­º­¶> ºô¸ô³]³Æ/ÀW¼eºÞ²z

>>ÂsÄý©Ò¦³HPºô¸ô³]³Æ/ÀW¼eºÞ²z

HP
HP ProCurve Switch 2810-48G, 44-port 10/100/1000 + 4 combo 10/100/1000

«¬¸¹¡GJ9022A


HPJ9022A


°Ñ¦Ò°â»ù¡G½Ð¥ß§Y¨Ó¹q ¤O±ô¸ê°T
( »ù®æ¯}Ãa¦æ±¡¡I¨Ó¹q¬¢¸ß)



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºHP - J9022A - ºô¸ô³]³Æ/ÀW¼eºÞ²z
³Ì¦nªºHP - HP ProCurve Switch 2810-48G, 44-port 10/100/1000 + 4 combo 10/100/1000±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´Úºô¸ô³]³Æ/ÀW¼eºÞ²z Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  
 ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I

¤@¯ë¥«»ù¡GNT$179199 °â»ù§C©ó¡GNT$159288
(½Ð¨Ó¹q¥Ñ·~°Èªì¨B³ø»ù ¹q¸Ü02-8969-0901#268)


·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù
¦Û°Ê¦C¦L³ø»ù³æ(¤´¥i¨Ó¹q¸ß°Ý§é¦©´T«×)


ÂsÄý³W®æ¬Ûªñ¤§HP²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>






¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§HP­ì¼t°t¥ó


¡@

¡@

¡@


HP
HP ProCurve Switch 2810-48G, 44-port 10/100/1000 + 4 combo 10/100/1000 - ServerBank¸ê°T±ÄÁʺô
J9022A
ºô¸ô³]³Æ/ÀW¼eºÞ²z


¡@
²£«~³W®æ
HP part number ProCurve Switch 2810-24G
(J9021A)
ProCurve Switch 2810-48G
(J9022A)
Ports 20 RJ-45 10/100/1000 ports
(IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-T, IEEE 802.3ab Type 1000Base-T)

¡@

1 RJ-45 serial console port

¡@

4 Dual Personality Ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers)

¡@

44 RJ-45 10/100/1000 ports
(IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-T, IEEE 802.3ab Type 1000Base-T)

¡@

1 RJ-45 serial console port

¡@

4 Dual Personality Ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers)

¡@

Physical characteristics ¡@ ¡@
Dimensions: 12.7 x 17.4 x 1.7 in.
(32.26 x 44.2 x 4.32 cm)
1U height
12.7 x 17.4 x 1.7 in.
(32.26 x 44.2 x 4.32 cm)
1U height
Weight: 7.21 lb (3.27 kg) 8.6 lb (3.9 kg)
Memory and processor ¡@ ¡@
Processor type and speed: MIPS BCM5836, 264 MHz MIPS BCM5836, 264 MHz
Packet buffer size: 0.75 MB 1.5 MB
Flash capacity: 16 MB 16 MB
SDRAM: 64 MB 64 MB
Performance ¡@ ¡@
Latency: < 5.6 µs (FIFO 64-byte packets) < 5.4 µs (FIFO 64-byte packets)
Throughput: up to 35.7 million pps up to 71.4 million pps
Switching capacity: 48 Gbps 96 Gbps
MAC address table size: 8000 entries 8000 entries
Environment ¡@ ¡@
Operating temperature: 32 ¢XF to 104 ¢XF (0 ¢XC to 40 ¢XC) 32 ¢XF to 113 ¢XF (0 ¢XC to 45 ¢XC)
Operating relative humidity: 15 % to 95 % at 104 ¢XF (40 ¢XC), noncondensing 15 % to 95 % at 104 ¢XF (40 ¢XC), noncondensing
Non-operating/storage temperature: -40 ¢XF to 158 ¢XF (-40 ¢XC to 70 ¢XC) -40 ¢XF to 158 ¢XF (-40 ¢XC to 70 ¢XC)
Non-operating/storage relative humidty: 15 % to 95 % at 149 ¢XF (65 ¢XC), noncondensing 15 % to 95 % at 149 ¢XF (65 ¢XC), noncondensing
Altitude: up to 10000 ft (3 km) up to 10000 ft (3 km)
Electrical characteristics ¡@ ¡@
Maximum heat dissipation: 164 BTU/hr 341 BTU/hr
Voltage: 100-127 VAC/200-240 VAC 100-127 VAC/200-240 VAC
Current: 1.25 A /0.75 A 2.0 A /1.0 A
Frequency: 50/60 Hz 50/60 Hz
Mounting ¡@ ¡@
¡@ Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
Safety ¡@ ¡@
¡@ cUL (CSA 22.2 No. 60950); EN 60950/IEC 60950; NOM-019-SCFI-1994; UL 60950 cUL (CSA 22.2 No. 60950); EN 60950/IEC 60950; NOM-019-SCFI-1994; UL 60950

» Return to top 

 

src=http://welcome.hp-ww.com/img/s.gif

Standard specifications across all models

src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif
¡@
src=http://welcome.hp-ww.com/img/s.gif

Emissions

src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif
FCC Class A; EN55022/CISPR-22 Class A; VCCI Class A; IEC/EN61000-3-2; IEC/EN61000-3-3
src=http://welcome.hp-ww.com/img/s.gif
¡@
src=http://welcome.hp-ww.com/img/s.gif

Immunity

src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif
EN: EN55024, CISPR 24
ESD: IEC 61000-4-2; 4 kV CD, 8kV AD
Radiated: IEC 61000-4-3; 3V/m
EFT/Burst: IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)
Surge: IEC 61000-4-5; 1 kV/2 kV AC
Conducted: IEC 61000-4-6; 3V
Power frequency magnetic field: IEC 61000-4-8; 1A/m, 50 or 60 Hz
Voltage dips and interruptions: IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25 periods
Harmonics: EN61000-3-2, IEC61000-3-2
Flicker: EN61000-3-3, IEC61000-3-3
src=http://welcome.hp-ww.com/img/s.gif
¡@
src=http://welcome.hp-ww.com/img/s.gif

Management

src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif
ProCurve Manager Plus; ProCurve Manager; command-line interface; Web browser; configuration menu; out-of-band management
src=http://welcome.hp-ww.com/img/s.gif
¡@
src=http://welcome.hp-ww.com/img/s.gif

Standards and Protocols

src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif
RFC 783 TFTP
RFC 1542 BootP
RFC 768 UDP
RFC 793 TCP
RFC 2030 Simple Network Time Protocol
RFC 3376 IGMPv1/v2/v3
IEEE 802.1w Rapid Convergence Spanning Tree
IEEE 802.3ad Link Aggregation Control Protocol
RFC 2138 RADIUS
SSHv2 Secure Shell
IEEE 802.1X Network Login
IEEE 802.1Q GVRP
SNMPv1/v2c/v3
RFC 1493 Bridge MIB
RFC 2096 IP Forwarding Table MIB
RFC 2863 Evolution of Interface
RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events)
RFC 2668 802.3 MAU MIB
RFC 2674 802.1p and IEEE 802.1Q Bridge MIB
RFC 2620 RADIUS Accounting MIB
     
RFC 951 BootP
RFC 854 Telnet
RFC 792 ICMP
RFC 826 ARP
IEEE 802.3x Flow Control
IEEE 802.1D Spanning Tree
IEEE 802.1s Multiple Spanning Trees
RFC 1492 TACACS+
RFC 2866 RADIUS accounting
Secure Sockets Layer (SSL)
IEEE 802.1Q VLANs
IEEE 802.1p Priority
HTML and telnet management
RFC 1213 MIB II
RFC 2737 Entity MIB
RFC 2665 Ethernet MIB
RFC 2021 RMON probe configuration (RMON v2)
RFC 2613 SMON
RFC 2618 RADIUS Client MIB
RFC 3176 sFlow
src=http://welcome.hp-ww.com/img/s.gif
¡@
src=http://welcome.hp-ww.com/img/s.gif

Notes

src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif
When using mini-GBICs with this product, mini-GBICs with revision "B" (product number ends with the letter "B", e.g. J4858B, J4859B) or later are required.
src=http://welcome.hp-ww.com/img/s.gif

¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºHP - J9022A - ºô¸ô³]³Æ/ÀW¼eºÞ²z ,³Ì¦nªºHP - HP ProCurve Switch 2810-48G, 44-port 10/100/1000 + 4 combo 10/100/1000±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú

¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C¡@

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B

 

 


¡@
         ServerBank ¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m@
         ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó
         ¹q¸Ü:
(02)8969-0901
          service@serverbank.com.tw
          www.ServerBank.com.tw
ServerBank¤O±ô­º­¶

¥þ³¡¤ÀÃþ | ¦Cªí | «~µP | ¶i¶¥·j´M | §Þ³N¤ä´©
¡@
¡@
¹q¸Ü(02)8969-0901
¡@
 ServerBank¼ö½æ¾÷ºØ
 ÀW¼e­t¸ü¥­¿Å
 2 WAN
 3 WAN
 4 WAN
 8 WAN¤Î¥H¤W
 ¾÷½c«¬¥æ´«¾¹
 ¥æ´«¾¹¼Ò²Õ
 µL½u¸ô¥Ñ¾¹
 ¤u·~¯ÅPOE¥æ´«¾¹
 ¤u·~¯Å¥æ´«¾¹
 ¤u·~¯Å¤á¥~«¬L2
 µL½u°T¸¹ÂX¥R¾¹
 ¤u·~¯ÅºôºÞ¥æ´«¾¹L2
 ¥ø·~¥æ´«¾¹
 ºÞ²z¾÷«¬
 ¤A¤Óºô¸ô¹q·½¨ÑÀ³¾¹
 ºô¸ô¥æ´«¾¹
 ¤u·~¯Å«DºôºÞ¥æ´«¾¹
 4G LTE¹h¹D¾¹
 L2 Switch
 µL½uºô¸ô±±¨î¾¹
 µL½u¼öÂI»{ÃÒ¹h¹D¾¹
 ±µ¤J¼h¥æ´«¾¹
 Wi-Fi AP
 ºôºÞ¥æ´«¾¹
 ÀW¼eºÞ²zQoS
 ¤@¯ë®à¤W«¬¥æ´«¾¹L2
 ºôºÞ¥æ´«¾¹L2
 ¤@¯ë¥æ´«¾¹L2
 L3 Switch
 L4 Switch
 PoE Switch
 ¼eÀWIP¤À¨É¾¹
 ¹q«H¯Å¸ô¥Ñ¾¹Router
 ¥ø·~¥Î¸ô¥Ñ¾¹Router
 ¦C¦L¦øªA¾¹
 §ë¼v¾÷¦øªA¾¹
 ºô¸ô¥d
 µL½uºô¸ôWLAN
 ¶°½u¾¹Hub
 µL½u°ò¦a¥x
«P¾P¬¡°Ê



¡@


ServerBank ¤O±ô¸ê°TServerBank¸ê°T±ÄÁʺô > ºô¸ô³]³Æ/ÀW¼eºÞ²z


HPJ9022A

HP ProCurve Switch 2810-48G, 44-port 10/100/1000 + 4 combo 10/100/1000


¼tµP¡GHP      >>ÂsÄýHP¥þ³¡²£«~
«¬¸¹¡GJ9022A



ServerBank¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºHP - J9022A - ºô¸ô³]³Æ/ÀW¼eºÞ²z ,³Ì¦nªºHP - HP ProCurve Switch 2810-48G, 44-port 10/100/1000 + 4 combo 10/100/1000±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
¶W¦h´Úºô¸ô³]³Æ/ÀW¼eºÞ²z Åwªï±z¨Ó¹q°Q½×±ÄÁʻݨD¡A²{¦b§ó¦³¦h­«Àu´f¤è®×³á
¥»¯¸°Ó«~§¡¸û¦P·~»PºôÁÊ«K©y,¥ø·~ªø´Á±ÄÁÊ ¶q¤j¥t¦³§é¦©³á!  

 

¤@¯ë¥«»ù¡GNT$179199 °â»ù§C©ó¡GNT$159288
(½Ð¨Ó¹q¥Ñ·~°Èªì¨B³ø»ù ¹q¸Ü02-8969-0901#268)


·|­û»ù>>¯Á¨ú¦¹°Ó«~³ø»ù


ÂsÄý³W®æ¬Ûªñ¤§HP²£«~>>
ÂsÄý³W®æ¬Ûªñ¤§¨ä¥L«~µP²£«~>>
¦Û°Ê¦C¦L³ø»ù³æ(½Ð¨Ó¹q¸ß°Ý§é¦©­°´T)






ServerBankÂX¤j©Û¶Ò·~°È¦P¤¯¡I
¥[ÁÊ ¼Ð·Ç°t³Æ¥H¥~¤§HP­ì¼t°t¥ó


¡@

¡@

¡@


HP
HP ProCurve Switch 2810-48G, 44-port 10/100/1000 + 4 combo 10/100/1000 - ServerBank¸ê°T±ÄÁʺô
J9022A
ºô¸ô³]³Æ/ÀW¼eºÞ²z


¡@
²£«~³W®æ
HP part number ProCurve Switch 2810-24G
(J9021A)
ProCurve Switch 2810-48G
(J9022A)
Ports 20 RJ-45 10/100/1000 ports
(IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-T, IEEE 802.3ab Type 1000Base-T)

¡@

1 RJ-45 serial console port

¡@

4 Dual Personality Ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers)

¡@

44 RJ-45 10/100/1000 ports
(IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-T, IEEE 802.3ab Type 1000Base-T)

¡@

1 RJ-45 serial console port

¡@

4 Dual Personality Ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers)

¡@

Physical characteristics ¡@ ¡@
Dimensions: 12.7 x 17.4 x 1.7 in.
(32.26 x 44.2 x 4.32 cm)
1U height
12.7 x 17.4 x 1.7 in.
(32.26 x 44.2 x 4.32 cm)
1U height
Weight: 7.21 lb (3.27 kg) 8.6 lb (3.9 kg)
Memory and processor ¡@ ¡@
Processor type and speed: MIPS BCM5836, 264 MHz MIPS BCM5836, 264 MHz
Packet buffer size: 0.75 MB 1.5 MB
Flash capacity: 16 MB 16 MB
SDRAM: 64 MB 64 MB
Performance ¡@ ¡@
Latency: < 5.6 µs (FIFO 64-byte packets) < 5.4 µs (FIFO 64-byte packets)
Throughput: up to 35.7 million pps up to 71.4 million pps
Switching capacity: 48 Gbps 96 Gbps
MAC address table size: 8000 entries 8000 entries
Environment ¡@ ¡@
Operating temperature: 32 ¢XF to 104 ¢XF (0 ¢XC to 40 ¢XC) 32 ¢XF to 113 ¢XF (0 ¢XC to 45 ¢XC)
Operating relative humidity: 15 % to 95 % at 104 ¢XF (40 ¢XC), noncondensing 15 % to 95 % at 104 ¢XF (40 ¢XC), noncondensing
Non-operating/storage temperature: -40 ¢XF to 158 ¢XF (-40 ¢XC to 70 ¢XC) -40 ¢XF to 158 ¢XF (-40 ¢XC to 70 ¢XC)
Non-operating/storage relative humidty: 15 % to 95 % at 149 ¢XF (65 ¢XC), noncondensing 15 % to 95 % at 149 ¢XF (65 ¢XC), noncondensing
Altitude: up to 10000 ft (3 km) up to 10000 ft (3 km)
Electrical characteristics ¡@ ¡@
Maximum heat dissipation: 164 BTU/hr 341 BTU/hr
Voltage: 100-127 VAC/200-240 VAC 100-127 VAC/200-240 VAC
Current: 1.25 A /0.75 A 2.0 A /1.0 A
Frequency: 50/60 Hz 50/60 Hz
Mounting ¡@ ¡@
¡@ Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
Safety ¡@ ¡@
¡@ cUL (CSA 22.2 No. 60950); EN 60950/IEC 60950; NOM-019-SCFI-1994; UL 60950 cUL (CSA 22.2 No. 60950); EN 60950/IEC 60950; NOM-019-SCFI-1994; UL 60950

» Return to top 

 

src=http://welcome.hp-ww.com/img/s.gif

Standard specifications across all models

src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif
¡@
src=http://welcome.hp-ww.com/img/s.gif

Emissions

src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif
FCC Class A; EN55022/CISPR-22 Class A; VCCI Class A; IEC/EN61000-3-2; IEC/EN61000-3-3
src=http://welcome.hp-ww.com/img/s.gif
¡@
src=http://welcome.hp-ww.com/img/s.gif

Immunity

src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif
EN: EN55024, CISPR 24
ESD: IEC 61000-4-2; 4 kV CD, 8kV AD
Radiated: IEC 61000-4-3; 3V/m
EFT/Burst: IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)
Surge: IEC 61000-4-5; 1 kV/2 kV AC
Conducted: IEC 61000-4-6; 3V
Power frequency magnetic field: IEC 61000-4-8; 1A/m, 50 or 60 Hz
Voltage dips and interruptions: IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25 periods
Harmonics: EN61000-3-2, IEC61000-3-2
Flicker: EN61000-3-3, IEC61000-3-3
src=http://welcome.hp-ww.com/img/s.gif
¡@
src=http://welcome.hp-ww.com/img/s.gif

Management

src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif
ProCurve Manager Plus; ProCurve Manager; command-line interface; Web browser; configuration menu; out-of-band management
src=http://welcome.hp-ww.com/img/s.gif
¡@
src=http://welcome.hp-ww.com/img/s.gif

Standards and Protocols

src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif
RFC 783 TFTP
RFC 1542 BootP
RFC 768 UDP
RFC 793 TCP
RFC 2030 Simple Network Time Protocol
RFC 3376 IGMPv1/v2/v3
IEEE 802.1w Rapid Convergence Spanning Tree
IEEE 802.3ad Link Aggregation Control Protocol
RFC 2138 RADIUS
SSHv2 Secure Shell
IEEE 802.1X Network Login
IEEE 802.1Q GVRP
SNMPv1/v2c/v3
RFC 1493 Bridge MIB
RFC 2096 IP Forwarding Table MIB
RFC 2863 Evolution of Interface
RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events)
RFC 2668 802.3 MAU MIB
RFC 2674 802.1p and IEEE 802.1Q Bridge MIB
RFC 2620 RADIUS Accounting MIB
     
RFC 951 BootP
RFC 854 Telnet
RFC 792 ICMP
RFC 826 ARP
IEEE 802.3x Flow Control
IEEE 802.1D Spanning Tree
IEEE 802.1s Multiple Spanning Trees
RFC 1492 TACACS+
RFC 2866 RADIUS accounting
Secure Sockets Layer (SSL)
IEEE 802.1Q VLANs
IEEE 802.1p Priority
HTML and telnet management
RFC 1213 MIB II
RFC 2737 Entity MIB
RFC 2665 Ethernet MIB
RFC 2021 RMON probe configuration (RMON v2)
RFC 2613 SMON
RFC 2618 RADIUS Client MIB
RFC 3176 sFlow
src=http://welcome.hp-ww.com/img/s.gif
¡@
src=http://welcome.hp-ww.com/img/s.gif

Notes

src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif
src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif src=http://welcome.hp-ww.com/img/s.gif
When using mini-GBICs with this product, mini-GBICs with revision "B" (product number ends with the letter "B", e.g. J4858B, J4859B) or later are required.
src=http://welcome.hp-ww.com/img/s.gif

¡D¥»¤å¥óªº¸ê°T­Y¦³­×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ù­Y¦³»~¡A¥H­ì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨ä­ì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C

º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á! ServerBank ¤O±ô¸ê°Tµ¹§A³Ì¶W­ÈÀu´fªºHP - J9022A - ºô¸ô³]³Æ/ÀW¼eºÞ²z ,³Ì¦nªºHP - HP ProCurve Switch 2810-48G, 44-port 10/100/1000 + 4 combo 10/100/1000±ÄÁÊ¿ï¾Ü´N¦b ServerBank!


¥æ©ö¤Î¹B°e«O©T»¡©ú
¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§Ú­Ì·|¬°±z¦V­ì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú­Ì³£¥i¼u©Ê°t¦X±zªº»Ý­n³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G

1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»­¶ÁʶR¸ß»ù§Ú­Ì·|¥ß§Y»P±zÁpô!
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw
¥I´Ú¤è¦¡¡G¦p«È¤á¬°­º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C
¶Ç¯u­q³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨­qÁʵ{§Ç¡A§Ú­Ì·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{­q³æ¡C
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 ­Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú­Ì¦¬¨ì±z­q³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C
°e³f¤è¦¡¡G(1) ­ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C
°e³f½d³ò¡G­­¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±z­t¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C
°â«áªA°È¡G­Y²£«~¥»¨­·å²«©Î¹B°e¹Lµ{¾É­P·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C
«O©T¬Fµ¦¡G ¹ê»Ú¥H­ì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C

¤O±ô¸ê°T ServerBank Inc. ²¤¶

¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G

»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶­Û¡B¥xÆWªFªÛ¡B¥xÆW­^­¸­â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B­¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B

¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B

ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B

¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L­·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B

Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥­¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B

­¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸­¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß­¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B

´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B­¸ºÐ¼s¼½¡B­·¼é°Û¤ù¡B®É³ø©P¥Z¡B

±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤­ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B

²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡B­ì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°

¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B

ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B

¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B

¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤­±]±¶¹B¡B¥xÆW´¼¼z¥d¡B

¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½­^¡B¿ßÀYÆN

©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B

­x¤è¡G ªÅ­x¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B


¡@
¡@

ServerBank¥Ñ¤O±ô¸ê°TªÑ¥÷¦³­­¤½¥q«Ø¸m service@serverbank.com.tw
¹q¸Ü(02)8969-0901 ¶Ç¯u(02)2253-9016 ·s¥_¥«ªO¾ô°Ï¤å¤Æ¸ô¤@¬q268¸¹3¼Ó

¡@
¡@