¡@

¡@

¡@

Feature:

¡¹Comprehensive IPv4 unicast routing support based on the Brocade Multi-Service IronWare OS

  • High-performance, robust routing using Forwarding Information Base (FIB) programming in hardware

  • RIP, OSPF, IS-IS, and BGP-4 support

  • Secure Multi-VRF routing for supporting virtual routing applications over non-MPLS backbones

  • Support for VRRP and VRRP-E

  • 8-path Equal-Cost Multipath (ECMP)

  • Up to 512,000 IPv4 unicast routes in Forwarding Information Base (FIB) stack members

¡¹Rich multicast support

  • Supported IPv4 multicast protocols, including PIM-DM, PIM-SM, and PIM-SSM

  • IGMP v2/v3 routing and snooping support

  • IGMP static group support

  • Multicast boundaries to facilitate admission control

  • Up to 6000 multicast groups in hardware

  • Multicast traffic distribution over Link Aggregation Groups (LAGs)

  • Efficient egress interface-based replication to maximize performance and conserve buffers

¡¹Advanced MPLS features

  • Comprehensive MPLS signaling and path calculation algorithms for both traffic-engineered and non-traffic-engineered applications: OSPF-TE, IS-IS-TE, RSVP-TE, and CSPF

  • MPLS Fast ReRoute (FRR) and hot standby paths for traffic protection

  • Label Distribution Protocol (LDP)

  • MPLS Layer 2 VPN services: Virtual Leased Line (VLL) and Virtual Private LAN Service (VPLS)

¡¹Advanced Carrier-Grade Ethernet services

  • Up to 128,000 MAC addresses

  • 4000 VLANs/S-VLANs/B-VLANs

  • Ability to reuse VLAN-ID on each port using the Brocade Ethernet Service Instance (ESI) framework

  • MPLS Layer 2 VPN services

  • IEEE 802.1ad Provider Bridges

  • IEEE 802.1ah Provider Backbone Bridges

  • IEEE 802.1ag Connectivity Fault Management

  • Comprehensive set of Layer 2 control protocols: Brocade MRP/MRP-II, VSRP, RSTP, and MSTP

  • MEF 9, MEF 14, and MEF 21 certification

  • E-LINE (EPL and EVPL), E-LAN, and E-TREE support

  • Protocol tunneling of Bridge Protocol Data Units (BPDUs)

¡¹Support for link aggregation using either IEEE 802.3ad LACP or static trunks

  • Up to 12 ports per LAG

  • Support for single-link Link Aggregation Control Protocol (LACP)

¡¹Deep egress buffering for transient bursts in traffic

  • 64 to 192 MB of buffering, based on configuration

¡¹Advanced QoS

  • Inbound and outbound two-rate three-color traffic policers with accounting

  • Eight queues per port, each with a distinct priority level

  • Multiple queue servicing disciplines: Strict Priority, Weighted Fair Queuing, and hybrid

  • Advanced remarking capabilities based on port, VLAN, PCP, DSCP, or IPv4 flow

  • Egress port and priority-based shaping

¡¹Comprehensive hardware-based security and policies

  • Hardware-based Layer 3 and Layer 2 ACLs (both inbound and outbound) with logging

  • Ability to bind multiple ACLs to the same port

  • Hardware-based receive ACLs

¡¹Additional security capabilities

  • Port-based network access control using 802.1x or MAC port security

  • Root guard and BPDU guard

  • Broadcast, multicast, and unknown unicast rate limits

  • ARP inspection for static entries

¡¹Advanced monitoring capabilities

  • Port- and ACL-based mirroring that enables traffic mirroring based on incoming port, VLAN-ID, or IPv4/TCP/UDP flow

  • Hardware-based sFlow sampling that allows extensive Layer 2-7 traffic monitoring for IPv4 and Carrier Ethernet services

  • ACL-based sFlow support

¡¹Interface capabilities

  • Jumbo frame support up to 9216 bytes

  • Optical monitoring of SFP and XFP optics for fast detection of fiber faults

  • UDLD and LFS/RFN support

¡¹Intuitive, comprehensive status indication via LEDs

  • Per-port UP/DOWN/ACTIVITY indicators

  • FAN tray status

  • Power supply status

¡¹Redundancy

  • Redundant, hot-swappable AC/DC power supplies at the rear

  • Removable fan tray with fan redundancy


BROCADE
Brocade NetIron CER 2000 Series switch - ServerBank¸ê°T±ÄÁʺô
NI-CER2024C-ADVPREM-AC
ºô¸ô³]³Æ/ÀW¼eºÞ²z


¡@
²£«~³W®æ
spec
NI-CER2024C-ADVPREM-AC 24x1 G Copper (RJ45) with four combination 100/1000 SFP ports, one optional 2x10 G slot, one 500-watt AC power supply, and advanced software license
IEEE compliance
  • IEEE 802.3 10Base-T
  • IEEE 802.3u 100Base-TX, 100Base-FX, 100Base-LX
  • IEEE 802.3z 1000Base-SX/LX
  • IEEE 802.3ab 1000Base-T
  • 802.3 CSMA/CD AcCERs Method and Physical Layer Specifications
  • 802.3ae 10 Gigabit Ethernet
  • 802.3x Flow Control
  • 802.3ad Link Aggregation
  • 802.1Q Virtual Bridged LANs
  • 802.1D MAC Bridges
  • 802.1w Rapid STP
  • 802.1s Multiple Spanning Trees
  • 802.1x Port-based Network Access Control
  • 802.1ad Provider Bridges
  • 802.1ah Provider Backbone Bridges
  • 802.1ag Connectivity Fault Management (CFM)

¡@

MEF specifications
  • MEF 2 Requirements and Framework for Ethernet Service Protection
  • MEF 4 Metro Ethernet Network Architecture Framework Part 1: Generic Framework
  • MEF 6.1 Metro Ethernet Services Definitions Phase 2
  • MEF 9 Abstract Test Suite for Ethernet ServiCER at the UNI
  • MEF 10.1 Ethernet Services Attributes Phase 2
  • MEF 11 User Network Interface (UNI) Requirements and Framework
  • MEF 12 Metro Ethernet Network Architecture Framework Part 2: Ethernet Services Layer
  • MEF 13 User Network Interface (UNI) Type 1 Implementation Agreement
  • MEF 14 Abstract Test Suite for Traffic Management Phase 1
  • MEF 15 Requirements for Management of Metro Ethernet Phase 1 Network Elements
  • MEF 17 Service OAM Framework and Requirements (partial)
  • MEF 19 Abstract Test Suite for UNI Type 1
  • MEF 21 Abstract Test Suite for UNI Type 2 Part 1 Link OAM

¡@

RFC compliance
BGPv4
  • RFC 4271 BGPv4
  • RFC 1745 OSPF Interactions
  • RFC 1997 Communities and Attributes
  • RFC 2439 Route Flap Dampening
  • RFC 2796 Route Reflection
  • RFC 1965 BGP4 Confederations
  • RFC 2842 Capability Advertisement
  • RFC 2918 Route Refresh Capability
  • RFC 1269 Managed Objects for BGP
  • RFC 2385 BGP Session Protection via TCP MD5
  • RFC 3682 Generalized TTL Security Mechanism, for eBGP Session Protection
  • RFC 4273 BGP-4 MIB
  • RFC 4893 BGP Support for Four-octet AS Number Space
  • RFC 5396 Textual Representation of Autonomous System (AS) Numbers
  • draft-ietf-idr-restart Graceful Restart Mechanism for BGP (helper mode)
OSPF
  • RFC 2328 OSPF v2
  • RFC 3101 OSPF NSSA
  • RFC 1745 OSPF Interactions
  • RFC 1765 OSPF Database Overflow
  • RFC 1850 OSPF v2 MIB
  • RFC 2370 OSPF Opaque LSA Option
  • RFC 3630 TE Extensions to OSPF v2
  • RFC 3623 Graceful OSPF Restart (helper mode)
IS-IS
  • RFC 1195 Routing in TCP/IP and Dual Environments
  • RFC 1142 OSI IS-IS Intra-domain Routing Protocol
  • RFC 2763 Dynamic Host Name Exchange
  • RFC 2966 Domain-wide Prefix Distribution
RIP
  • RFC 1058 RIP v1
  • RFC 1723 RIP v2
  • RFC 1812 RIP Requirements
IPv4 multicast
  • RFC 1122 Host Extensions
  • RFC 1112 IGMP
  • RFC 2236 IGMP v2
  • RFC 3376 IGMP v3
  • RFC 3973 PIM-DM
  • RFC 2362 PIM-SM
MPLS
  • RFC 3031 MPLS Architecture
  • RFC 3032 MPLS Label Stack Encoding
  • RFC 3036 LDP Specification
  • RFC 2205 RSVP v1 Functional Specification
  • RFC 2209 RSVP v1 Message Processing Rules
  • RFC 3209 RSVP-TE
  • RFC 3270 MPLS Support of Differentiated Services
  • RFC 3812 MPLS MIB
  • RFC 4090 Fast Reroute Extensions to RSVP-TE for LSP Tunnels; partial support
L2VPN and PWE3
  • draft-ietf-l2vpn-framework Framework for Layer 2 Virtual Private Networks
  • draft-ietf-l2vpn-requirements Service Requirements for Layer 2 Provider Provisioned Virtual Private Networks
  • RFC 4762 VPLS using LDP Signaling
  • draft-ietf-pwe3-arch PWE3 Architecture
  • RFC 4447 Pseudowire Setup and Maintenance using LDP
  • RFC 4448 Encapsulation Methods for Transport of Ethernet over MPLS Networks
  • draft-ietf-pwe3-pw-tc-mib Definitions for Textual Conventions and OBJECT-IDENTITIES for Pseudo-Wires Management
  • draft-ietf-pwe3-pw-mib Pseudo Wire (PW) Management Information Base
General protocols
  • RFC 791 IP
  • RFC 792 ICMP
  • RFC 793 TCP
  • RFC 783 TFTP
  • RFC 826 ARP
  • RFC 768 UDP
  • RFC 894 IP over Ethernet
  • RFC 903 RARP
  • RFC 906 TFTP Bootstrap
  • RFC 1027 Proxy ARP
  • RFC 951 BootP
  • RFC 1122 Host Extensions for IP Multicasting
  • RFC 1256 IRDP
  • RFC 1519 CIDR
  • RFC 1542 BootP Extensions
  • RFC 1812 Requirements for IPv4 Routers
  • RFC 1541 and 1542 DHCP
  • RFC 2131 BootP/DHCP Helper
  • RFC 3768 VRRP
  • RFC 854 TELNET
  • RFC 1591 DNS (client)
QoS
  • RFC 2475 An Architecture for Differentiated Services
  • RFC 3246 An Expedited Forwarding PHB
  • RFC 2597 Assured Forwarding PHB Group
  • RFC 2698 A Two-Rate Three-Color Marker
Other
  • RFC 1354 IP Forwarding MIB
  • RFC 2665 Ethernet Interface MIB
  • RFC 1757 RMON Groups 1, 2, 3, 9
  • RFC 2068 HTTP
  • RFC 2030 SNTP
  • RFC 2865 RADIUS
  • RFC 3176 sFlow
  • RFC 2863 Interfaces Group MIB
  • Draft-ietf-tcpm-tcpsecure TCP Security
  • draft-ietf-bfd-base Bidirectional Forwarding Detection (BFD)
Network management

¡@

  • Brocade IronView Network Manager Web-based GUI
  • Integrated industry-standard Command Line Interface (CLI)
  • sFlow (RFC 3176)
  • Telnet
  • SNMP v1, v2c, v3
  • SNMP MIB II
  • RMON

¡@

Element security options
  • AAA
  • RADIUS
  • Secure Shell (SSH v2)
  • Secure Copy (SCP v2)
  • HTTPs
  • TACACS/TACACS+
  • Username/Password (Challenge and Response)
  • Bi-level Access Mode (Standard and EXEC Level)
  • Protection against Denial of Service attacks, such as TCP SYN or Smurf attacks

¡@

Environmental
Temperature Operating: 0¢X C to 40¢X C (32¢X F to 104¢X F)
Non-operating: -25¢X C to 70¢X C (-13¢X F to 158¢X F)
Humidity Relative: 5% to 90% at 40¢X C (104¢X F), non-condensing
Non-operating: 95% maximum relative humidity, non-condensing
Altitude Operating: 10,000 ft (3048 m)
Non-operating: 15,000 ft (4500 m) maximum
Safety agency approvals

¡@

  • CAN/CSA-C22.2 No. 60950-1-3
  • UL 60950-1
  • IEC 60950-1
  • EN 60950-1 Safety of Information Technology Equipment
  • EN 60825-1 Safety of Laser Products¡XPart 1: Equipment Classification, Requirements and User¡¦s Guide
  • EN 60825-2 Safety of Laser Products¡XPart 2: Safety of Optical Fibre Communication Systems
Electromagnetic emission
  • ICES-003 Electromagnetic Emission
  • FCC Class A
  • EN 55022/CISPR-22 Class A/VCCI Class A
  • AS/NZS 55022
  • EN 61000-3-2 Power Line Harmonics
  • EN 61000-3-3 Voltage Fluctuation and Flicker
  • EN 61000-6-3 Emission Standard (Supersedes: EN 50081-1)
Immunity

¡@

  • EN 61000-6-1 Generic Immunity and Susceptibility; this supersedes EN 50082-1
  • EN 55024 Immunity Characteristics. This supersedes:
    • EN 61000-4-2 ESD
    • EN 61000-4-3 Radiated, radio frequency, electromagnetic field
    • EN 61000-4-4 Electrical fast transient
    • EN 61000-4-5 Surge
    • EN 61000-4-6 Conducted disturbances induced by radio-frequency fields
    • EN 61000-4-8 Power frequency magnetic field
    • EN 61000-4-11 Voltage dips and sags
Telco NEBS/ETSI

¡@

  • Telcordia GR-63-CORE NEBS Requirements: Physical Protection
  • Telcordia GR-1089-CORE EMC and Electrical Safety
  • Telcordia SR-3580 Level 3
  • ETSI ETS 300-019 Physical Protection:
    • Part 1-1, Class 1.1, Partly Temperature Controlled Storage Locations
    • Part 1-2, Class 2.3, Public Transportation
    • Part 1-3, Class 3.1, Temperature Controlled Locations (Operational)
  • ETSI ETS 300-386 EMI/EMC

¡@

Power and grounding
  • ETS 300 132-1 Equipment Requirements for AC Power Equipment Derived from DC Sources
  • ETS 300 132-2 Equipment Requirements for DC Powered Equipment
  • ETS 300 253 Facility Requirements

¡@

Physical design and mounting
Rack mount 19-inch rack mount supporting racks compliant with:
  • ANSI/EIA-310-D
  • ETS 300 119
  • GR-63-CORE Seismic Zone 4
Environmental Regulatory Compliance
  • EU 2002/95/EC RoHS
  • EU 2002/96/EC WEEE

¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºBROCADE - NI-CER2024C-ADVPREM-AC - ºô¸ô³]³Æ/ÀW¼eºÞ²z ,³Ì¦nªºBROCADE - Brocade NetIron CER 2000 Series switch±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú

¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C¡@

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B

 

 


¡@
         ServerBank ¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m@
         ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó
         ¹q¸Ü:
(02)8969-0901
          service@serverbank.com.tw
          www.ServerBank.com.tw
ServerBank¤O±ô­º­¶

¥þ³¡¤ÀÃþ | ¦Cªí | «~µP | ¶i¶¥·j´M | §Þ³N¤ä´©
¡@
¡@
¹q¸Ü(02)8969-0901
¡@
 ServerBank¼ö½æ¾÷ºØ
 ÀW¼e­t¸ü¥­¿Å
 2 WAN
 3 WAN
 4 WAN
 8 WAN¤Î¥H¤W
 ¾÷½c«¬¥æ´«¾¹
 ¥æ´«¾¹¼Ò²Õ
 µL½u¸ô¥Ñ¾¹
 ¤u·~¯ÅPOE¥æ´«¾¹
 ¤u·~¯Å¥æ´«¾¹
 ¤u·~¯Å¤á¥~«¬L2
 µL½u°T¸¹ÂX¥R¾¹
 ¤u·~¯ÅºôºÞ¥æ´«¾¹L2
 ¥ø·~¥æ´«¾¹
 ºÞ²z¾÷«¬
 ¤A¤Óºô¸ô¹q·½¨ÑÀ³¾¹
 ºô¸ô¥æ´«¾¹
 ¤u·~¯Å«DºôºÞ¥æ´«¾¹
 4G LTE¹h¹D¾¹
 L2 Switch
 µL½uºô¸ô±±¨î¾¹
 µL½u¼öÂI»{ÃÒ¹h¹D¾¹
 ±µ¤J¼h¥æ´«¾¹
 Wi-Fi AP
 ºôºÞ¥æ´«¾¹
 ÀW¼eºÞ²zQoS
 ¤@¯ë®à¤W«¬¥æ´«¾¹L2
 ºôºÞ¥æ´«¾¹L2
 ¤@¯ë¥æ´«¾¹L2
 L3 Switch
 L4 Switch
 PoE Switch
 ¼eÀWIP¤À¨É¾¹
 ¹q«H¯Å¸ô¥Ñ¾¹Router
 ¥ø·~¥Î¸ô¥Ñ¾¹Router
 ¦C¦L¦øªA¾¹
 §ë¼v¾÷¦øªA¾¹
 ºô¸ô¥d
 µL½uºô¸ôWLAN
 ¶°½u¾¹Hub
 µL½u°ò¦a¥x
«P¾P¬¡°Ê



¡@


ServerBank ¤O±ô¸ê°TServerBank¸ê°T±ÄÁʺô > ºô¸ô³]³Æ/ÀW¼eºÞ²z


BROCADENI-CER2024C-ADVPREM-AC

Brocade NetIron CER 2000 Series switch


¼tµP¡GBROCADE      >>ÂsÄýBROCADE¥þ³¡²£«~
«¬¸¹¡GNI-CER2024C-ADVPREM-AC



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºBROCADE - NI-CER2024C-ADVPREM-AC - ºô¸ô³]³Æ/ÀW¼eºÞ²z ,³Ì¦nªºBROCADE - Brocade NetIron CER 2000 Series switch±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´Úºô¸ô³]³Æ/ÀW¼eºÞ²z Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  

 

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óBROCADE¬ÛÃö²£«~, ½Ð¥ß§Y¨Ó¹q(02)8969-0901
¤O±ô¸ê°T ServerBank ¸ß»ùEmail: service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù


ÂsÄý³W®æ¬Ûªñ¤§BROCADE²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>
¦Û°Ê¦C¦L³ø»ù³æ(½Ð¨Ó¹q¸ß°Ý§é¦©­°´T)






ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I
¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§BROCADE­ì¼t°t¥ó


¡@

¡@

¡@

Feature:

¡¹Comprehensive IPv4 unicast routing support based on the Brocade Multi-Service IronWare OS

  • High-performance, robust routing using Forwarding Information Base (FIB) programming in hardware

  • RIP, OSPF, IS-IS, and BGP-4 support

  • Secure Multi-VRF routing for supporting virtual routing applications over non-MPLS backbones

  • Support for VRRP and VRRP-E

  • 8-path Equal-Cost Multipath (ECMP)

  • Up to 512,000 IPv4 unicast routes in Forwarding Information Base (FIB) stack members

¡¹Rich multicast support

  • Supported IPv4 multicast protocols, including PIM-DM, PIM-SM, and PIM-SSM

  • IGMP v2/v3 routing and snooping support

  • IGMP static group support

  • Multicast boundaries to facilitate admission control

  • Up to 6000 multicast groups in hardware

  • Multicast traffic distribution over Link Aggregation Groups (LAGs)

  • Efficient egress interface-based replication to maximize performance and conserve buffers

¡¹Advanced MPLS features

  • Comprehensive MPLS signaling and path calculation algorithms for both traffic-engineered and non-traffic-engineered applications: OSPF-TE, IS-IS-TE, RSVP-TE, and CSPF

  • MPLS Fast ReRoute (FRR) and hot standby paths for traffic protection

  • Label Distribution Protocol (LDP)

  • MPLS Layer 2 VPN services: Virtual Leased Line (VLL) and Virtual Private LAN Service (VPLS)

¡¹Advanced Carrier-Grade Ethernet services

  • Up to 128,000 MAC addresses

  • 4000 VLANs/S-VLANs/B-VLANs

  • Ability to reuse VLAN-ID on each port using the Brocade Ethernet Service Instance (ESI) framework

  • MPLS Layer 2 VPN services

  • IEEE 802.1ad Provider Bridges

  • IEEE 802.1ah Provider Backbone Bridges

  • IEEE 802.1ag Connectivity Fault Management

  • Comprehensive set of Layer 2 control protocols: Brocade MRP/MRP-II, VSRP, RSTP, and MSTP

  • MEF 9, MEF 14, and MEF 21 certification

  • E-LINE (EPL and EVPL), E-LAN, and E-TREE support

  • Protocol tunneling of Bridge Protocol Data Units (BPDUs)

¡¹Support for link aggregation using either IEEE 802.3ad LACP or static trunks

  • Up to 12 ports per LAG

  • Support for single-link Link Aggregation Control Protocol (LACP)

¡¹Deep egress buffering for transient bursts in traffic

  • 64 to 192 MB of buffering, based on configuration

¡¹Advanced QoS

  • Inbound and outbound two-rate three-color traffic policers with accounting

  • Eight queues per port, each with a distinct priority level

  • Multiple queue servicing disciplines: Strict Priority, Weighted Fair Queuing, and hybrid

  • Advanced remarking capabilities based on port, VLAN, PCP, DSCP, or IPv4 flow

  • Egress port and priority-based shaping

¡¹Comprehensive hardware-based security and policies

  • Hardware-based Layer 3 and Layer 2 ACLs (both inbound and outbound) with logging

  • Ability to bind multiple ACLs to the same port

  • Hardware-based receive ACLs

¡¹Additional security capabilities

  • Port-based network access control using 802.1x or MAC port security

  • Root guard and BPDU guard

  • Broadcast, multicast, and unknown unicast rate limits

  • ARP inspection for static entries

¡¹Advanced monitoring capabilities

  • Port- and ACL-based mirroring that enables traffic mirroring based on incoming port, VLAN-ID, or IPv4/TCP/UDP flow

  • Hardware-based sFlow sampling that allows extensive Layer 2-7 traffic monitoring for IPv4 and Carrier Ethernet services

  • ACL-based sFlow support

¡¹Interface capabilities

  • Jumbo frame support up to 9216 bytes

  • Optical monitoring of SFP and XFP optics for fast detection of fiber faults

  • UDLD and LFS/RFN support

¡¹Intuitive, comprehensive status indication via LEDs

  • Per-port UP/DOWN/ACTIVITY indicators

  • FAN tray status

  • Power supply status

¡¹Redundancy

  • Redundant, hot-swappable AC/DC power supplies at the rear

  • Removable fan tray with fan redundancy


BROCADE
Brocade NetIron CER 2000 Series switch - ServerBank¸ê°T±ÄÁʺô
NI-CER2024C-ADVPREM-AC
ºô¸ô³]³Æ/ÀW¼eºÞ²z


¡@
²£«~³W®æ
spec
NI-CER2024C-ADVPREM-AC 24x1 G Copper (RJ45) with four combination 100/1000 SFP ports, one optional 2x10 G slot, one 500-watt AC power supply, and advanced software license
IEEE compliance
  • IEEE 802.3 10Base-T
  • IEEE 802.3u 100Base-TX, 100Base-FX, 100Base-LX
  • IEEE 802.3z 1000Base-SX/LX
  • IEEE 802.3ab 1000Base-T
  • 802.3 CSMA/CD AcCERs Method and Physical Layer Specifications
  • 802.3ae 10 Gigabit Ethernet
  • 802.3x Flow Control
  • 802.3ad Link Aggregation
  • 802.1Q Virtual Bridged LANs
  • 802.1D MAC Bridges
  • 802.1w Rapid STP
  • 802.1s Multiple Spanning Trees
  • 802.1x Port-based Network Access Control
  • 802.1ad Provider Bridges
  • 802.1ah Provider Backbone Bridges
  • 802.1ag Connectivity Fault Management (CFM)

¡@

MEF specifications
  • MEF 2 Requirements and Framework for Ethernet Service Protection
  • MEF 4 Metro Ethernet Network Architecture Framework Part 1: Generic Framework
  • MEF 6.1 Metro Ethernet Services Definitions Phase 2
  • MEF 9 Abstract Test Suite for Ethernet ServiCER at the UNI
  • MEF 10.1 Ethernet Services Attributes Phase 2
  • MEF 11 User Network Interface (UNI) Requirements and Framework
  • MEF 12 Metro Ethernet Network Architecture Framework Part 2: Ethernet Services Layer
  • MEF 13 User Network Interface (UNI) Type 1 Implementation Agreement
  • MEF 14 Abstract Test Suite for Traffic Management Phase 1
  • MEF 15 Requirements for Management of Metro Ethernet Phase 1 Network Elements
  • MEF 17 Service OAM Framework and Requirements (partial)
  • MEF 19 Abstract Test Suite for UNI Type 1
  • MEF 21 Abstract Test Suite for UNI Type 2 Part 1 Link OAM

¡@

RFC compliance
BGPv4
  • RFC 4271 BGPv4
  • RFC 1745 OSPF Interactions
  • RFC 1997 Communities and Attributes
  • RFC 2439 Route Flap Dampening
  • RFC 2796 Route Reflection
  • RFC 1965 BGP4 Confederations
  • RFC 2842 Capability Advertisement
  • RFC 2918 Route Refresh Capability
  • RFC 1269 Managed Objects for BGP
  • RFC 2385 BGP Session Protection via TCP MD5
  • RFC 3682 Generalized TTL Security Mechanism, for eBGP Session Protection
  • RFC 4273 BGP-4 MIB
  • RFC 4893 BGP Support for Four-octet AS Number Space
  • RFC 5396 Textual Representation of Autonomous System (AS) Numbers
  • draft-ietf-idr-restart Graceful Restart Mechanism for BGP (helper mode)
OSPF
  • RFC 2328 OSPF v2
  • RFC 3101 OSPF NSSA
  • RFC 1745 OSPF Interactions
  • RFC 1765 OSPF Database Overflow
  • RFC 1850 OSPF v2 MIB
  • RFC 2370 OSPF Opaque LSA Option
  • RFC 3630 TE Extensions to OSPF v2
  • RFC 3623 Graceful OSPF Restart (helper mode)
IS-IS
  • RFC 1195 Routing in TCP/IP and Dual Environments
  • RFC 1142 OSI IS-IS Intra-domain Routing Protocol
  • RFC 2763 Dynamic Host Name Exchange
  • RFC 2966 Domain-wide Prefix Distribution
RIP
  • RFC 1058 RIP v1
  • RFC 1723 RIP v2
  • RFC 1812 RIP Requirements
IPv4 multicast
  • RFC 1122 Host Extensions
  • RFC 1112 IGMP
  • RFC 2236 IGMP v2
  • RFC 3376 IGMP v3
  • RFC 3973 PIM-DM
  • RFC 2362 PIM-SM
MPLS
  • RFC 3031 MPLS Architecture
  • RFC 3032 MPLS Label Stack Encoding
  • RFC 3036 LDP Specification
  • RFC 2205 RSVP v1 Functional Specification
  • RFC 2209 RSVP v1 Message Processing Rules
  • RFC 3209 RSVP-TE
  • RFC 3270 MPLS Support of Differentiated Services
  • RFC 3812 MPLS MIB
  • RFC 4090 Fast Reroute Extensions to RSVP-TE for LSP Tunnels; partial support
L2VPN and PWE3
  • draft-ietf-l2vpn-framework Framework for Layer 2 Virtual Private Networks
  • draft-ietf-l2vpn-requirements Service Requirements for Layer 2 Provider Provisioned Virtual Private Networks
  • RFC 4762 VPLS using LDP Signaling
  • draft-ietf-pwe3-arch PWE3 Architecture
  • RFC 4447 Pseudowire Setup and Maintenance using LDP
  • RFC 4448 Encapsulation Methods for Transport of Ethernet over MPLS Networks
  • draft-ietf-pwe3-pw-tc-mib Definitions for Textual Conventions and OBJECT-IDENTITIES for Pseudo-Wires Management
  • draft-ietf-pwe3-pw-mib Pseudo Wire (PW) Management Information Base
General protocols
  • RFC 791 IP
  • RFC 792 ICMP
  • RFC 793 TCP
  • RFC 783 TFTP
  • RFC 826 ARP
  • RFC 768 UDP
  • RFC 894 IP over Ethernet
  • RFC 903 RARP
  • RFC 906 TFTP Bootstrap
  • RFC 1027 Proxy ARP
  • RFC 951 BootP
  • RFC 1122 Host Extensions for IP Multicasting
  • RFC 1256 IRDP
  • RFC 1519 CIDR
  • RFC 1542 BootP Extensions
  • RFC 1812 Requirements for IPv4 Routers
  • RFC 1541 and 1542 DHCP
  • RFC 2131 BootP/DHCP Helper
  • RFC 3768 VRRP
  • RFC 854 TELNET
  • RFC 1591 DNS (client)
QoS
  • RFC 2475 An Architecture for Differentiated Services
  • RFC 3246 An Expedited Forwarding PHB
  • RFC 2597 Assured Forwarding PHB Group
  • RFC 2698 A Two-Rate Three-Color Marker
Other
  • RFC 1354 IP Forwarding MIB
  • RFC 2665 Ethernet Interface MIB
  • RFC 1757 RMON Groups 1, 2, 3, 9
  • RFC 2068 HTTP
  • RFC 2030 SNTP
  • RFC 2865 RADIUS
  • RFC 3176 sFlow
  • RFC 2863 Interfaces Group MIB
  • Draft-ietf-tcpm-tcpsecure TCP Security
  • draft-ietf-bfd-base Bidirectional Forwarding Detection (BFD)
Network management

¡@

  • Brocade IronView Network Manager Web-based GUI
  • Integrated industry-standard Command Line Interface (CLI)
  • sFlow (RFC 3176)
  • Telnet
  • SNMP v1, v2c, v3
  • SNMP MIB II
  • RMON

¡@

Element security options
  • AAA
  • RADIUS
  • Secure Shell (SSH v2)
  • Secure Copy (SCP v2)
  • HTTPs
  • TACACS/TACACS+
  • Username/Password (Challenge and Response)
  • Bi-level Access Mode (Standard and EXEC Level)
  • Protection against Denial of Service attacks, such as TCP SYN or Smurf attacks

¡@

Environmental
Temperature Operating: 0¢X C to 40¢X C (32¢X F to 104¢X F)
Non-operating: -25¢X C to 70¢X C (-13¢X F to 158¢X F)
Humidity Relative: 5% to 90% at 40¢X C (104¢X F), non-condensing
Non-operating: 95% maximum relative humidity, non-condensing
Altitude Operating: 10,000 ft (3048 m)
Non-operating: 15,000 ft (4500 m) maximum
Safety agency approvals

¡@

  • CAN/CSA-C22.2 No. 60950-1-3
  • UL 60950-1
  • IEC 60950-1
  • EN 60950-1 Safety of Information Technology Equipment
  • EN 60825-1 Safety of Laser Products¡XPart 1: Equipment Classification, Requirements and User¡¦s Guide
  • EN 60825-2 Safety of Laser Products¡XPart 2: Safety of Optical Fibre Communication Systems
Electromagnetic emission
  • ICES-003 Electromagnetic Emission
  • FCC Class A
  • EN 55022/CISPR-22 Class A/VCCI Class A
  • AS/NZS 55022
  • EN 61000-3-2 Power Line Harmonics
  • EN 61000-3-3 Voltage Fluctuation and Flicker
  • EN 61000-6-3 Emission Standard (Supersedes: EN 50081-1)
Immunity

¡@

  • EN 61000-6-1 Generic Immunity and Susceptibility; this supersedes EN 50082-1
  • EN 55024 Immunity Characteristics. This supersedes:
    • EN 61000-4-2 ESD
    • EN 61000-4-3 Radiated, radio frequency, electromagnetic field
    • EN 61000-4-4 Electrical fast transient
    • EN 61000-4-5 Surge
    • EN 61000-4-6 Conducted disturbances induced by radio-frequency fields
    • EN 61000-4-8 Power frequency magnetic field
    • EN 61000-4-11 Voltage dips and sags
Telco NEBS/ETSI

¡@

  • Telcordia GR-63-CORE NEBS Requirements: Physical Protection
  • Telcordia GR-1089-CORE EMC and Electrical Safety
  • Telcordia SR-3580 Level 3
  • ETSI ETS 300-019 Physical Protection:
    • Part 1-1, Class 1.1, Partly Temperature Controlled Storage Locations
    • Part 1-2, Class 2.3, Public Transportation
    • Part 1-3, Class 3.1, Temperature Controlled Locations (Operational)
  • ETSI ETS 300-386 EMI/EMC

¡@

Power and grounding
  • ETS 300 132-1 Equipment Requirements for AC Power Equipment Derived from DC Sources
  • ETS 300 132-2 Equipment Requirements for DC Powered Equipment
  • ETS 300 253 Facility Requirements

¡@

Physical design and mounting
Rack mount 19-inch rack mount supporting racks compliant with:
  • ANSI/EIA-310-D
  • ETS 300 119
  • GR-63-CORE Seismic Zone 4
Environmental Regulatory Compliance
  • EU 2002/95/EC RoHS
  • EU 2002/96/EC WEEE

¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank ¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºBROCADE - NI-CER2024C-ADVPREM-AC - ºô¸ô³]³Æ/ÀW¼eºÞ²z ,³Ì¦nªºBROCADE - Brocade NetIron CER 2000 Series switch±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú
¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B


¡@
¡@

ServerBank¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m service@serverbank.com.tw
¹q¸Ü(02)8969-0901 ¶Ç¯u(02)2253-9016 ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó

¡@
¡@