­º­¶> ºô¸ô³]³Æ/ÀW¼eºÞ²z

>>ÂsÄý©Ò¦³ALCATELºô¸ô³]³Æ/ÀW¼eºÞ²z

ALCATEL
Alcatel-Lucent OmniSwitch 6850 L3¸ô¥Ñ¥æ´«¾¹

«¬¸¹¡GOS6850-P24


ALCATELOS6850-P24


°Ñ¦Ò°â»ù¡G½Ð¥ß§Y¨Ó¹q ¤O±ô¸ê°T
( »ù®æ¯}Ãa¦æ±¡¡I¨Ó¹q¬¢¸ß)



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºALCATEL - OS6850-P24 - ºô¸ô³]³Æ/ÀW¼eºÞ²z
³Ì¦nªºALCATEL - Alcatel-Lucent OmniSwitch 6850 L3¸ô¥Ñ¥æ´«¾¹±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´Úºô¸ô³]³Æ/ÀW¼eºÞ²z Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  
 ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óALCATEL¬ÛÃö²£«~½Ð¥ß§Y¨Ó¹q
¤O±ô¸ê°T ServerBank ¹q¸Ü:(02)8969-0901
¸ß»ùEmail service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù
¦Û°Ê¦C¦L³ø»ù³æ(¤´¥i¨Ó¹q¸ß°Ý§é¦©´T«×)


ÂsÄý³W®æ¬Ûªñ¤§ALCATEL²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>






¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§ALCATEL­ì¼t°t¥ó


¡@

¡@

¡@

THE SWITCHES PROVIDE:
¡´ Choice of PoE (Power-over-Ethernet) and non-PoE models
¡´ Triple-speed 10/100/1000 interfaces and 10Gig uplinks
¡´ Fast Ethernet interfaces upgradeable to Gigabit via a software license key without
     any network reconfiguration
¡´ Gigabit fiber interfaces (SFP) supporting 100BaseX, dual-speed and
     1000BaseX optical transceivers
¡´ Stacking capability for virtual chassis redundancy
¡´ Power supply choice (AC, DC, PoE) for flexible deployment
¡´ IPv4 and IPv6 layer-2 and layer-3 switching for future-proof investment
¡´ Advanced quality of service (QoS) to support mission-critical and triple-play applications


ALCATEL
Alcatel-Lucent OmniSwitch 6850 L3¸ô¥Ñ¥æ´«¾¹ - ServerBank¸ê°T±ÄÁʺô
OS6850-P24
ºô¸ô³]³Æ/ÀW¼eºÞ²z


¡@
²£«~³W®æ
Specifications
Indicators

PER PORT LEDS

¡E 10/100/1000: PoE, link/activity

¡E SFP: link/activity

¡E XFP: link/activity

SYSTEM LEDS

¡E Switch ID (indicates the stack ID of the unit in

the stack: 1 to 7)

¡E System (OK) (chassis HW/SW status)

¡E PWR (primary power supply status)

¡E PRI (virtual chassis primary)

¡E BPS (backup power status)

Physical Dimensions (WxDxH)

¡@

CHASSIS SIZE (WITHOUT POWER SUPPLY

OR PS SHELF)

¡E 17.32 x 10.63 x 1.73 in (44.0 x 27.0 x 4.4 cm)

TOTAL SIZE INCLUDING POWER

SUPPLYS SHELF AND MOUNTING EARS

¡E 19.00 x 17.56 x 1.73 in (48.2 x 44.6 x 4.4 cm)

CHASSIS SIZE (WITH MOUNTING

EARS,WITHOUT POWER SUPPLY OR

PS SHELF)

¡E 19 x 10.63 x 1.73 in (48.2 x 27.0 x 4.4 cm)

Weight

CHASSIS WITHOUT THE POWER SUPPLY

¡E OS6850-P24 and -P24L 8.62 lb (3.91kg )

¡E OS6850-P24X 8.86 lb (4.02 kg )

¡E OS6850-P48and -P48L 9.39 lb (4.26kg )

¡E OS6850-P48X 9.59 lb (4.35kg )

¡E OS6850-24 and 24L 8.36 lb (3.79kg )

POWER SUPPLIES

¡E 510W AC 5.71 lb (2.59kg )

¡E 360W AC 3.22 lb (1.46kg )

¡E 126W AC 2.45 lb (1.11kg )

¡E 120W DC 2.09 lb (0.95kg )

¡E Power supply tray 1.26 lb (0.57kg )

EMC

¡@

¡E FCC CRF Title 47 Subpart B (Class A limits.

Note: Class A with UTP cables)

¡E VCCI (Class A limits. Note: Class A with UTP

cables)

¡E AS/NZS 3548 (Class A limits. Note: Class A

with UTP cables)

¡E CE marking for European countries (Class A.

Note: Class A with UTP cables)

¡E EN 55022: 1995 (Emission Standard)

¡E EN 61000-3-3: 1995

¡E EN 61000-3-2: 2000

¡E EN 55024: 1998 (Immunity Standards)

¡E EN 61000-4-2: 1995+A1: 1998

¡E EN 61000-4-3: 1996+A1: 1998

¡E EN 61000-4-4: 1995

¡E EN 61000-4-5: 1995

¡E EN 61000-4-6: 1996

¡E EN 61000-4-8: 1994

¡E EN 61000-4-11: 1994

¡E IEEE802.3: Hi-Pot Test (2250 VDC on all

Ethernet ports)

Safety Agency Certifications

¡E US UL 60950

¡E IEC 60950-1:2001; all national deviations

¡E EN 60950-1: 2001; all deviations

¡E CAN/CSA-C22.2 No. 60950-1-03

¡E NOM-019 SCFI, Mexico

¡E AS/NZ TS-001 and 60950:2000, Australia

¡E UL-AR, Argentina

¡E UL-GS Mark, Germany

¡E EN 60825-1 Laser, EN60825-2 Laser

¡E CDRH Laser

¡E China CCC

¡@

IEEE Standards

¡@

¡E IEEE 802.1D (STP)

¡E IEEE 802.1p (CoS)

¡E IEEE 802.1Q (VLANs)

¡E IEEE 802.1QinQ(VLAN stacking)

¡E IEEE 802.1ag (Connectivity Fault

Management)

¡E IEEE 802.1s (MSTP)

¡E IEEE 802.1w (RSTP)

¡E IEEE 802.1X (Port Based Network Access

Protocol)

¡E IEEE 802.3i (10BaseT)

¡E IEEE 802.3u (Fast Ethernet)

¡E IEEE 802.3x (Flow Control)

¡E IEEE 802.3z (Gigabit Ethernet)

¡E IEEE 802.3ab (1000BaseT)

¡E IEEE 802.3ac (VLAN Tagging)

¡E IEEE 802.3ad (Link Aggregation)

¡E IEEE 802.3af (Power-over-Ethernet)

¡E IEEE 802.3ae (10G Ethernet)

¡@

Environmental requirements

¡@

OPERATING TEMPERATURE:

¡E 32¢X to 113¢XF (0¢X to 45¢XC)

STORAGE TEMPERATURE:

¡E 14¢X to 158¢XF (-10¢X to 70¢XC)

HUMIDITY (OPERATING AND STORAGE):

¡E 5% to 95% non-condensing

¡@

IETF Standards

¡@

BGP

¡E RFC 1269/1657 BGP v3 & v4 MIB

¡E RFC 1403/1745 BGP/OSPF Interaction

¡E RFC 1771-1774/2842/2918/3392 BGP v4

¡E RFC 1965 BGP AS Confederations

¡E RFC 1966 BGP Route Reflection

¡E RFC 1997/1998 BGP Communities Attribute

¡E RFC 2042 BGP New Attribute

¡E RFC 2385 BGP MD5 Signature

¡E RFC 2439 BGP Route Flap Damping

¡E RFC 2796 BGP Route Reflection

¡E RFC 3065 BGP AS Confederations

OSPF

¡E RFC 1253/1850/2328 OSPF v2 & MIB

¡E RFC 1587/3101 OSPF NSSA Option

¡E RFC 1765 OSPF Database Overflow

¡E RFC 2154 OSPF MD5 Signature

¡E RFC 2370/3630 OSPF Opaque LSA

¡E RFC 3623 OSPF Graceful Restart

RIP

¡E RFC 1058 RIP v1

¡E RFC 1722/1723/2453/1724 RIP v2 & MIB

¡E RFC 1812/2644 IPv4 Router Requirement

¡E RFC 2080 RIPS ng

IS-IS

¡E RFC 1142 OSI IS-IS Intra-domain Routing

Protocol

¡E RFC 1195 Use of OSI IS-IS for routing in

TCP/IP & dual environments

¡E RFC 2763 Dynamic Hostname Exchange

for IS-IS

IP MULTICAST

¡E RFC 1075 DVMRP

¡E RFC 1112 IGMP v1

¡E RFC 2236/2933 IGMP v2 & MIB

¡E RFC 2362 PIM-SM

¡E RFC 2365 Multicast

¡E RFC 2715/2932 Multicast Routing MIB

¡E RFC 2934 PIM MIB for IPv4

¡E RFC 3376 IGMPv3

IPV6

¡E RFC 1886 DNS for IPv6

¡E RFC 2292/2373/2374/2460/2462 IPv6

¡E RFC 2461 NDP

¡E RFC 2463/2466 ICMP v6 & MIB

¡E RFC 2452/2454 IPv6 TCP/UDP MIB

¡E RFC 2464/2553/2893/3493/3513 IPv6

¡E RFC 3056 IPv6 Tunneling

¡E RFC 3542/3587 IPv6

MANAGEABILITY

¡E RFC 854/855 Telnet & Telnet options

¡E RFC 1155/2578-2580 SMI v1 & SMI v2

¡E RFC 1157/2271 SNMP

¡E RFC 1212/2737 MIB & MIB-II

¡E RFC 1213/2011-2013 SNMP v2 MIB

¡E RFC 1215 Convention for SNMP Traps

¡E RFC 1573/2233/2863 Private Interface MIB

¡E RFC 1643/2665 Ethernet MIB

¡E RFC 1901-1908/3416-3418 SNMP v2c

¡E RFC 2096 IP MIB

¡E RFC 2570-2576/3411-3415 SNMP v3

¡E RFC 2616 /2854 HTTP & HTML

¡E RFC 2667 IP Tunneling MIB

¡E RFC 2668/3636 IEEE 802.3 MAU MIB

¡E RFC 2674 VLAN MIB

SECURITY

¡E RFC 959/2640 FTP

¡E RFC 1321 MD5

¡E RFC 2104 HMAC Message Authentication

¡E RFC 2138/2865/2868/3575/2618

RADIUSAuthentication & Client MIB

¡E RFC 2139/2866/2867/2620 RADIUS

Accounting & Client MIB

¡E RFC 2228 step

¡E RFC 2284 PPP EAP

¡E RFC 2869/2869bis RADIUS Extension

QUALITY OF SERVICES

¡E RFC 896 Congestion control

¡E RFC 1122 Internet Hosts

¡E RFC 2474/2475/2597/3168/3246 DiffServ

¡E RFC 3635 Pause Control

OTHERS

¡E RFC 791/894/1024/1349 IP & IP / Ethernet

¡E RFC 792 ICMP

¡E RFC 768 UDP

¡E RFC 793/1156 TCP/IP & MIB

¡E RFC 826/903 ARP & Reverse ARP

¡E RFC 919/922 Broadcasting internet datagram

¡E RFC 925/1027 Multi LAN ARP / Proxy ARP

¡E RFC 950 Subnetting

¡E RFC 951 Bootp

¡E RFC 1151 RDP

¡E RFC 1191 Path MTU Discovery

¡E RFC 1256 ICMP Router Discovery

¡E RFC 1305/2030 NTP v3 & Simple NTP

¡E RFC 1493 Bridge MIB

¡E RFC 1518/1519 CIDR

¡E RFC 1541/1542/2131/3396/3442 DHCP

¡E RFC 1757/2819 RMON & MIB

¡E RFC 2131/3046 DHCP/BootP Relay

¡E RFC 2132 DHCP Options

¡E RFC 2251 LDAP v3

¡E RFC 2338/3768/2787 VRRP & MIB

¡E RFC 3060 Policy Core

¡E RFC 3176 sFlow

¡@

Product MTFB (hours) Power
Consumption
Heat Dissapation under
full load (Btu/hour)
Acoustic Level
(dB)***
PoE Models

OS6850-P24

153,497 324 279 under 44dB
OS6850-P24X 148,929 327 289 under 44dB
OS6850-P48 128,390 367 517 under 44dB
OS6850-P48X 119,750 387 584 under 44dB
Non-PoE Models
OS6850-24 200,421 55 188 under 44dB
OS6850-24X 191,695 58 198 under 44dB
OS6850-48 162,844 97 331 under 44dB
OS6850-48X 149,608 117 399 under 44dB
OS6850-U24X 207,199 119 406 under 44dB

¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºALCATEL - OS6850-P24 - ºô¸ô³]³Æ/ÀW¼eºÞ²z ,³Ì¦nªºALCATEL - Alcatel-Lucent OmniSwitch 6850 L3¸ô¥Ñ¥æ´«¾¹±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú

¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C¡@

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B

 

 


¡@
         ServerBank ¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m@
         ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó
         ¹q¸Ü:
(02)8969-0901
          service@serverbank.com.tw
          www.ServerBank.com.tw
ServerBank¤O±ô­º­¶

¥þ³¡¤ÀÃþ | ¦Cªí | «~µP | ¶i¶¥·j´M | §Þ³N¤ä´©
¡@
¡@
¹q¸Ü(02)8969-0901
¡@
 ServerBank¼ö½æ¾÷ºØ
 ÀW¼e­t¸ü¥­¿Å
 2 WAN
 3 WAN
 4 WAN
 8 WAN¤Î¥H¤W
 ¾÷½c«¬¥æ´«¾¹
 ¥æ´«¾¹¼Ò²Õ
 µL½u¸ô¥Ñ¾¹
 ¤u·~¯ÅPOE¥æ´«¾¹
 ¤u·~¯Å¥æ´«¾¹
 ¤u·~¯Å¤á¥~«¬L2
 µL½u°T¸¹ÂX¥R¾¹
 ¤u·~¯ÅºôºÞ¥æ´«¾¹L2
 ¥ø·~¥æ´«¾¹
 ºÞ²z¾÷«¬
 ¤A¤Óºô¸ô¹q·½¨ÑÀ³¾¹
 ºô¸ô¥æ´«¾¹
 ¤u·~¯Å«DºôºÞ¥æ´«¾¹
 4G LTE¹h¹D¾¹
 L2 Switch
 µL½uºô¸ô±±¨î¾¹
 µL½u¼öÂI»{ÃÒ¹h¹D¾¹
 ±µ¤J¼h¥æ´«¾¹
 Wi-Fi AP
 ºôºÞ¥æ´«¾¹
 ÀW¼eºÞ²zQoS
 ¤@¯ë®à¤W«¬¥æ´«¾¹L2
 ºôºÞ¥æ´«¾¹L2
 ¤@¯ë¥æ´«¾¹L2
 L3 Switch
 L4 Switch
 PoE Switch
 ¼eÀWIP¤À¨É¾¹
 ¹q«H¯Å¸ô¥Ñ¾¹Router
 ¥ø·~¥Î¸ô¥Ñ¾¹Router
 ¦C¦L¦øªA¾¹
 §ë¼v¾÷¦øªA¾¹
 ºô¸ô¥d
 µL½uºô¸ôWLAN
 ¶°½u¾¹Hub
 µL½u°ò¦a¥x
«P¾P¬¡°Ê



¡@


ServerBank ¤O±ô¸ê°TServerBank¸ê°T±ÄÁʺô > ºô¸ô³]³Æ/ÀW¼eºÞ²z


ALCATELOS6850-P24

Alcatel-Lucent OmniSwitch 6850 L3¸ô¥Ñ¥æ´«¾¹


¼tµP¡GALCATEL      >>ÂsÄýALCATEL¥þ³¡²£«~
«¬¸¹¡GOS6850-P24



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºALCATEL - OS6850-P24 - ºô¸ô³]³Æ/ÀW¼eºÞ²z ,³Ì¦nªºALCATEL - Alcatel-Lucent OmniSwitch 6850 L3¸ô¥Ñ¥æ´«¾¹±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´Úºô¸ô³]³Æ/ÀW¼eºÞ²z Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  

 

°Ñ¦Ò°â»ù¡G( ¯}Ãa¦æ±¡¼t°Ó¬IÀ£¡I)
¸ß°Ý¥ô¦óALCATEL¬ÛÃö²£«~, ½Ð¥ß§Y¨Ó¹q(02)8969-0901
¤O±ô¸ê°T ServerBank ¸ß»ùEmail: service@serverbank.com.tw



·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù


ÂsÄý³W®æ¬Ûªñ¤§ALCATEL²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>
¦Û°Ê¦C¦L³ø»ù³æ(½Ð¨Ó¹q¸ß°Ý§é¦©­°´T)






ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I
¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§ALCATEL­ì¼t°t¥ó


¡@

¡@

¡@

THE SWITCHES PROVIDE:
¡´ Choice of PoE (Power-over-Ethernet) and non-PoE models
¡´ Triple-speed 10/100/1000 interfaces and 10Gig uplinks
¡´ Fast Ethernet interfaces upgradeable to Gigabit via a software license key without
     any network reconfiguration
¡´ Gigabit fiber interfaces (SFP) supporting 100BaseX, dual-speed and
     1000BaseX optical transceivers
¡´ Stacking capability for virtual chassis redundancy
¡´ Power supply choice (AC, DC, PoE) for flexible deployment
¡´ IPv4 and IPv6 layer-2 and layer-3 switching for future-proof investment
¡´ Advanced quality of service (QoS) to support mission-critical and triple-play applications


ALCATEL
Alcatel-Lucent OmniSwitch 6850 L3¸ô¥Ñ¥æ´«¾¹ - ServerBank¸ê°T±ÄÁʺô
OS6850-P24
ºô¸ô³]³Æ/ÀW¼eºÞ²z


¡@
²£«~³W®æ
Specifications
Indicators

PER PORT LEDS

¡E 10/100/1000: PoE, link/activity

¡E SFP: link/activity

¡E XFP: link/activity

SYSTEM LEDS

¡E Switch ID (indicates the stack ID of the unit in

the stack: 1 to 7)

¡E System (OK) (chassis HW/SW status)

¡E PWR (primary power supply status)

¡E PRI (virtual chassis primary)

¡E BPS (backup power status)

Physical Dimensions (WxDxH)

¡@

CHASSIS SIZE (WITHOUT POWER SUPPLY

OR PS SHELF)

¡E 17.32 x 10.63 x 1.73 in (44.0 x 27.0 x 4.4 cm)

TOTAL SIZE INCLUDING POWER

SUPPLYS SHELF AND MOUNTING EARS

¡E 19.00 x 17.56 x 1.73 in (48.2 x 44.6 x 4.4 cm)

CHASSIS SIZE (WITH MOUNTING

EARS,WITHOUT POWER SUPPLY OR

PS SHELF)

¡E 19 x 10.63 x 1.73 in (48.2 x 27.0 x 4.4 cm)

Weight

CHASSIS WITHOUT THE POWER SUPPLY

¡E OS6850-P24 and -P24L 8.62 lb (3.91kg )

¡E OS6850-P24X 8.86 lb (4.02 kg )

¡E OS6850-P48and -P48L 9.39 lb (4.26kg )

¡E OS6850-P48X 9.59 lb (4.35kg )

¡E OS6850-24 and 24L 8.36 lb (3.79kg )

POWER SUPPLIES

¡E 510W AC 5.71 lb (2.59kg )

¡E 360W AC 3.22 lb (1.46kg )

¡E 126W AC 2.45 lb (1.11kg )

¡E 120W DC 2.09 lb (0.95kg )

¡E Power supply tray 1.26 lb (0.57kg )

EMC

¡@

¡E FCC CRF Title 47 Subpart B (Class A limits.

Note: Class A with UTP cables)

¡E VCCI (Class A limits. Note: Class A with UTP

cables)

¡E AS/NZS 3548 (Class A limits. Note: Class A

with UTP cables)

¡E CE marking for European countries (Class A.

Note: Class A with UTP cables)

¡E EN 55022: 1995 (Emission Standard)

¡E EN 61000-3-3: 1995

¡E EN 61000-3-2: 2000

¡E EN 55024: 1998 (Immunity Standards)

¡E EN 61000-4-2: 1995+A1: 1998

¡E EN 61000-4-3: 1996+A1: 1998

¡E EN 61000-4-4: 1995

¡E EN 61000-4-5: 1995

¡E EN 61000-4-6: 1996

¡E EN 61000-4-8: 1994

¡E EN 61000-4-11: 1994

¡E IEEE802.3: Hi-Pot Test (2250 VDC on all

Ethernet ports)

Safety Agency Certifications

¡E US UL 60950

¡E IEC 60950-1:2001; all national deviations

¡E EN 60950-1: 2001; all deviations

¡E CAN/CSA-C22.2 No. 60950-1-03

¡E NOM-019 SCFI, Mexico

¡E AS/NZ TS-001 and 60950:2000, Australia

¡E UL-AR, Argentina

¡E UL-GS Mark, Germany

¡E EN 60825-1 Laser, EN60825-2 Laser

¡E CDRH Laser

¡E China CCC

¡@

IEEE Standards

¡@

¡E IEEE 802.1D (STP)

¡E IEEE 802.1p (CoS)

¡E IEEE 802.1Q (VLANs)

¡E IEEE 802.1QinQ(VLAN stacking)

¡E IEEE 802.1ag (Connectivity Fault

Management)

¡E IEEE 802.1s (MSTP)

¡E IEEE 802.1w (RSTP)

¡E IEEE 802.1X (Port Based Network Access

Protocol)

¡E IEEE 802.3i (10BaseT)

¡E IEEE 802.3u (Fast Ethernet)

¡E IEEE 802.3x (Flow Control)

¡E IEEE 802.3z (Gigabit Ethernet)

¡E IEEE 802.3ab (1000BaseT)

¡E IEEE 802.3ac (VLAN Tagging)

¡E IEEE 802.3ad (Link Aggregation)

¡E IEEE 802.3af (Power-over-Ethernet)

¡E IEEE 802.3ae (10G Ethernet)

¡@

Environmental requirements

¡@

OPERATING TEMPERATURE:

¡E 32¢X to 113¢XF (0¢X to 45¢XC)

STORAGE TEMPERATURE:

¡E 14¢X to 158¢XF (-10¢X to 70¢XC)

HUMIDITY (OPERATING AND STORAGE):

¡E 5% to 95% non-condensing

¡@

IETF Standards

¡@

BGP

¡E RFC 1269/1657 BGP v3 & v4 MIB

¡E RFC 1403/1745 BGP/OSPF Interaction

¡E RFC 1771-1774/2842/2918/3392 BGP v4

¡E RFC 1965 BGP AS Confederations

¡E RFC 1966 BGP Route Reflection

¡E RFC 1997/1998 BGP Communities Attribute

¡E RFC 2042 BGP New Attribute

¡E RFC 2385 BGP MD5 Signature

¡E RFC 2439 BGP Route Flap Damping

¡E RFC 2796 BGP Route Reflection

¡E RFC 3065 BGP AS Confederations

OSPF

¡E RFC 1253/1850/2328 OSPF v2 & MIB

¡E RFC 1587/3101 OSPF NSSA Option

¡E RFC 1765 OSPF Database Overflow

¡E RFC 2154 OSPF MD5 Signature

¡E RFC 2370/3630 OSPF Opaque LSA

¡E RFC 3623 OSPF Graceful Restart

RIP

¡E RFC 1058 RIP v1

¡E RFC 1722/1723/2453/1724 RIP v2 & MIB

¡E RFC 1812/2644 IPv4 Router Requirement

¡E RFC 2080 RIPS ng

IS-IS

¡E RFC 1142 OSI IS-IS Intra-domain Routing

Protocol

¡E RFC 1195 Use of OSI IS-IS for routing in

TCP/IP & dual environments

¡E RFC 2763 Dynamic Hostname Exchange

for IS-IS

IP MULTICAST

¡E RFC 1075 DVMRP

¡E RFC 1112 IGMP v1

¡E RFC 2236/2933 IGMP v2 & MIB

¡E RFC 2362 PIM-SM

¡E RFC 2365 Multicast

¡E RFC 2715/2932 Multicast Routing MIB

¡E RFC 2934 PIM MIB for IPv4

¡E RFC 3376 IGMPv3

IPV6

¡E RFC 1886 DNS for IPv6

¡E RFC 2292/2373/2374/2460/2462 IPv6

¡E RFC 2461 NDP

¡E RFC 2463/2466 ICMP v6 & MIB

¡E RFC 2452/2454 IPv6 TCP/UDP MIB

¡E RFC 2464/2553/2893/3493/3513 IPv6

¡E RFC 3056 IPv6 Tunneling

¡E RFC 3542/3587 IPv6

MANAGEABILITY

¡E RFC 854/855 Telnet & Telnet options

¡E RFC 1155/2578-2580 SMI v1 & SMI v2

¡E RFC 1157/2271 SNMP

¡E RFC 1212/2737 MIB & MIB-II

¡E RFC 1213/2011-2013 SNMP v2 MIB

¡E RFC 1215 Convention for SNMP Traps

¡E RFC 1573/2233/2863 Private Interface MIB

¡E RFC 1643/2665 Ethernet MIB

¡E RFC 1901-1908/3416-3418 SNMP v2c

¡E RFC 2096 IP MIB

¡E RFC 2570-2576/3411-3415 SNMP v3

¡E RFC 2616 /2854 HTTP & HTML

¡E RFC 2667 IP Tunneling MIB

¡E RFC 2668/3636 IEEE 802.3 MAU MIB

¡E RFC 2674 VLAN MIB

SECURITY

¡E RFC 959/2640 FTP

¡E RFC 1321 MD5

¡E RFC 2104 HMAC Message Authentication

¡E RFC 2138/2865/2868/3575/2618

RADIUSAuthentication & Client MIB

¡E RFC 2139/2866/2867/2620 RADIUS

Accounting & Client MIB

¡E RFC 2228 step

¡E RFC 2284 PPP EAP

¡E RFC 2869/2869bis RADIUS Extension

QUALITY OF SERVICES

¡E RFC 896 Congestion control

¡E RFC 1122 Internet Hosts

¡E RFC 2474/2475/2597/3168/3246 DiffServ

¡E RFC 3635 Pause Control

OTHERS

¡E RFC 791/894/1024/1349 IP & IP / Ethernet

¡E RFC 792 ICMP

¡E RFC 768 UDP

¡E RFC 793/1156 TCP/IP & MIB

¡E RFC 826/903 ARP & Reverse ARP

¡E RFC 919/922 Broadcasting internet datagram

¡E RFC 925/1027 Multi LAN ARP / Proxy ARP

¡E RFC 950 Subnetting

¡E RFC 951 Bootp

¡E RFC 1151 RDP

¡E RFC 1191 Path MTU Discovery

¡E RFC 1256 ICMP Router Discovery

¡E RFC 1305/2030 NTP v3 & Simple NTP

¡E RFC 1493 Bridge MIB

¡E RFC 1518/1519 CIDR

¡E RFC 1541/1542/2131/3396/3442 DHCP

¡E RFC 1757/2819 RMON & MIB

¡E RFC 2131/3046 DHCP/BootP Relay

¡E RFC 2132 DHCP Options

¡E RFC 2251 LDAP v3

¡E RFC 2338/3768/2787 VRRP & MIB

¡E RFC 3060 Policy Core

¡E RFC 3176 sFlow

¡@

Product MTFB (hours) Power
Consumption
Heat Dissapation under
full load (Btu/hour)
Acoustic Level
(dB)***
PoE Models

OS6850-P24

153,497 324 279 under 44dB
OS6850-P24X 148,929 327 289 under 44dB
OS6850-P48 128,390 367 517 under 44dB
OS6850-P48X 119,750 387 584 under 44dB
Non-PoE Models
OS6850-24 200,421 55 188 under 44dB
OS6850-24X 191,695 58 198 under 44dB
OS6850-48 162,844 97 331 under 44dB
OS6850-48X 149,608 117 399 under 44dB
OS6850-U24X 207,199 119 406 under 44dB

¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank ¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºALCATEL - OS6850-P24 - ºô¸ô³]³Æ/ÀW¼eºÞ²z ,³Ì¦nªºALCATEL - Alcatel-Lucent OmniSwitch 6850 L3¸ô¥Ñ¥æ´«¾¹±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú
¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B


¡@
¡@

ServerBank¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m service@serverbank.com.tw
¹q¸Ü(02)8969-0901 ¶Ç¯u(02)2253-9016 ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó

¡@
¡@