RAID level | 0, 1, 0+1(10), 5, 6 | |||
---|---|---|---|---|
Storage capacity | For GlobalServer | With Fibre Channel disk drive | Physical capacity (*Note 1) | Max. 25.9TB |
Logical capacity (*Note 2) | Max. 11.2TB | |||
For UNIX/IA Server | With Fibre Channel disk drive | Physical capacity (*Note 1) | Max. 819TB | |
Logical capacity (*Note 3) | Max. 638TB | |||
With Nearline FC disk drive | Physical capacity (*Note 1) | Max. 1,365TB | ||
Logical capacity (*Note 3) | Max. 1,069TB | |||
Number of controllers | Max. 8 | |||
Host interface | Fibre Channel (Max. 4Gbit/sec), iSCSI (Max. 1Gbit/sec), OCLINK (Max. 17MB/sec), FCLINK (*Note 4) (Max. 2Gbit/sec) | |||
Number of host interfaces | FC | 16 to 128 | ||
iSCSI | 4 to 64 | |||
OCLINK | 4 to 64 | |||
FCLINK | 4 to 64 | |||
Cache capacity | Max. 256GB | |||
Number of drives | Max. 2,760 | |||
Disk drive | Fibre Channel disk drive | Drive capacity | 300GB/146GB/73GB (10,000rpm), 146GB/73GB/36GB (15,000rpm) | |
Drive interface | Fibre Channel (Max. 4Gbit/sec) | |||
Nearline FC disk drive | Drive capacity | 500GB (7,200rpm) | ||
Drive interface | Fibre Channel (Max. 2Gbit/sec) | |||
Dimensions (W x D x H) |
2,600 x 995 x 1,800mm
(Max. 10,040 x 995 x 1,800mm) |
|||
Weight | Max. 10,930kg | |||
Power requirements |
Voltage | 200 to 240VAC | ||
Phase | Single phase | |||
Frequency | 50 or 60Hz | |||
Power consumption | Max. 82,900W | |||
Heat dissipation | Max. 304,500kJ/h | |||
Environmental conditions |
Temperature | 5 to 35¢XC (operating), 0 to 50¢XC (non operating) | ||
Humidity | 20 to 80%RH (operating), 8 to 80%RH (non operating) |
*Note 2: Storage capacity is calculated as formatted for GlobalServer.
*Note 3: The logical capacity value was calculated as 1 Kbytes = 1,024 bytes when formatted as RAID 0+1
(RAID 10). User area capacity differs depending on the environment.
*Note 4: The data transfer speed between the ETERNUS8000 and the FCLINK switch.
¡@