­º­¶> ºô¸ô³]³Æ/ÀW¼eºÞ²z

>>ÂsÄý©Ò¦³HPºô¸ô³]³Æ/ÀW¼eºÞ²z

HP
HP ProCurve Switch 2626-PWR, (PoE) 24-port 10/100

«¬¸¹¡GJ8164A


HPJ8164A


°Ñ¦Ò°â»ù¡G½Ð¥ß§Y¨Ó¹q ¤O±ô¸ê°T
( »ù®æ¯}Ãa¦æ±¡¡I¨Ó¹q¬¢¸ß)



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºHP - J8164A - ºô¸ô³]³Æ/ÀW¼eºÞ²z
³Ì¦nªºHP - HP ProCurve Switch 2626-PWR, (PoE) 24-port 10/100±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´Úºô¸ô³]³Æ/ÀW¼eºÞ²z Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  
 ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I

¤@¯ë¥«»ù¡GNT$115932
°Ñ¦Ò°â»ù§C©ó¡GNT$88108
(½Ð¨Ó¹q¥Ñ·~°Èªì¨B³ø»ù ¹q¸Ü02-8969-0901#268)


·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù
¦Û°Ê¦C¦L³ø»ù³æ(¤´¥i¨Ó¹q¸ß°Ý§é¦©´T«×)


ÂsÄý³W®æ¬Ûªñ¤§HP²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>






¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§HP­ì¼t°t¥ó


¡@

¡@

¡@


HP
HP ProCurve Switch 2626-PWR, (PoE) 24-port 10/100 - ServerBank¸ê°T±ÄÁʺô
J8164A
ºô¸ô³]³Æ/ÀW¼eºÞ²z


¡@
²£«~³W®æ
HP part number ProCurve Switch 2650
(J4899B)
ProCurve Switch 2626
(J4900B)
ProCurve Switch 2626-PWR
(J8164A)
Ports 48 RJ-45 10/100 ports
(IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-T)

¡@

1 RS-232C DB-9 console port

¡@

2 Dual Personality Ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers)

¡@

24 RJ-45 10/100 ports
(IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-T)

¡@

1 RS-232C DB-9 console port

¡@

2 Dual Personality Ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers)

¡@

24 RJ-45 10/100 ports
(IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-T)

¡@

1 RS-232C DB-9 console port

¡@

2 Dual Personality Ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers)

¡@

Physical characteristics ¡@ ¡@ ¡@
Dimensions: 12.8 x 17.32 x 1.75 in.
(32.51 x 43.99 x 4.45 cm)
1U height
12.8 x 17.32 x 1.73 in.
(32.51 x 43.99 x 4.39 cm)
1U height
18.03 x 17.42 x 1.75 in.
(45.8 x 44.25 x 4.45 cm)
1U height
Weight: 9.78 lb (4.44 kg)
fully loaded
9.15 lb (4.15 kg)
fully loaded
15.01 lb (6.81 kg)
fully loaded
Memory and processor ¡@ ¡@ ¡@
Processor type and speed: Motorola PowerPC MPC8245, 266 MHz Motorola PowerPC MPC8245, 266 MHz Motorola PowerPC MPC8245, 266 MHz
Flash capacity: 8 MB 8 MB 8 MB
SDRAM: 32 MB 32 MB 32 MB
Performance ¡@ ¡@ ¡@
Latency: < 13.3 µs (LIFO) < 13.3 µs (LIFO) < 12 µs (LIFO)
Throughput: up to 10.1 million pps up to 6.6 million pps up to 6.6 million pps
Routing/switching capacity: 13.6 Gbps 9.6 Gbps 9.6 Gbps
Routing table size: 8000 entries 8000 entries 8000 entries
Environment ¡@ ¡@ ¡@
Operating temperature: 32 ¢XF to 131 ¢XF (0 ¢XC to 55 ¢XC) 32 ¢XF to 122 ¢XF (0 ¢XC to 50 ¢XC) 32 ¢XF to 122 ¢XF (0 ¢XC to 50 ¢XC)
Operating relative humidity: 15 % to 95 % at 104 ¢XF (40 ¢XC), noncondensing 15 % to 95 % at 104 ¢XF (40 ¢XC), noncondensing 15 % to 95 % at 104 ¢XF (40 ¢XC), noncondensing
Non-operating/storage temperature: -40 ¢XF to 158 ¢XF (-40 ¢XC to 70 ¢XC) -40 ¢XF to 158 ¢XF (-40 ¢XC to 70 ¢XC) -40 ¢XF to 158 ¢XF (-40 ¢XC to 70 ¢XC)
Non-operating/storage relative humidty: 15 % to 95 % at 149 ¢XF (65 ¢XC), noncondensing 15 % to 95 % at 149 ¢XF (65 ¢XC), noncondensing 15 % to 95 % at 149 ¢XF (65 ¢XC), noncondensing
Altitude: up to 15091 ft (4.6 km) up to 15091 ft (4.6 km) up to 15091 ft (4.6 km)
Acoustic: DIN 45635T.19 per ISO 7779 50 dB DIN 45635T.19 per ISO 7779 50 dB DIN 45635T.19 per ISO 7779 53 dB
Electrical characteristics ¡@ ¡@ ¡@
Maximum heat dissipation: 341 BTU/hr ( 359.76 kJ/hr ) 341 BTU/hr ( 359.76 kJ/hr ) 2288 BTU/hr ( 2413.84 kJ/hr )
Voltage: 100-120 VAC/200-240 VAC 100-120 VAC/200-240 VAC 100-120 VAC/200-240 VAC
Current: 1.5 A 1.5 A 6.4 A
Power: 100 W 100 W 631 W
Frequency: 50/60 Hz 50/60 Hz 50/60 Hz
Mounting ¡@ ¡@ ¡@
¡@ Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
Safety ¡@ ¡@ ¡@
¡@ CSA 22.2 No. 950; cUL (CSA 950); EN 60950/IEC 60950; NOM-019-SCFI-1994; UL 1950 3rd edition; UL 60950 CSA 22.2 No. 950; cUL (CSA 950); EN 60950/IEC 60950; NOM-019-SCFI-1994; UL 1950 3rd edition; UL 60950 CSA 22.2 No. 950; cUL (CSA 950); EN 60950/IEC 60950; NOM-019-SCFI-1994; UL 1950 3rd edition; UL 60950

» Return to top 

 

HP part number ProCurve Switch 2650-PWR
(J8165A)
ProCurve Switch 2600-8-PWR with Gigabit Uplink
(J8762A)
Ports 48 RJ-45 10/100 ports
(IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-T)

¡@

1 RS-232C DB-9 console port

¡@

2 Dual Personality Ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers)

¡@

8 RJ-45 10/100 ports
(IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-T)

¡@

Supports a maximum of 8 10/100 ports.

¡@

1 RS-232C DB-9 console port

¡@

1 Dual Personality Ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers)

¡@

Physical characteristics ¡@ ¡@
Dimensions: 18.03 x 17.42 x 1.75 in.
(45.8 x 44.25 x 4.45 cm)
1U height
8.86 x 17.44 x 1.73 in.
(22.5 x 44.3 x 4.39 cm)
1U height
Weight: 16.31 lb (7.4 kg)
fully loaded
7.5 lb (3.4 kg)
Memory and processor ¡@ ¡@
Processor type and speed: Motorola PowerPC MPC8245, 266 MHz Motorola PowerPC MPC8245, 266 MHz
Flash capacity: 8 MB 8 MB
SDRAM: 32 MB 32 MB
Performance ¡@ ¡@
Latency: < 12 µs (LIFO) < 12 µs (LIFO)
Throughput: 10.1 million pps up to 6.6 million pps
Routing/switching capacity: 13.6 Gbps 9.6 Gbps
Routing table size: 8000 entries 8000 entries
Environment ¡@ ¡@
Operating temperature: 32 ¢XF to 122 ¢XF (0 ¢XC to 50 ¢XC) 32 ¢XF to 122 ¢XF (0 ¢XC to 50 ¢XC)
Operating relative humidity: 15 % to 95 % at 104 ¢XF (40 ¢XC), noncondensing 15 % to 95 % at 104 ¢XF (40 ¢XC), noncondensing
Non-operating/storage temperature: -40 ¢XF to 158 ¢XF (-40 ¢XC to 70 ¢XC) -40 ¢XF to 158 ¢XF (-40 ¢XC to 70 ¢XC)
Non-operating/storage relative humidty: 15 % to 95 % at 149 ¢XF (65 ¢XC), noncondensing 15 % to 95 % at 149 ¢XF (65 ¢XC), noncondensing
Altitude: up to 15091 ft (4.6 km) up to 15091 ft (4.6 km)
Acoustic: DIN 45635T.19 per ISO 7779 53 dB DIN 45635T.19 per ISO 7779 57 dB
Electrical characteristics ¡@ ¡@
Maximum heat dissipation: 2288 BTU/hr ( 2413.84 kJ/hr ) 649 BTU/hr ( 684.7 kJ/hr ); inlcuding the switch and attached PoE devices; switch only: 228 BTU/hr
Voltage: 100-120 VAC/200-240 VAC 100-120 VAC/200-240 VAC
Current: 6.4 A 3.3 A /1.7 A
Power: 631 W 190 W
Frequency: 50/60 Hz 50/60 Hz
Mounting ¡@ ¡@
¡@ Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
Safety ¡@ ¡@
¡@ CSA 22.2 No. 950; cUL (CSA 950); EN 60950/IEC 60950; NOM-019-SCFI-1994; UL 1950 3rd edition; UL 60950 CSA 22.2 No. 950; cUL (CSA 950); EN 60950/IEC 60950; NOM-019-SCFI-1994; UL 1950 3rd edition; UL 60950

» Return to top 

 

src=http://welcome.hp-ww.com/img/s.gif

Standard specifications across all models

src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif
¡@
src=http://welcome.hp-ww.com/img/s.gif

Emissions

src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif
FCC Class A; EN55022/CISPR-22 Class A; VCCI Class A
src=http://welcome.hp-ww.com/img/s.gif
¡@
src=http://welcome.hp-ww.com/img/s.gif

Immunity

src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif
Generic: EN55024, CISPR 24
EN: EN55024, CISPR 24
ESD: IEC 61000-4-2; 4 kV CD, 8 kV AD
Radiated: IEC 61000-4-3; 3V/m
EFT/Burst: IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)
Surge: IEC 61000-4-5; 1 kV/2 kV AC
Conducted: IEC 61000-4-6; 3V
Power frequency magnetic field: IEC 61000-4-8; 1A/m, 50 or 60 Hz
Voltage dips and interruptions: IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25 periods
Harmonics: EN61000-3-2, IEC61000-3-2
Flicker: EN61000-3-3, IEC61000-3-3
src=http://welcome.hp-ww.com/img/s.gif
¡@
src=http://welcome.hp-ww.com/img/s.gif

Management

src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif
ProCurve Manager Plus; ProCurve Manager (included); command-line interface; Web browser; configuration menu; out-of-band management (serial RS-232C)
src=http://welcome.hp-ww.com/img/s.gif
¡@
src=http://welcome.hp-ww.com/img/s.gif

Standards and Protocols

src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif
RFC 783 TFTP
RFC 1542 BootP
RFC 768 UDP
RFC 793 TCP
RFC 2030 SNTP
DHCP Relay
RFC 2236 IGMP v1/v2/v3
IEEE 802.1w Rapid Convergence Spanning Tree
IEEE 802.1AB Link Layer Discovery Protocol
RFC 1492 TACACS+
Secure Sockets Layer (SSL)
802.3af Power over Ethernet
IEEE 802.1p Priority
HTML and telnet management
RFC 1213 MIB II
RFC 2737 Entity MIB
RFC 2665 Ethernet MIB
RFC 3164 Syslog
RFC 2668 802.3 MAU MIB
RFC 2674 802.1p and IEEE 802.1Q Bridge MIB
     
RFC 951 BootP
RFC 854 Telnet
RFC 792 ICMP
RFC 826 ARP
IEEE 802.3x Flow Control
RFC 3046 DHCP Relay Agent Information Option 82
IEEE 802.1D Spanning Tree
IEEE 802.3ad Link Aggregation Control Protocol
ANSI/TIA-1057 LLDP Media Endpoint Discovery (MED)
SSHv1/SSHv2 Secure Shell
IEEE 802.1X Network Login
IEEE 802.1Q GVRP
SNMPv1/v2c/v3
RFC 1493 Bridge MIB
RFC 2096 IP Forwarding Table MIB
RFC 2863 Evolution of Interface
RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events)
RFC 2021 RMON probe configuration (RMON v2)
RFC 2613 SMON
RFC 2618 RADIUS Client MIB

¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºHP - J8164A - ºô¸ô³]³Æ/ÀW¼eºÞ²z ,³Ì¦nªºHP - HP ProCurve Switch 2626-PWR, (PoE) 24-port 10/100±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú

¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C¡@

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B

 

 


¡@
         ServerBank ¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m@
         ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó
         ¹q¸Ü:
(02)8969-0901
          service@serverbank.com.tw
          www.ServerBank.com.tw
ServerBank¤O±ô­º­¶

¥þ³¡¤ÀÃþ | ¦Cªí | «~µP | ¶i¶¥·j´M | §Þ³N¤ä´©
¡@
¡@
¹q¸Ü(02)8969-0901
¡@
 ServerBank¼ö½æ¾÷ºØ
 ÀW¼e­t¸ü¥­¿Å
 2 WAN
 3 WAN
 4 WAN
 8 WAN¤Î¥H¤W
 ¾÷½c«¬¥æ´«¾¹
 ¥æ´«¾¹¼Ò²Õ
 µL½u¸ô¥Ñ¾¹
 ¤u·~¯ÅPOE¥æ´«¾¹
 ¤u·~¯Å¥æ´«¾¹
 ¤u·~¯Å¤á¥~«¬L2
 µL½u°T¸¹ÂX¥R¾¹
 ¤u·~¯ÅºôºÞ¥æ´«¾¹L2
 ¥ø·~¥æ´«¾¹
 ºÞ²z¾÷«¬
 ¤A¤Óºô¸ô¹q·½¨ÑÀ³¾¹
 ºô¸ô¥æ´«¾¹
 ¤u·~¯Å«DºôºÞ¥æ´«¾¹
 4G LTE¹h¹D¾¹
 L2 Switch
 µL½uºô¸ô±±¨î¾¹
 µL½u¼öÂI»{ÃÒ¹h¹D¾¹
 ±µ¤J¼h¥æ´«¾¹
 Wi-Fi AP
 ºôºÞ¥æ´«¾¹
 ÀW¼eºÞ²zQoS
 ¤@¯ë®à¤W«¬¥æ´«¾¹L2
 ºôºÞ¥æ´«¾¹L2
 ¤@¯ë¥æ´«¾¹L2
 L3 Switch
 L4 Switch
 PoE Switch
 ¼eÀWIP¤À¨É¾¹
 ¹q«H¯Å¸ô¥Ñ¾¹Router
 ¥ø·~¥Î¸ô¥Ñ¾¹Router
 ¦C¦L¦øªA¾¹
 §ë¼v¾÷¦øªA¾¹
 ºô¸ô¥d
 µL½uºô¸ôWLAN
 ¶°½u¾¹Hub
 µL½u°ò¦a¥x
«P¾P¬¡°Ê



¡@


ServerBank ¤O±ô¸ê°TServerBank¸ê°T±ÄÁʺô > ºô¸ô³]³Æ/ÀW¼eºÞ²z


HPJ8164A

HP ProCurve Switch 2626-PWR, (PoE) 24-port 10/100


¼tµP¡GHP      >>ÂsÄýHP¥þ³¡²£«~
«¬¸¹¡GJ8164A



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºHP - J8164A - ºô¸ô³]³Æ/ÀW¼eºÞ²z ,³Ì¦nªºHP - HP ProCurve Switch 2626-PWR, (PoE) 24-port 10/100±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´Úºô¸ô³]³Æ/ÀW¼eºÞ²z Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  

 

¤@¯ë¥«»ù¡GNT$115932
°Ñ¦Ò°â»ù§C©ó¡GNT$88108
(½Ð¨Ó¹q¥Ñ·~°Èªì¨B³ø»ù ¹q¸Ü02-8969-0901#268)


·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù


ÂsÄý³W®æ¬Ûªñ¤§HP²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>
¦Û°Ê¦C¦L³ø»ù³æ(½Ð¨Ó¹q¸ß°Ý§é¦©­°´T)






ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I
¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§HP­ì¼t°t¥ó


¡@

¡@

¡@


HP
HP ProCurve Switch 2626-PWR, (PoE) 24-port 10/100 - ServerBank¸ê°T±ÄÁʺô
J8164A
ºô¸ô³]³Æ/ÀW¼eºÞ²z


¡@
²£«~³W®æ
HP part number ProCurve Switch 2650
(J4899B)
ProCurve Switch 2626
(J4900B)
ProCurve Switch 2626-PWR
(J8164A)
Ports 48 RJ-45 10/100 ports
(IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-T)

¡@

1 RS-232C DB-9 console port

¡@

2 Dual Personality Ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers)

¡@

24 RJ-45 10/100 ports
(IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-T)

¡@

1 RS-232C DB-9 console port

¡@

2 Dual Personality Ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers)

¡@

24 RJ-45 10/100 ports
(IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-T)

¡@

1 RS-232C DB-9 console port

¡@

2 Dual Personality Ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers)

¡@

Physical characteristics ¡@ ¡@ ¡@
Dimensions: 12.8 x 17.32 x 1.75 in.
(32.51 x 43.99 x 4.45 cm)
1U height
12.8 x 17.32 x 1.73 in.
(32.51 x 43.99 x 4.39 cm)
1U height
18.03 x 17.42 x 1.75 in.
(45.8 x 44.25 x 4.45 cm)
1U height
Weight: 9.78 lb (4.44 kg)
fully loaded
9.15 lb (4.15 kg)
fully loaded
15.01 lb (6.81 kg)
fully loaded
Memory and processor ¡@ ¡@ ¡@
Processor type and speed: Motorola PowerPC MPC8245, 266 MHz Motorola PowerPC MPC8245, 266 MHz Motorola PowerPC MPC8245, 266 MHz
Flash capacity: 8 MB 8 MB 8 MB
SDRAM: 32 MB 32 MB 32 MB
Performance ¡@ ¡@ ¡@
Latency: < 13.3 µs (LIFO) < 13.3 µs (LIFO) < 12 µs (LIFO)
Throughput: up to 10.1 million pps up to 6.6 million pps up to 6.6 million pps
Routing/switching capacity: 13.6 Gbps 9.6 Gbps 9.6 Gbps
Routing table size: 8000 entries 8000 entries 8000 entries
Environment ¡@ ¡@ ¡@
Operating temperature: 32 ¢XF to 131 ¢XF (0 ¢XC to 55 ¢XC) 32 ¢XF to 122 ¢XF (0 ¢XC to 50 ¢XC) 32 ¢XF to 122 ¢XF (0 ¢XC to 50 ¢XC)
Operating relative humidity: 15 % to 95 % at 104 ¢XF (40 ¢XC), noncondensing 15 % to 95 % at 104 ¢XF (40 ¢XC), noncondensing 15 % to 95 % at 104 ¢XF (40 ¢XC), noncondensing
Non-operating/storage temperature: -40 ¢XF to 158 ¢XF (-40 ¢XC to 70 ¢XC) -40 ¢XF to 158 ¢XF (-40 ¢XC to 70 ¢XC) -40 ¢XF to 158 ¢XF (-40 ¢XC to 70 ¢XC)
Non-operating/storage relative humidty: 15 % to 95 % at 149 ¢XF (65 ¢XC), noncondensing 15 % to 95 % at 149 ¢XF (65 ¢XC), noncondensing 15 % to 95 % at 149 ¢XF (65 ¢XC), noncondensing
Altitude: up to 15091 ft (4.6 km) up to 15091 ft (4.6 km) up to 15091 ft (4.6 km)
Acoustic: DIN 45635T.19 per ISO 7779 50 dB DIN 45635T.19 per ISO 7779 50 dB DIN 45635T.19 per ISO 7779 53 dB
Electrical characteristics ¡@ ¡@ ¡@
Maximum heat dissipation: 341 BTU/hr ( 359.76 kJ/hr ) 341 BTU/hr ( 359.76 kJ/hr ) 2288 BTU/hr ( 2413.84 kJ/hr )
Voltage: 100-120 VAC/200-240 VAC 100-120 VAC/200-240 VAC 100-120 VAC/200-240 VAC
Current: 1.5 A 1.5 A 6.4 A
Power: 100 W 100 W 631 W
Frequency: 50/60 Hz 50/60 Hz 50/60 Hz
Mounting ¡@ ¡@ ¡@
¡@ Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
Safety ¡@ ¡@ ¡@
¡@ CSA 22.2 No. 950; cUL (CSA 950); EN 60950/IEC 60950; NOM-019-SCFI-1994; UL 1950 3rd edition; UL 60950 CSA 22.2 No. 950; cUL (CSA 950); EN 60950/IEC 60950; NOM-019-SCFI-1994; UL 1950 3rd edition; UL 60950 CSA 22.2 No. 950; cUL (CSA 950); EN 60950/IEC 60950; NOM-019-SCFI-1994; UL 1950 3rd edition; UL 60950

» Return to top 

 

HP part number ProCurve Switch 2650-PWR
(J8165A)
ProCurve Switch 2600-8-PWR with Gigabit Uplink
(J8762A)
Ports 48 RJ-45 10/100 ports
(IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-T)

¡@

1 RS-232C DB-9 console port

¡@

2 Dual Personality Ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers)

¡@

8 RJ-45 10/100 ports
(IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-T)

¡@

Supports a maximum of 8 10/100 ports.

¡@

1 RS-232C DB-9 console port

¡@

1 Dual Personality Ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers)

¡@

Physical characteristics ¡@ ¡@
Dimensions: 18.03 x 17.42 x 1.75 in.
(45.8 x 44.25 x 4.45 cm)
1U height
8.86 x 17.44 x 1.73 in.
(22.5 x 44.3 x 4.39 cm)
1U height
Weight: 16.31 lb (7.4 kg)
fully loaded
7.5 lb (3.4 kg)
Memory and processor ¡@ ¡@
Processor type and speed: Motorola PowerPC MPC8245, 266 MHz Motorola PowerPC MPC8245, 266 MHz
Flash capacity: 8 MB 8 MB
SDRAM: 32 MB 32 MB
Performance ¡@ ¡@
Latency: < 12 µs (LIFO) < 12 µs (LIFO)
Throughput: 10.1 million pps up to 6.6 million pps
Routing/switching capacity: 13.6 Gbps 9.6 Gbps
Routing table size: 8000 entries 8000 entries
Environment ¡@ ¡@
Operating temperature: 32 ¢XF to 122 ¢XF (0 ¢XC to 50 ¢XC) 32 ¢XF to 122 ¢XF (0 ¢XC to 50 ¢XC)
Operating relative humidity: 15 % to 95 % at 104 ¢XF (40 ¢XC), noncondensing 15 % to 95 % at 104 ¢XF (40 ¢XC), noncondensing
Non-operating/storage temperature: -40 ¢XF to 158 ¢XF (-40 ¢XC to 70 ¢XC) -40 ¢XF to 158 ¢XF (-40 ¢XC to 70 ¢XC)
Non-operating/storage relative humidty: 15 % to 95 % at 149 ¢XF (65 ¢XC), noncondensing 15 % to 95 % at 149 ¢XF (65 ¢XC), noncondensing
Altitude: up to 15091 ft (4.6 km) up to 15091 ft (4.6 km)
Acoustic: DIN 45635T.19 per ISO 7779 53 dB DIN 45635T.19 per ISO 7779 57 dB
Electrical characteristics ¡@ ¡@
Maximum heat dissipation: 2288 BTU/hr ( 2413.84 kJ/hr ) 649 BTU/hr ( 684.7 kJ/hr ); inlcuding the switch and attached PoE devices; switch only: 228 BTU/hr
Voltage: 100-120 VAC/200-240 VAC 100-120 VAC/200-240 VAC
Current: 6.4 A 3.3 A /1.7 A
Power: 631 W 190 W
Frequency: 50/60 Hz 50/60 Hz
Mounting ¡@ ¡@
¡@ Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
Safety ¡@ ¡@
¡@ CSA 22.2 No. 950; cUL (CSA 950); EN 60950/IEC 60950; NOM-019-SCFI-1994; UL 1950 3rd edition; UL 60950 CSA 22.2 No. 950; cUL (CSA 950); EN 60950/IEC 60950; NOM-019-SCFI-1994; UL 1950 3rd edition; UL 60950

» Return to top 

 

src=http://welcome.hp-ww.com/img/s.gif

Standard specifications across all models

src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif
¡@
src=http://welcome.hp-ww.com/img/s.gif

Emissions

src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif
FCC Class A; EN55022/CISPR-22 Class A; VCCI Class A
src=http://welcome.hp-ww.com/img/s.gif
¡@
src=http://welcome.hp-ww.com/img/s.gif

Immunity

src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif
Generic: EN55024, CISPR 24
EN: EN55024, CISPR 24
ESD: IEC 61000-4-2; 4 kV CD, 8 kV AD
Radiated: IEC 61000-4-3; 3V/m
EFT/Burst: IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)
Surge: IEC 61000-4-5; 1 kV/2 kV AC
Conducted: IEC 61000-4-6; 3V
Power frequency magnetic field: IEC 61000-4-8; 1A/m, 50 or 60 Hz
Voltage dips and interruptions: IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25 periods
Harmonics: EN61000-3-2, IEC61000-3-2
Flicker: EN61000-3-3, IEC61000-3-3
src=http://welcome.hp-ww.com/img/s.gif
¡@
src=http://welcome.hp-ww.com/img/s.gif

Management

src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif
ProCurve Manager Plus; ProCurve Manager (included); command-line interface; Web browser; configuration menu; out-of-band management (serial RS-232C)
src=http://welcome.hp-ww.com/img/s.gif
¡@
src=http://welcome.hp-ww.com/img/s.gif

Standards and Protocols

src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif
RFC 783 TFTP
RFC 1542 BootP
RFC 768 UDP
RFC 793 TCP
RFC 2030 SNTP
DHCP Relay
RFC 2236 IGMP v1/v2/v3
IEEE 802.1w Rapid Convergence Spanning Tree
IEEE 802.1AB Link Layer Discovery Protocol
RFC 1492 TACACS+
Secure Sockets Layer (SSL)
802.3af Power over Ethernet
IEEE 802.1p Priority
HTML and telnet management
RFC 1213 MIB II
RFC 2737 Entity MIB
RFC 2665 Ethernet MIB
RFC 3164 Syslog
RFC 2668 802.3 MAU MIB
RFC 2674 802.1p and IEEE 802.1Q Bridge MIB
     
RFC 951 BootP
RFC 854 Telnet
RFC 792 ICMP
RFC 826 ARP
IEEE 802.3x Flow Control
RFC 3046 DHCP Relay Agent Information Option 82
IEEE 802.1D Spanning Tree
IEEE 802.3ad Link Aggregation Control Protocol
ANSI/TIA-1057 LLDP Media Endpoint Discovery (MED)
SSHv1/SSHv2 Secure Shell
IEEE 802.1X Network Login
IEEE 802.1Q GVRP
SNMPv1/v2c/v3
RFC 1493 Bridge MIB
RFC 2096 IP Forwarding Table MIB
RFC 2863 Evolution of Interface
RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events)
RFC 2021 RMON probe configuration (RMON v2)
RFC 2613 SMON
RFC 2618 RADIUS Client MIB

¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank ¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºHP - J8164A - ºô¸ô³]³Æ/ÀW¼eºÞ²z ,³Ì¦nªºHP - HP ProCurve Switch 2626-PWR, (PoE) 24-port 10/100±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú
¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B


¡@
¡@

ServerBank¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m service@serverbank.com.tw
¹q¸Ü(02)8969-0901 ¶Ç¯u(02)2253-9016 ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó

¡@
¡@