Technology |
Standards |
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3ab for 1000BaseT(X)
IEEE 802.3z for 1000BaseX
IEEE 802.3x for Flow Control
IEEE 802.1D-2004 for Spanning Tree Protocol
IEEE 802.1w for Rapid STP
IEEE 802.1s for Multiple Spanning Tree Protocol
IEEE 802.1Q for VLAN Tagging
IEEE 802.1p for Class of Service
IEEE 802.1x for Authentication
IEEE 802.3ad for Port Trunk with LACP |
• Software Features |
Management |
IPv4/IPv6, SNMP v1/v2c/v3, LLDP, Port Mirror, DDM, Fiber Check, RMON,
DHCP Server/Client, DHCP Option 66/67/82, BootP, TFTP, SMTP, RARP,
Telnet, Syslog, SNMP Inform, Flow Control, Back Pressure Flow Control |
Filter |
802.1Q VLAN, Port-Based VLAN, GVRP, IGMP v1/v2/v3, GMRP |
Redundancy Protocols |
STP, RSTP, MSTP, Turbo Ring v1/v2, Turbo Chain, Link Aggregation |
Security |
RADIUS, TACACS+, SSL, SSH, Broadcast Storm Protection, Port Lock |
Time Management |
SNTP, NTP Server/Client, IEEE 1588v2 PTP (software-based) |
Industrial Protocols |
EtherNet/IP, Modbus/TCP, PROFINET IO |
MIB |
MIB-II, Ethernet-Like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge MIB, RSTP
MIB, RMON MIB Group 1, 2, 3, 9 |
• Switch Properties |
Priority Queues |
4 |
Max. Number of Available VLANs |
64 |
VLAN ID Range |
VID 1 to 4094 |
IGMP Groups |
256 |
MAC Table Size |
16 K |
Packet Buffer Size |
1 Mbit |
• Interface |
RJ45 Ports |
10/100BaseT(X) or 10/100/1000BaseT(X) auto negotiation speed |
Fiber Ports |
100BaseFX (SC/ST connector) and 100/1000BaseSFP slot |
Console Port |
USB-serial console (Type B connector) |
Storage Port |
USB storage port (Type A connector) |
LED Indicators |
PWR1, PWR2, STATE, FAULT, 10/100M (TP port), 100M (fiber port),
100/1000M (Gigabit port), MSTR/HEAD, CPLR/TAIL |
Alarm Contact |
1 relay output with current carrying capacity of 1 A @ 24 VDC |
Digital Inputs |
1 input with the same ground, but electrically isolated from the
electronics.
• +13 to +30 V for state ¡§1¡¨
• -30 to +3 V for state ¡§0¡¨
• Max. input current: 8 mA |
Button |
Reset button |
• Optical Fiber |
|
• Power Requirements |
Input Voltage |
12/24/48/-48 VDC, redundant dual inputs |
Input Current |
EDS-518E-4GTXSFP: 0.75 A @ 24 V
EDS-518E-MM-ST/SC-4GTXSFP: 0.61 A @ 24 V
EDS-518E-SS-SC-4GTXSFP: 0.61 A @ 24 V |
Overload Current Protection |
Present |
Connection |
2 removable 4-contact terminal blocks |
Reverse Polarity Protection |
Present |
• Physical Characteristics |
Housing |
Metal |
IP Rating |
IP30 protection |
Dimensions |
94 x 135 x 137 mm (3.7 x 5.31 x 5.39 in) |
Weight |
1,518 g (3.35 lb) |
Installation |
DIN-rail mounting, wall mounting (with optional kit) |
• Environmental Limits |
Operating Temperature |
Standard Models: -10 to 60¢XC (14 to 140¢XF)
Wide Temp. Models: -40 to 75¢XC (-40 to 167¢XF) |
Storage Temperature |
-40 to 85¢XC (-40 to 185¢XF) |
Ambient Relative Humidity |
5 to 95% (non-condensing) |
• Standards and Certifications |
Safety |
UL 508 |
Hazardous Location |
UL/cUL Class 1 Division 2 Groups A/B/C/D,ATEX Zone 2 Ex nA nC IIC |
EMC |
EN 61000-6-2/6-4 |
EMI |
CISPR 22, FCC Part 15B Class A |
EMS |
IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV
IEC 61000-4-6 CS: Signal: 10 V
IEC 61000-4-8 |
Electrical Substations |
IEC 61850-3, IEEE 1613 |
Traffic Control |
NEMA TS2 |
Rail Traffic |
EN 50121-4 |
Shock |
IEC 60068-2-27 |
Freefall |
IEC 60068-2-32 |
Vibration |
IEC 60068-2-6
Note: Please check Moxa¡¦s website for the
most up-to-date certification status. |
• MTBF (mean time between
failures) |
Time |
723,953 hrs |
Standard |
Telcordia (Bellcore), GB |
• Warranty |
Warranty Period |
5 years |
Details |
See www.moxa.com/warranty |