Standard Interfaces
|
Host interface
|
320MB SCSI LVD
|
|
Drives |
320MB SCSI 3.5 in.
low profile |
|
Supported drives
|
73GB 10K rpm; 73GB
15K rpm; 146GB 10K rpm; 146GB 15K
rpm; 300GB 10K rpm |
|
Maximum number of
host ports |
- 3x320MB SCSI host ports
(without expansion trays);
- 2x320MB SCSI host ports
(with 1 expansion tray);
- 1x320MB SCSI host port (with
2 expansion trays)
|
|
Maximum cable
lengh |
12 m |
Tray (12 HDDs) and RAID Array
(36 HDDs) Maximum Raw Storage
Capacities
|
73GB 10K rpm and
15K rpm HDDs |
876GB per 2U tray;
expandable to 2.6TB per RAID array
|
|
146GB 10K rpm and
15K rpm HDDs |
1.72TB per 2U
tray; expandable to 5.2TB per RAID
array
|
|
300GB 10K rpm HDDs
|
3.60TB per 2U
tray; expandable to 10.8TB per RAID
array
|
RAID Controller Card
|
RAID
configurations |
Per Tray: JBOD/Expansion
(no controller); single RAID
controller; dual (mirrored) RAID
controllers |
|
RAID levels |
0, 1, 1+0, 3, 5,
3+0, and 5+0 |
|
Max. LUNS |
Up to 128 per RAID
array |
|
Max. local and/or
global hot spares |
Up to 20 (RAID set
and disk quantity dependent) per
RAID array
|
|
Cache size (read
and write) |
512MB per
controller |
|
Cache battery
backup |
Up to 72 hours
|
|
Cache write policy
(user configurable) |
Write
Back¡Xdefault; Write Through¡Xdefault
for single controller or on
battery/controller frame |
|
Cache selectable
block sizes |
32K (random file
transfer); 128K (sequential file
transfer)
|
|
Included
Management software |
Sun StorEdge
Configuration Service; Sun StorEdge
Diagnostic Reporter software
Vibration 0.2 G, 5¡V500 Hz,
swept-sine 1.0 G, 5¡V500 Hz,
swept-sine |
|
Optional supported
software |
Sun StorEdge
Enterprise Storage Manager, Sun
StorEdge Traffic Manager, Sun
Cluster 3, VERITAS NetBackup and
VERITAS Volume Manager including
DMP, Sun Logical Volume Manager for
the Solaris 9 Operating System, Sun
Solstice DiskSuite for the Solaris 8
Operating System, Sun StorEdge
Resource Management, Sun StorEdge
Utilization, and Sun StorEdge
Performance Suites |
Support Host Platforms
|
Suuported Hosts
Servers |
All Sun
Enterprise, Netra, and Sun Fire
SPARC-based and Sun Fire x86-based
servers; x86-based (Intel and AMD)
third-party servers; IBM RISC-based
servers; HP RISC-based servers |
|
Supported HBAs
|
Note: All non-Sun
host bus adapters supported by
third-party vendor. |
|
Sun Solaris
Operating Systems 8,9, 10
(SPARC-based) |
HBAs:
SG-XPCI2SCSI-LM320, (X)6758A;
(X)2222A; (X)4422A
|
|
Sun Solaris x86 9,
10 |
HBAs: (Sun Fire
V60x, V65x, V20z, V40z), X9265A;
SG-XPCI2SCSILM320; LSI Logic
LSI22320-R |
|
Red Hat Linux
AS3.0 |
HBAs: (Sun Fire
V60x, V65x, V20z, V40z), X9265A;
SG-XPCI2SCSILM320; LSI Logic
LSI22320-R |
|
Novell SuSE Linux
SLES 9 |
HBA:
SG-XPCI2SCSI-LM320 |
|
MS Windows NT EE
4.0/2000/2003 |
HBAs: X9265A;
SG-XPCI2SCSI-LM320; LSI Logic
LSI22320-R
|
|
Novell NetWare
5.1, 6.0, 6.5 |
HBAs: Adaptec
39160; Adaptec 39320 |
|
HP-UX 11i |
HBA: HP A6829A
(1st year on site, 2nd year return
to depot)
|
|
IBM-AIX 5.1L |
HBA: IBM
SYM53C1010 |
Reliability, Availability,
Serviceability (RAS)
|
RAS |
- Hot-swap RAID controllers
with battery-backed mirrored
512MB cache, (with dual RAID
controllers)
- 1x320MB SCSI host port (with
2 expansion trays) Up to twelve
hot-swap disk drives per RAID
array tray and per expansion
tray
- Dual hot-swap, redundant,
load-sharing power supplies with
dual independent AC inputs
- Hot-swap, redundant
electrically-isolated redundant
cooling fans
- Non-disruptive firmware
upgrades (with dual RAID
controllers via SSCS)
|
Electrical Requirements
|
Wattage |
420W each (Dual
Hot-Swap Redundant Power Supplies)
|
|
AC Voltage |
100 to 240 VAC,
single phase |
|
AC Power
requirement |
90 to 132 VAC, 180
to 264 VAC (47 to 63 Hz) |
|
AC Current per
input |
100 to 240 VAC, 50
to 60 Hz, 5.0¡V7.1A |
|
DC Voltage |
¡V48 or ¡V60 VDC,
18A |
|
DC Power
requirement |
¡V36 to ¡V75 VDC
|
|
DC Current per
input |
¡V48 or ¡V60 VDC,
18A |
Environment
|
¡@ |
Temperature |
- Operating: 5¢XC to 40¢XC (41¢XF
to 104¢XF)
- Nonoperating: ¡V40¢XC to 65¢XC
(¡V40¢XF to 149¢XF)
|
|
Humidity
(non-condensing) |
- Operating: 10% to 90%
relative to 38¢X
- Nonoperating: 0% to 90%
relative to 27¢XC
|
|
Altitude |
- Operating: ¡V30m to 3048m
(¡V100 to 10,000 ft.)
- Nonoperating: ¡V30m to
12,192m (¡V100 to 40,000 ft.)
|
|
Shock |
- Operating: 5.0 G, 11-ms,
half-sine
- Nonoperating: 15.0 G, 11-ms,
half-sine
|
|
Vibration |
- Operating: 0.2 G, 5¡V500 Hz,
swept-sine
- Nonoperating: 1.0 G, 5¡V500
Hz, swept-sine
|
|
Noise |
LWAD = 6.6 bels;
LWAD (1 bel = 10 dB) Declared noise
emissions in accordance with ISO
9296, measured at 23¢XC. |
Regulations
|
Safety |
UL listed UL
60950:2000, CSA-C22.2 No. 60950-00,
EN 60950:2000, IEC 60950, TUV, CB
Scheme, GOST-R Mark; S-Mark, FCC
Part 15 Class B, CISPR 22 55022:1998
Class B, ICES-003 |
|
Emissions |
VCCI Class B, EN
AS/NZS 3548:1996, BSMI CNS 13438
Class B, S Mark |
|
Harmonics |
IEC
61000-3-2:2000,
IEC1000-3-3:1995/A1:2001 |
|
Immunity |
CSIPR 24 EN 55024
|
|
Ruggedized |
NEBS Level 3
(GR-63-CORE; GR-1089-CORE),
MIL-STD-810F, ETSI EN 300 386 |
|
Restriction of
Hazardous Substances |
European Union
(EU) Directive 2002/95/EC, invoking
the ¡§lead-insolder¡¨ exemption,
Article 4(1) paragraph 7. |
Dimensions and Weight
|
Dimensions
(Height, Width, Depth) |
H: 8.8 cm (3.5
in.; 2RU); W: 44.7 cm (17.6 in.); D:
53.3 cm (21 in.) |
|
Weight (Fully
Populated) |
22.7 kg (50 lb.)
|
Warranty
|
Two year |
Sun two-year
standard warranty, (1st year on
site, 2nd year return to depot)
|
|
Service upgrades
|
SunSpectrum
service upgrades are available
|