º¶>
ºô¸ô³]³Æ/ÀW¼eºÞ²z >>ÂsÄý©Ò¦³ALCATELºô¸ô³]³Æ/ÀW¼eºÞ²z
ALCATEL
Alcatel-Lucent OmniSwitch 6855 Ethernet Hardened LAN Switch OS6855-U10
«¬¸¹¡GOS6855-U10
°Ñ¦Ò°â»ù¡G½Ð¥ß§Y¨Ó¹q ¤O±ô¸ê°T ( »ù®æ¯}Ãa¦æ±¡¡I¨Ó¹q¬¢¸ß)
ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶WÈÀu´fªºALCATEL - OS6855-U10 - ºô¸ô³]³Æ/ÀW¼eºÞ²z
³Ì¦nªºALCATEL - Alcatel-Lucent OmniSwitch 6855 Ethernet Hardened LAN Switch OS6855-U10±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´Úºô¸ô³]³Æ/ÀW¼eºÞ²z
Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!
ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I
¤ñServerBank§ó«K©y¡H
¡@
²£«~¯S¦â
Wide choice of models offering different port densities:
10, 14, 24GigE, copper and support variety of fiber
types: single-mode, multi-mode, short and long haul
optics allowing distances of up to 70 km
ALCATEL Alcatel-Lucent OmniSwitch 6855 Ethernet Hardened LAN Switch OS6855-U10 - ServerBank¸ê°T±ÄÁʺô OS6855-U10 ºô¸ô³]³Æ/ÀW¼eºÞ²z
¡@
²£«~³W®æ
Simplified manageability and ease of use
•
Intuitive
Alcatel-Lucent command line input (CLI)
•
Intuitive
Alcatel-Lucent command line input (CLI)
•
Full
configuration through SNMP- v1/v2/v3
•
Full
configuration through SNMP- v1/v2/v3
•
Extensive user
manuals with examples
•
Remote telnet
management or secure shell access using SSH
•
Out-of-bound
management through console
•
Secured file
upload using SFTP or SCP
•
Dual image and
dual configuration file storage provides backup
•
Human readable
ASCII based configuration files for offline editing and
bulk configuration
•
BootP/DHCP
client allows auto-config of switch IP information to
simplify deployment
•
Auto-negotiating
10/100/1000 ports automatically configure port speed and
duplex setting
•
Auto MDI/MDIX
automatically configures transmit and receive signals to
support straight through and crossover cabling
•
DHCP relay to
forward client requests to a DHCP server
•
Integration with
SNMP manager OmniVista for network-wide management
•
Integration with
SNMP manager OmniVista for network-wide management
•
Network Time
Protocol (NTP) client for network wide time synchronization
•
802.1AB ¡V Link
Layer Discovery Protocol (LLDP) with MED extensions
•
802.1AB ¡V Link
Layer Discovery Protocol (LLDP) with MED extensions
•
Auto QoS for
switch management traffic as well as traffic from
Alcatel-Lucent IP phones
Troubleshooting
•
Port-based
mirroring
•
Remote-port
mirroring
•
Policy-based
mirroring - Allows selection of the type of traffic to
mirror by using QoS policies
•
Port monitoring
feature that allows capture of Ethernet packets to a file,
or for on-screen display to assist in troubleshooting
•
sFlow v5 support
to monitor and effectively control and manage the network
usage
•
Local (on the
flash) and remote logging (Syslog)
•
IP tools: ping
and trace
•
802.1ag Ethernet
OAM (L2 ping and trace)
High
availability
•
Ring Rapid
Spanning Tree optimized for ring topology to provide less
than 100ms convergence time
•
802.1w Rapid
Recovery Spanning Tree allows sub-second failover to
redundant link
•
Alcatel-Lucent
per-VLAN spanning tree (1x1)
•
802.1D spanning
tree for loop free topology and link redundancy
•
802.1s multiple
spanning tree
•
Fast forwarding
mode on user ports to bypass 30-second delay for spanning
tree
•
Static and
802.3ad dynamic link aggregation that supports automatic
configuration of link aggregates with other switches
•
Broadcast storm
control
•
BPDU blocking ¡V
automatically shuts down switch ports being used as user
ports if a spanning tree BPDU packet is seen
•
Unidirectional
Link Detection Protocol (UDLD) for detecting one way
connections
•
Graceful
Protocol Restart ¡V OSFP
•
VRRP
•
Redundant 1:1
power provided by the OmniSwitch 6855 backup power supplies
Quality
of Service
•
Priority queues:
eight hardware-based queues per port
•
Traffic
prioritization: Flow-based QoS with internal and external
(a.k.a., remarking) prioritization
•
Bandwidth
management: flow based bandwidth management, ingress
policing/egress shaping and port based egress shaping
•
Queue
management: Random Early Detect/Discard (RED), configurable
de-queuing algorithm; strict priority, weighted and deficit
round robin.
Advanced
security
•
MAC limiting ¡V
learned port security
•
Allowed MAC
addresses
•
802.1X
multi-client, multi-VLAN support for per client
authentication and VLAN assignment
•
IEEE 802.1X with
group mobility
•
IEEE 802.1X with
MAC based authentication, group mobility or ¡§guest¡¨
VLAN support
•
802.1x with VoIP
VLAN support
•
MAC-based
authentication for non-802.1X host
•
Authenticated
VLAN
•
Captive portal ¡V
an embedded web portal for user authentication .*
•
Automatic
quarantine
•
PKI
authentication for SSH access
•
Support for host
integrity check and remediation VLAN
•
Support for
Alcatel-Lucent OmniVista 2770 Quarantine Manager and
quarantine VLAN
•
Traffic Anomaly
Detection (TAD) ¡V embedded
•
RADIUS and LDAP
admin authentication
•
TACACS+ client
allows for authentication authorization and accounting with
a remote TACACS+ server
•
Secure Shell (SSH),
Secure Socket Layer (SSL) for HTTPS access and SNMPv3
for encrypted remote management communication
•
Access control
lists (ALC) to filter out unwanted traffic including denial
of service attacks
•
Flow based
filtering in hardware (L1-L4); port based, VLAN based ACLs
•
ACL editing
•
Support of
Microsoft Network Access Protection
•
Switch protocol
security
¡@
MD5 for RIPv2,
OSPFv2 and SNMPv3
¡@
¬
SSH for secure
CLI session with PKI support
¡@
¬
SSL for secure
HTTP session
Metro
Ethernet Services
•
QinQ (VLAN
stacking) - 802.1ad ¡V provider bridge
•
VLAN translation
•
Ethernet OAM
compliant with 802.1ag version 7.0
•
Ethernet OAM
compliant with 802.3ah*
•
DHCP Snooping,
DHCP IP Spoof protection
•
DHCP Option 82 ¡V
relay agent information
•
MEF 9 and 14
certified
L3
routing protocols (IPv4 and IPv6)
¡@
IP
routing
¡@
¬
Static routing
¡@
¬
RIP v1 and v2,
RIPng
¡@
¬
OSPF v2, v3
¡@
¬
GRE tunnels
¡@
¬
IP/IP tunnels
Multicast
•
IGMP v1/v2/v3
•
IGMP snooping,
MLD snooping
•
PIM-SM, PIM-DM
•
DVMRP
Network
protocol
•
TCP/IP stack
•
ARP
•
DHCP relay
•
Generic UDP
relay per VLAN
¡@
Layer-3 routing
(IPX): IP routing, static routing, RIP/SAP
Indicators
•
Per port LEDs:
link / activity /PoE
•
System LEDs: OK
(switch HW/SW status)
•
PS1/PS2: primary
and/or redundant power
supply status
Compliance and Certification Commercial
¡@
EMI/EMC
•
FCC CRF Title 47
Subpart B (Class A and Class B* limits)
•
VCCI (Class A
and Class B* limits
•
AS/NZS 3548
(Class A and Class B*)
•
CE marking for
European countries (Class A and Class B*)
•
EN 55022: 2006
(Emission Standard)
•
EN 61000-3-3:
1995
•
EN 61000-3-2:
2006
•
EN 55024: 1998
(Immunity Standards)
¡@
EN 61000-4-2:
1995+A1: 1998
¡@
EN 61000-4-3:
1996+A1: 1998
¡@
EN 61000-4-4:
1995
¡@
EN 61000-4-5:
1995
¡@
EN 61000-4-6:
1996
¡@
EN 61000-4-8:
1994
¡@
EN 61000-4-11:
1994
•
IEEE802.3:
Hi-Pot Test (2250 VDC on all
Ethernet ports)
Industrial
•
IEC 60870-2-2
(operational temperature)
•
IEC 60068-2-1
(temperature type test ¡V cold)
•
IEC 60068-2-2
(temperature type test ¡V hot)
•
IEC 60721-3-1:
Class 1K5 (storage temperature)
•
IEC 68-2-30 95%
non-condensing humidity
•
IEC 60255-21-2
(mechanical shock)
•
IEC 60255-21-1
(vibration)
¡@
EMI/EMC
•
EN 61131-2
•
EN 55024: 1998
(Immunity Standards)
¡@
IEC 61000-4-3
¡@
IEC 61000-4-12
¡@
IEC 61000-4-16
¡@
IEC 61000-4-17
¡@
IEC 61000-4-29
•
IEC 60255-5
•
IEC 61850-3
(Electric power Substations)
•
IEEE 1613
(C37.90.x)
¡@
C37.90.3 (ESD)
¡@
C37.90.2
(Radiated RFI)
¡@
IEEE1613
C37.90.1 (Fast Transient)
¡@
IEEE1613
C37.90.1 ( Oscillatory)
¡@
IEEE1613 C37.90
(H.V. Impulse)
¡@
IEEE1613 C37.90
(Dielectric Strength)
NEBs **
•
GR-63-CORE
(temp, humidity, altitude, contamination)
•
GR-1089-CORE
Issue 4 (section 2-3)
•
GR-1089-CORE
Issue 4 (section 3.2, 4-10)
Military
•
MIL-STD-810F
(shock and vibration)
•
MIL-STD-901D
(shock) **
•
MIL-STD-167-1
(vibration)**
•
MIL-STD-810F,
Methods 500, 501, 502, 503, 504, 505, 506, 507, 508, 509,
510, 512, 514, 515, 516, 520, 521 **
•
MIL-STD-461E:
CE101, CE102, CS101, CS114, CS115, CS116, RE101, RE 102,
RS101, RS103 **
Safety
Agency Certifications
•
US UL 60950
•
IEC
60950-1:2001; all national deviations
•
EN 60950-1:
2001; all deviations
•
CAN/CSA-C22.2
No. 60950-1-03
•
NOM-019 SCFI,
Mexico
•
AS/NZ TS-001 and
60950:2000, Australia
•
UL-AR, Argentina
•
UL-GS Mark,
Germany
•
EN 60825-1
Laser, EN60825-2 Laser
•
CDRH Laser
Safety
Agency Certifications
•
US UL 60950
•
IEC
60950-1:2001; all national deviations
•
EN 60950-1:
2001; all deviations
•
CAN/CSA-C22.2
No. 60950-1-03
•
NOM-019 SCFI,
Mexico
•
AS/NZ TS-001 and
60950:2000, Australia
•
UL-AR, Argentina
•
UL-GS Mark,
Germany
•
EN 60825-1
Laser, EN60825-2 Laser
•
CDRH Laser
IEEE
¡@
Standards
•
IEEE 802.1D (STP)
•
IEEE 802.1p (CoS)
•
IEEE 802.1Q (VLANs)
•
IEEE 802.1ad
(Provider Bridge) QinQ(VLAN stacking)
•
IEEE 802.1ag
(Connectivity Fault Management)
•
IEEE 802.1s (MSTP)
•
IEEE 802.1w (RSTP)
•
IEEE 802.1X
(Port Based Network Access Protocol)
•
IEEE 802.3i
(10BaseT)
•
IEEE 802.3u
(Fast Ethernet)
•
IEEE 802.3x
(Flow Control)
•
IEEE 802.3z
(Gigabit Ethernet)
•
IEEE 802.3ab
(1000BaseT)
•
IEEE 802.3ac (VLAN
Tagging)
•
IEEE 802.3ad
(Link Aggregation)
•
IEEE 802.3af
(Power-over-Ethernet)
IETF
Standards
¡@
IPv4
•
RFC 2003 IP/IP
tunneling
•
RFC 2784 GRE
tunneling
PoE models
OS6855-14
Two SFP fiber ports 100/1000Base-X
Operating temperature:
-40¢XC to +70¢XC
OS6855-24
Fiber models
OS6855-U10
OS6855-U24
¡D¥»¤å¥óªº¸ê°TY¦³×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ùY¦³»~¡A¥Hì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨äì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C
º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á!
ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶WÈÀu´fªºALCATEL - OS6855-U10 - ºô¸ô³]³Æ/ÀW¼eºÞ²z
,³Ì¦nªºALCATEL - Alcatel-Lucent OmniSwitch 6855 Ethernet Hardened LAN Switch OS6855-U10±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§ÚÌ·|¬°±z¦Vì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú̳£¥i¼u©Ê°t¦X±zªº»Ýn³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G
1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»¶ÁʶR¸ß»ù§ÚÌ·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯uq³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨qÁʵ{§Ç¡A§ÚÌ·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú̦¬¨ì±zq³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±zt¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡GY²£«~¥»¨·å²«©Î¹B°e¹Lµ{¾ÉP·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥Hì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C¡@
¤O±ô¸ê°T ServerBank Inc. ²¤¶
¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G
»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶Û¡B¥xÆWªFªÛ¡B¥xÆW^¸â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B
¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B
ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B
¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B
Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B
¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B
´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B¸ºÐ¼s¼½¡B·¼é°Û¤ù¡B®É³ø©P¥Z¡B
±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B
²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡Bì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°
¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B
ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B
¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B
¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤±]±¶¹B¡B¥xÆW´¼¼z¥d¡B
¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½^¡B¿ßÀYÆN
©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B
x¤è¡G ªÅx¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B
¡@
ServerBank ¥Ñ¤O±ô¸ê°TªÑ¥÷¦³¤½¥q«Ø¸m@
·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó
¹q¸Ü: (02)8969-0901
service@serverbank.com.tw
www.ServerBank.com.tw
ServerBank ¤O±ô¸ê°TServerBank¸ê°T±ÄÁʺô >
ºô¸ô³]³Æ/ÀW¼eºÞ²z
¡@
²£«~¯S¦â
Wide choice of models offering different port densities:
10, 14, 24GigE, copper and support variety of fiber
types: single-mode, multi-mode, short and long haul
optics allowing distances of up to 70 km
ALCATEL Alcatel-Lucent OmniSwitch 6855 Ethernet Hardened LAN Switch OS6855-U10 - ServerBank¸ê°T±ÄÁʺô OS6855-U10 ºô¸ô³]³Æ/ÀW¼eºÞ²z
¡@
²£«~³W®æ
Simplified manageability and ease of use
•
Intuitive
Alcatel-Lucent command line input (CLI)
•
Intuitive
Alcatel-Lucent command line input (CLI)
•
Full
configuration through SNMP- v1/v2/v3
•
Full
configuration through SNMP- v1/v2/v3
•
Extensive user
manuals with examples
•
Remote telnet
management or secure shell access using SSH
•
Out-of-bound
management through console
•
Secured file
upload using SFTP or SCP
•
Dual image and
dual configuration file storage provides backup
•
Human readable
ASCII based configuration files for offline editing and
bulk configuration
•
BootP/DHCP
client allows auto-config of switch IP information to
simplify deployment
•
Auto-negotiating
10/100/1000 ports automatically configure port speed and
duplex setting
•
Auto MDI/MDIX
automatically configures transmit and receive signals to
support straight through and crossover cabling
•
DHCP relay to
forward client requests to a DHCP server
•
Integration with
SNMP manager OmniVista for network-wide management
•
Integration with
SNMP manager OmniVista for network-wide management
•
Network Time
Protocol (NTP) client for network wide time synchronization
•
802.1AB ¡V Link
Layer Discovery Protocol (LLDP) with MED extensions
•
802.1AB ¡V Link
Layer Discovery Protocol (LLDP) with MED extensions
•
Auto QoS for
switch management traffic as well as traffic from
Alcatel-Lucent IP phones
Troubleshooting
•
Port-based
mirroring
•
Remote-port
mirroring
•
Policy-based
mirroring - Allows selection of the type of traffic to
mirror by using QoS policies
•
Port monitoring
feature that allows capture of Ethernet packets to a file,
or for on-screen display to assist in troubleshooting
•
sFlow v5 support
to monitor and effectively control and manage the network
usage
•
Local (on the
flash) and remote logging (Syslog)
•
IP tools: ping
and trace
•
802.1ag Ethernet
OAM (L2 ping and trace)
High
availability
•
Ring Rapid
Spanning Tree optimized for ring topology to provide less
than 100ms convergence time
•
802.1w Rapid
Recovery Spanning Tree allows sub-second failover to
redundant link
•
Alcatel-Lucent
per-VLAN spanning tree (1x1)
•
802.1D spanning
tree for loop free topology and link redundancy
•
802.1s multiple
spanning tree
•
Fast forwarding
mode on user ports to bypass 30-second delay for spanning
tree
•
Static and
802.3ad dynamic link aggregation that supports automatic
configuration of link aggregates with other switches
•
Broadcast storm
control
•
BPDU blocking ¡V
automatically shuts down switch ports being used as user
ports if a spanning tree BPDU packet is seen
•
Unidirectional
Link Detection Protocol (UDLD) for detecting one way
connections
•
Graceful
Protocol Restart ¡V OSFP
•
VRRP
•
Redundant 1:1
power provided by the OmniSwitch 6855 backup power supplies
Quality
of Service
•
Priority queues:
eight hardware-based queues per port
•
Traffic
prioritization: Flow-based QoS with internal and external
(a.k.a., remarking) prioritization
•
Bandwidth
management: flow based bandwidth management, ingress
policing/egress shaping and port based egress shaping
•
Queue
management: Random Early Detect/Discard (RED), configurable
de-queuing algorithm; strict priority, weighted and deficit
round robin.
Advanced
security
•
MAC limiting ¡V
learned port security
•
Allowed MAC
addresses
•
802.1X
multi-client, multi-VLAN support for per client
authentication and VLAN assignment
•
IEEE 802.1X with
group mobility
•
IEEE 802.1X with
MAC based authentication, group mobility or ¡§guest¡¨
VLAN support
•
802.1x with VoIP
VLAN support
•
MAC-based
authentication for non-802.1X host
•
Authenticated
VLAN
•
Captive portal ¡V
an embedded web portal for user authentication .*
•
Automatic
quarantine
•
PKI
authentication for SSH access
•
Support for host
integrity check and remediation VLAN
•
Support for
Alcatel-Lucent OmniVista 2770 Quarantine Manager and
quarantine VLAN
•
Traffic Anomaly
Detection (TAD) ¡V embedded
•
RADIUS and LDAP
admin authentication
•
TACACS+ client
allows for authentication authorization and accounting with
a remote TACACS+ server
•
Secure Shell (SSH),
Secure Socket Layer (SSL) for HTTPS access and SNMPv3
for encrypted remote management communication
•
Access control
lists (ALC) to filter out unwanted traffic including denial
of service attacks
•
Flow based
filtering in hardware (L1-L4); port based, VLAN based ACLs
•
ACL editing
•
Support of
Microsoft Network Access Protection
•
Switch protocol
security
¡@
MD5 for RIPv2,
OSPFv2 and SNMPv3
¡@
¬
SSH for secure
CLI session with PKI support
¡@
¬
SSL for secure
HTTP session
Metro
Ethernet Services
•
QinQ (VLAN
stacking) - 802.1ad ¡V provider bridge
•
VLAN translation
•
Ethernet OAM
compliant with 802.1ag version 7.0
•
Ethernet OAM
compliant with 802.3ah*
•
DHCP Snooping,
DHCP IP Spoof protection
•
DHCP Option 82 ¡V
relay agent information
•
MEF 9 and 14
certified
L3
routing protocols (IPv4 and IPv6)
¡@
IP
routing
¡@
¬
Static routing
¡@
¬
RIP v1 and v2,
RIPng
¡@
¬
OSPF v2, v3
¡@
¬
GRE tunnels
¡@
¬
IP/IP tunnels
Multicast
•
IGMP v1/v2/v3
•
IGMP snooping,
MLD snooping
•
PIM-SM, PIM-DM
•
DVMRP
Network
protocol
•
TCP/IP stack
•
ARP
•
DHCP relay
•
Generic UDP
relay per VLAN
¡@
Layer-3 routing
(IPX): IP routing, static routing, RIP/SAP
Indicators
•
Per port LEDs:
link / activity /PoE
•
System LEDs: OK
(switch HW/SW status)
•
PS1/PS2: primary
and/or redundant power
supply status
Compliance and Certification Commercial
¡@
EMI/EMC
•
FCC CRF Title 47
Subpart B (Class A and Class B* limits)
•
VCCI (Class A
and Class B* limits
•
AS/NZS 3548
(Class A and Class B*)
•
CE marking for
European countries (Class A and Class B*)
•
EN 55022: 2006
(Emission Standard)
•
EN 61000-3-3:
1995
•
EN 61000-3-2:
2006
•
EN 55024: 1998
(Immunity Standards)
¡@
EN 61000-4-2:
1995+A1: 1998
¡@
EN 61000-4-3:
1996+A1: 1998
¡@
EN 61000-4-4:
1995
¡@
EN 61000-4-5:
1995
¡@
EN 61000-4-6:
1996
¡@
EN 61000-4-8:
1994
¡@
EN 61000-4-11:
1994
•
IEEE802.3:
Hi-Pot Test (2250 VDC on all
Ethernet ports)
Industrial
•
IEC 60870-2-2
(operational temperature)
•
IEC 60068-2-1
(temperature type test ¡V cold)
•
IEC 60068-2-2
(temperature type test ¡V hot)
•
IEC 60721-3-1:
Class 1K5 (storage temperature)
•
IEC 68-2-30 95%
non-condensing humidity
•
IEC 60255-21-2
(mechanical shock)
•
IEC 60255-21-1
(vibration)
¡@
EMI/EMC
•
EN 61131-2
•
EN 55024: 1998
(Immunity Standards)
¡@
IEC 61000-4-3
¡@
IEC 61000-4-12
¡@
IEC 61000-4-16
¡@
IEC 61000-4-17
¡@
IEC 61000-4-29
•
IEC 60255-5
•
IEC 61850-3
(Electric power Substations)
•
IEEE 1613
(C37.90.x)
¡@
C37.90.3 (ESD)
¡@
C37.90.2
(Radiated RFI)
¡@
IEEE1613
C37.90.1 (Fast Transient)
¡@
IEEE1613
C37.90.1 ( Oscillatory)
¡@
IEEE1613 C37.90
(H.V. Impulse)
¡@
IEEE1613 C37.90
(Dielectric Strength)
NEBs **
•
GR-63-CORE
(temp, humidity, altitude, contamination)
•
GR-1089-CORE
Issue 4 (section 2-3)
•
GR-1089-CORE
Issue 4 (section 3.2, 4-10)
Military
•
MIL-STD-810F
(shock and vibration)
•
MIL-STD-901D
(shock) **
•
MIL-STD-167-1
(vibration)**
•
MIL-STD-810F,
Methods 500, 501, 502, 503, 504, 505, 506, 507, 508, 509,
510, 512, 514, 515, 516, 520, 521 **
•
MIL-STD-461E:
CE101, CE102, CS101, CS114, CS115, CS116, RE101, RE 102,
RS101, RS103 **
Safety
Agency Certifications
•
US UL 60950
•
IEC
60950-1:2001; all national deviations
•
EN 60950-1:
2001; all deviations
•
CAN/CSA-C22.2
No. 60950-1-03
•
NOM-019 SCFI,
Mexico
•
AS/NZ TS-001 and
60950:2000, Australia
•
UL-AR, Argentina
•
UL-GS Mark,
Germany
•
EN 60825-1
Laser, EN60825-2 Laser
•
CDRH Laser
Safety
Agency Certifications
•
US UL 60950
•
IEC
60950-1:2001; all national deviations
•
EN 60950-1:
2001; all deviations
•
CAN/CSA-C22.2
No. 60950-1-03
•
NOM-019 SCFI,
Mexico
•
AS/NZ TS-001 and
60950:2000, Australia
•
UL-AR, Argentina
•
UL-GS Mark,
Germany
•
EN 60825-1
Laser, EN60825-2 Laser
•
CDRH Laser
IEEE
¡@
Standards
•
IEEE 802.1D (STP)
•
IEEE 802.1p (CoS)
•
IEEE 802.1Q (VLANs)
•
IEEE 802.1ad
(Provider Bridge) QinQ(VLAN stacking)
•
IEEE 802.1ag
(Connectivity Fault Management)
•
IEEE 802.1s (MSTP)
•
IEEE 802.1w (RSTP)
•
IEEE 802.1X
(Port Based Network Access Protocol)
•
IEEE 802.3i
(10BaseT)
•
IEEE 802.3u
(Fast Ethernet)
•
IEEE 802.3x
(Flow Control)
•
IEEE 802.3z
(Gigabit Ethernet)
•
IEEE 802.3ab
(1000BaseT)
•
IEEE 802.3ac (VLAN
Tagging)
•
IEEE 802.3ad
(Link Aggregation)
•
IEEE 802.3af
(Power-over-Ethernet)
IETF
Standards
¡@
IPv4
•
RFC 2003 IP/IP
tunneling
•
RFC 2784 GRE
tunneling
PoE models
OS6855-14
Two SFP fiber ports 100/1000Base-X
Operating temperature:
-40¢XC to +70¢XC
OS6855-24
Fiber models
OS6855-U10
OS6855-U24
¡D¥»¤å¥óªº¸ê°TY¦³×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ùY¦³»~¡A¥Hì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨äì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C
º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á!
ServerBank ¤O±ô¸ê°Tµ¹§A³Ì¶WÈÀu´fªºALCATEL - OS6855-U10 - ºô¸ô³]³Æ/ÀW¼eºÞ²z
,³Ì¦nªºALCATEL - Alcatel-Lucent OmniSwitch 6855 Ethernet Hardened LAN Switch OS6855-U10±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§ÚÌ·|¬°±z¦Vì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú̳£¥i¼u©Ê°t¦X±zªº»Ýn³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G
1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»¶ÁʶR¸ß»ù§ÚÌ·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯uq³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨qÁʵ{§Ç¡A§ÚÌ·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú̦¬¨ì±zq³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±zt¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡GY²£«~¥»¨·å²«©Î¹B°e¹Lµ{¾ÉP·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥Hì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C
¤O±ô¸ê°T ServerBank Inc. ²¤¶
¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G
»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶Û¡B¥xÆWªFªÛ¡B¥xÆW^¸â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B
¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B
ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B
¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B
Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B
¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B
´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B¸ºÐ¼s¼½¡B·¼é°Û¤ù¡B®É³ø©P¥Z¡B
±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B
²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡Bì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°
¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B
ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B
¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B
¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤±]±¶¹B¡B¥xÆW´¼¼z¥d¡B
¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½^¡B¿ßÀYÆN
©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B
x¤è¡G ªÅx¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B
¡@
ServerBank¥Ñ¤O±ô¸ê°TªÑ¥÷¦³¤½¥q«Ø¸m service@serverbank.com.tw
¹q¸Ü(02)8969-0901 ¶Ç¯u(02)2253-9016 ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó
¡@
¡@