Architecture
|
Architecture |
- Processor: One or two 1.3 UltraSPARC IIIi processors
- Architecture: 64-bit, four-way Superscaler SPARC V9
- Cache: 64-KB data, 32-KB instruction, and 1-MB
integrated L2
- Main memory: Four DIMM slots per processor, DDR PC2100
or faster registered ECC. System configuration from 1 GB to
8 GB
|
Standard/Integrated Interfaces
|
Network |
Four 10/100/1000 Base-T Ethernet |
|
Network Management |
One 10 Base-T Ethernet |
|
Serial |
One TIA/EIA-232-F (RJ45) port One
TIA/EIA-232-F asynchronous (DB9) port |
|
SCSI |
SCSI/USB: One Ultra160 SCSI multimode (SE/LVD).
Two OHCI 1.0-compliant interfaces, supporting dual speeds of
1.2- and 1.5-Mbits/sec. each
|
|
Ethernet |
One internal PCI 2.2-compliant expansion slot:
One 64-bit, 33/66-MHz 3.3 V full-length |
|
Alarms |
Four, dry-contact alarms (critical, major,
minor, and user)
|
|
System Configuration reader and card |
Front-accessible for transfer of system
configuration information, including host ID, MAC address, NVRAM
|
Mass Storage and Media
|
Internal disk |
Up to two hot-swap, SAS, 73-GB, 10K-RPM disks
|
|
Internal DVD |
Optional slim-line DVD+/- RW |
|
External disk |
Sun StorEdge 3000 Series, Sun StorEdge 6000
Series and 9900 Series (optional) |
|
External tape |
(LTO 2 and SDLT 320 versions): Sun StorEdge
L25 and Sun StorEdge L100 and L180 (optional) |
Software
|
Operating System |
Solaris 9 (update 8) OS and later, or Solaris
10 (03/05) OS and later. See Jan 4 Enterprise System |
|
Languages |
C/C++, FORTRAN, Java programming languages;
all other standard Sun-supported languages |
|
Networking |
ONC, NFS, TCP/IP, SunLink, OSI, MHS, IPX/SPX
|
|
Management |
SunVTS, SRS Net Connect, SRM, ALOM |
|
High Availability |
Sun Cluster 3.X, Netra HA Suite |
Power Supplies
|
AC power |
Typical system input power: 235 to 355 watts
depending on configuration.
Maximum Input Power (AC version): 460W (100VAC @ 4.6A)
Maximum Output Power (AC version): 320W
Maximum Power consumption: 1570 BTU/hr
Typical Power consumption: 1200 BTU/hr
Power Inputs: Single AC power input |
|
Power supply |
Dual DC power inputs, with typical system
input power at 200-300 W, depending on configuration¡X maximum
power input is 400 W, maximum power output is 320 W. Typical
power consumption is 1,365 BTU/hr., maximum power consumption is
1,025 BTU/hr. |
Environment
|
Power |
-40 V to -75 V DC (range), single or dual
power sources -48 V or -60 V DC (nominal) |
|
Operating temperature |
Long-term: 5-40 deg. C (41-104 deg. F), 5-85
percent RH noncondensing. Short-term: -5 to 55¢X C (23-131¢X F),
5-90 percent relative humidity noncondensing, but not exceeding
0.24 kg./water/kg. Dry air (0.053 lbs. water/2.205 lbs. dry air)
|
|
Nonoperating temperature |
-40¢X C to 70¢X C (-40¢X F to 158¢X F), up to 93
percent relative humidity, noncondensing, 38¢X C (100.4¢X F) max.
wet bulb |
|
Altitude |
Operating: -400m to 3,000m [-1,300 ft. to
9,850 ft.] Nonoperating: -400m to 12,000m [-1,300 ft. to 39,000
ft.] |
|
Acoustic noise |
Declared noise emissions in accordance with
ISO 9296¡Xoperating, 7.0 B; idling, 7.0 B. Meets ETSI EN
300-019-2-1, 2, 3, Table 3.1 and 3.1E. Except ¡V5¢X C cold start,
condensing humidity, and rain. Meets Seismic GR-63-CORE
requirements for earthquake Zone 4. |
Regulatory Agency Certifications
|
Regulatory Agency Certifications |
Product categories are information technology
and telecommunications network equipment. Safety certifications
include cULus, TUV GS, CB scheme with all national differences
CE, CCC, GOST R, S-MARK. EMC certifications include Class A FCC,
CE, VCCI, BSMI, C-Tick, MIC, CCC, GOST. Telecommunications (DC
only) Telecordia SR 3580 NEBS Level 3. |
Dimensions and Weight
|
Height |
43.6mm (1.72 in.), 1 RU |
|
Width |
425mm (16.3 in.), not including bezel, 442mm
(17.4 in.), including bezel |
|
Depth |
493mm (19.4 in.) to rear connectors |
|
Weight |
9.8 kg. (21.6 lb.) fully configured with DVD
and rackmount kit, not including PCI card |
|
Enclosure |
Enclosure fits into a standard 19-inch-wide
rack. Rack kit includes: 19-inch four-post slide and two-post
hard mount. Additional rack kits available: 24-inch four-post
slide, and 24-inch two-post hard mount. |
|
Upgrades |
Upgrades for the Netra 210 Server are
available through the SunSM Upgrade Advantage Program¡Xcontact
your local Sun sales representative for details |