NetApp FAS2500 Series - ServerBank¸ê°T±ÄÁʺô FAS2500 Series Àx¦s³]³Æ/³Æ¥÷¤è®×
¡@
·s¼Wºô¶1
¡@ |
FAS2554 |
FAS2552 |
FAS2520 |
¡@ |
Single Controller |
Dual Controller |
Single Controller |
Dual Controller |
Single Controller |
Dual Controller |
Max. Raw Capacity |
864TB |
864TB |
759TB |
759TB |
504TB |
504TB |
Internal Drives |
24 |
24 |
24 |
24 |
12 |
12 |
Supported Internal Drives |
Performance HDD |
N/A |
600GB, 900GB, 1.2TB |
600GB, 900GB, 1.2 TB |
Capacity HDD |
2TB, 3TB, 4TB,6TB |
N/A |
2TB, 3TB, 4TB,6TB |
SSD |
200GB, 400GB, 800GB |
200GB, 400GB, 800GB, 1.6TB |
200GB, 400GB, 800GB, 1.6TB |
Self-encrypting Drives |
4TB at 7.2K RPM AES-256, FIPS 140-2 compliant |
900GB at 10K RPM, 800GB SSD AES-256, FIPS 140-2 compliant |
900GB at 10KRPM, 4TB at 7.2K RPM AES-256, FIPS 140-2 compliant |
Max. Drives (Internal + External) |
144 |
144 |
144 |
144 |
84 |
84 |
ECC Memory |
18GB |
36GB |
18GB |
36GB |
18GB |
36GB |
Controller Form Factor |
1 or 2 controllers in a single 4U chassis |
1 or 2 controllers in a single 2U chassis |
1 or 2 controllers in a single 2U chassis |
Maximum Flash Pool |
16TB[1] |
16TB[1] |
16TB[1] |
16TB[1] |
16TB[1] |
16TB[1] |
NVMEM/NVRAM |
2GB |
4GB |
2GB |
4GB |
2GB |
4GB |
Onboard I/O: UTA 2 (8Gb FC/16Gb FC/FCoE/10GbE/1GbE[2]) |
4 [3] |
8 [3] |
4 [3] |
8 [3] |
N/A |
N/A |
Onboard I/O:
10G Base-T |
N/A |
N/A |
N/A |
N/A |
4 [4] |
8 [4] |
Onboard I/O: 6Gb SAS |
2 |
4 |
2 |
4 |
2 |
4 |
Onboard I/O: GbE |
2 |
4 |
2 |
4 |
2 |
4 |
Notes
[1] 16TB for Data ONTAP®
8.3, 4TB for Data ONTAP 8.2 (cluster mode and 7-mode).
[2] 1GbE optical and copper
SFP support starts with the release of Data ONTAP 8.3.1RC
[3] FAS2552 and FAS2554
onboard UTA2 ports can be configured as either 8Gb/16Gb FC port pair or
10GbE/1GbE port pair and mixed combinations.
[4] FAS2520 onboard ports
are 10GBASE-T only that can autorange to 1GbE.
Specifications for Scale-Out Configurations (Hybrid and Disk-Only
Configurations)
¡@ |
FAS2554 |
FAS2552 |
FAS2520 |
NAS/SAN Scale-out |
1¡V8 nodes (4 HA pairs) |
1¡V4 nodes (2 HA pairs) |
Maximum Drives |
576 |
576 |
168 |
Maximum Raw Capacity |
3.5PB |
3.0PB |
1PB |
Maximum Flash Pool |
64TB |
64TB |
32TB |
Maximum Memory |
144GB |
144GB |
72GB |
Cluster Interconnect |
10GbE |
10G Base-T |
¡@ |
FAS2554 |
FAS2552 |
FAS2520 |
Storage Protocols Supported |
FAS2552 / FAS2554 = FC; FCoE; iSCSI; NFS; pNFS; CIFS/SMB
FAS2520 = iSCSI; NFS; pNFS; CIFS/SMB
¡@ |
OS Version |
Data ONTAP® 8.2.2 or later |
High-Availability Features |
Alternate Control Path (ACP);
Ethernet-based service processor and
Data ONTAP management interface; redundant hot-swappable
controllers, cooling fans, and power supplies |
Supported Configurations |
Cluster Configurations
- Single-node cluster
- Two-node switchless cluster
- Two-node switched cluster
- Clusters of HA pairs
7-Mode Configurations
Controllers: Single
controller; active-active
controllers in an HA pair; active-passive
controllers in an HA pair
Back-End Disks: Single
path with single controller or HA pair; dual path with single
controller MP-HA with HA pair (best practice) |
Disk Shelves Supported |
DS2246 (2U; 24 drives, 2.5" SFF)
DS4246 (4U; 24 drives, 3.5" LFF)
For complete details on expansion disk shelves and supported media
in those shelves, refer to theNetApp
Disk Shelves and Storage Media web
page. |
Maximum RAID Group Sizes |
RAID 6 (RAID-DP®)
- SAS, SSD, and FC: 28 (26 data
disks plus 2 parity disks)
- SATA: 20 (18 data disks plus 2
parity disks)
RAID 4
- SAS, SSD, and FC: 14 (13 data
disks plus 1 parity disk)
- SATA: 7 (6 data disks plus 1
parity disk)
RAID 6 + RAID 1 or RAID 4 + RAID 1 (SyncMirror®) |
Host/Client Operating Systems Supported |
Windows® 2000, Windows Server® 2003, Windows Server 2008, Windows
Server 2012, Windows XP, Linux®, Oracle® Solaris, AIX, HP-UX, Mac®
OS, VMware®, ESX |
Max. Number of LUNs |
2048 per controller |
Number of Supported Hosts |
- Up to 6 ports per controller
configured as front-end (host) connectivity ports
- Up to 12 directly connected
servers per active-active configuration
- Connected hosts per HA pair: Up to
512 SAN connected servers
|
FlexVol Volumes |
Up to 1,000 per controller |
Snapshot® Copies |
Up to 255,000 per controller |
Maximum Volume Size |
60TB |
Maximum Aggregate Size |
120TB |
System
Environmental Specifications
¡@ |
FAS2554 |
FAS2552 |
FAS2520 |
Thermal Rating |
1,948 BTU (typical)
2,044 BTU (worst case) |
1,218 BTU (typical)
1,737 BTU (worst case) |
1,164 BTU (typical)
1,843 BTU (worst case) |
Weight[1] |
111.3 lbs |
55.4 lbs |
58.6 lbs |
Height |
7" (17.9 cm), fits into 4U space |
3.35" (8.5 cm), fits into 2U space |
3.45" (8.76 cm), fits into 2U space |
Width |
19" IEC rack-compliant (17.6", 44.7 cm) |
Depth (without cable management brackets) |
22" (56 cm) |
19" (48 cm) |
20" (50.8 cm) |
Operating Temperature, Altitude, and Relative Humidity |
50¢XF to 104¢XF (10¢XC to 40¢XC); at ≤ 3,000m (at ≤ 10,000) elevation;
20% to 80% relative humidity, noncondensing |
Nonoperating Temperature and Relative Humidity |
-40¢XF to 158¢XF (-40¢XC to 70¢XC); at ≤ 12,192m (at ≤ 40,000) typical
of unconditioned airplane cargo bay, 8% to 80% relative humidity,
noncondensing, in original container |
Operating Acoustic Noise |
FAS2520:
- Declared sound power (LwAd) per
ISO 9296: 6.2 Bel
- Sound pressure (LpAm) (bystander
positions): 49.6 dB
FAS2552:
- Declared sound power (LwAd) per
ISO 9296: 6.2 Bel
- Sound pressure (LpAm) (bystander
positions): 49.6 dB
FAS2554:
- Declared sound power (LwAd) per
ISO 9296: 6.1 Bel
- Sound pressure (LpAm) (bystander
positions): 49.6 dB
|
Compliance |
RoHS-compliant (PDF) |
Safety/Emissions/Immunity |
Safety: EN
60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national
deviations), EN60825-1, IRAM, CU, BIS, BSMI, SONCAP, NRCS LOA (South
Africa)
Emissions/Immunity: FCC
Part 15 Class A, ICES-03, CE, KCC, VCCI, AS/NZS CISPR 22, EN55022,
EN55024, EN61000-3-2, EN61000-3-3, SABS COC (South Africa), BSMI |
|
¡D¥»¤å¥óªº¸ê°TY¦³×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ùY¦³»~¡A¥Hì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨äì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C
º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á!
ServerBank ¤O±ô¸ê°Tµ¹§A³Ì¶WÈÀu´fªºNetApp - FAS2500 Series - Àx¦s³]³Æ/³Æ¥÷¤è®×
,³Ì¦nªºNetApp - FAS2500 Series±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
|
¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§ÚÌ·|¬°±z¦Vì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú̳£¥i¼u©Ê°t¦X±zªº»Ýn³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G
1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901 |
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»¶ÁʶR¸ß»ù§ÚÌ·|¥ß§Y»P±zÁpô! |
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw |
|
¥I´Ú¤è¦¡¡G¦p«È¤á¬°º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C |
¶Ç¯uq³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨qÁʵ{§Ç¡A§ÚÌ·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{q³æ¡C |
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú̦¬¨ì±zq³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C |
°e³f¤è¦¡¡G(1) ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C |
°e³f½d³ò¡G¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±zt¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C |
°â«áªA°È¡GY²£«~¥»¨·å²«©Î¹B°e¹Lµ{¾ÉP·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C |
«O©T¬Fµ¦¡G ¹ê»Ú¥Hì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C |
¤O±ô¸ê°T ServerBank Inc. ²¤¶
¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G
»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶Û¡B¥xÆWªFªÛ¡B¥xÆW^¸â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B
¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B
ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B
¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B
Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B
¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B
´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B¸ºÐ¼s¼½¡B·¼é°Û¤ù¡B®É³ø©P¥Z¡B
±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B
²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡Bì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°
¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B
ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B
¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B
¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤±]±¶¹B¡B¥xÆW´¼¼z¥d¡B
¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½^¡B¿ßÀYÆN
©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B
x¤è¡G ªÅx¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B
|
|
|
|
|
|
|