Processor
|
Processor |
Combine up to four 1.8 GHz or 1.5GHz
UltraSPARC IV+ and/or 1.35GHz or 1.05 GHz UltraSPARC IV
processors |
|
Architecture |
Superscalar SPARC V9, ECC Protected |
|
Processor modules |
One or two dual processor/memory modules |
|
Cache per UltraSPARC IV+ processor |
- Level 1: 64-KB data and 64-KB instruction per pipeline
- Level 2: 2 MB shared on-chip
- Level 3: 32 MB shared external
|
Main Memory
|
Main Memory |
A system maximum of 64 GB when configured with
four processors
|
Standard Interfaces
|
Network |
Two 10/100/1000 Mbps Ethernet |
|
I/O |
FC-AL disk controller |
|
Serial |
RJ45 serial port |
|
Expansion capability |
Six PCI slots compliant with PCI specification
Revision 2.1 (2 @ 66 MHz, 64 bits wide, 3.3 volts; 4 @ 33 MHz,
64 bits wide, 5 volts) |
|
USB |
Two (compliant with USB Revision 1.0) |
Mass Storage
|
Host adapters |
Internal IDE (supports DVD and/or DVD R/W
drive) |
|
Internal disk |
Up to 2 3.5" x 1.0" 15K-RPM FC-AL disks
(146-GB capacity), providing a maximum total capacity of 292 GB
|
|
External disk |
- Sun StorageTek D240
- Sun StorageTek S1
- Sun StorageTek 3120
- Sun StorageTek 3310 SCSI RAID/JBOD
- Sun StorageTek 3320
- Sun StorageTek 3510 FC RAID/JBOD
- Sun StorageTek 3511
- Sun StorageTek 6140 Array
- Sun StorageTek 6920
- Sun StorageTek 9910/9960/9970/9980
|
|
External tape |
- Sun StorageTek DAT 72 desktop tape drive
- Sun StorageTek LT0-2 desktop tape drive
- Sun StorageTek LT0 2V desktop tape drive
- Sun StorageTek LT0-3 desktop tape drive
- Sun StorageTek SDLT 320 desktop tape drive
- Sun StorageTek SDLT 600 desktop tape drive
- Sun StorageTek C2
- Sun StorageTek C4
- Sun StorageTek SL500
- Sun StorageTek SL700/SL1400 tape library
- Sun StorageTek SL8500 tape library
|
Software
|
Operating system
(minimum version) |
- The minimum OS version for 1.5GHz and 1.8GHz UltraSPARC
IV+ processors is Solaris 9 9/05 or Solaris 10 3/05 HW1
- The minimum OS version for 1.35GHz and 1.05GHz
UltraSPARC IV processors is Solaris 8 2/04, Solaris 9 4/04,
or Solaris 10 3/05
|
|
Enterprise infrastructure software |
- Sun Java Enterprise System
- Sun Management Center
- Sun N1 System Manager
|
Power supplies
|
Power supplies |
Input per power supply/system of 1600 watts
(mfg. rating)
|
|
Maximum AC input |
1847 W per power supply |
|
Maximum DC output |
1448 W per power supply |
Environment
|
AC power |
200¡V240 VAC, 47¡V63 Hz, 2078 VA |
|
Operating temperature |
5¢X C to 35¢X C (41¢X F to 95¢X F), 20% to 80%
relative humidity, non condensing, 27¢X C max. wet bulb |
|
Non operating temperature |
-20¢X C to 60¢X C (-4¢X F to 140¢X F), 95%
relative humidity, non condensing |
Regulations
|
Regulations |
Meets or exceeds the following requirements:
|
|
Safety |
UL/CSA-60950-1, EN60950-1, IEC60950-1 CB
Scheme with all country deviations, IEC825-1, 2, CFR21 part
1040, CNS14336 |
|
Ergonomics |
EK1¡VITB¡V2000 |
|
RFI/EMC |
EN55022 Class A, 47 CFR 15B Class A, ICES
Class A, VCCI Class A, AS/NZ 3548 Class A, CNS 13438 Class A,
KSC 5858 Class A, GB 9254 Class A, EN61000-3-2, GB 17625.1,
EN61000-3-3 |
|
Immunity |
EN55024/CISPR24 |
|
Telecommunications |
EN300-386 |
|
X-ray (for monitors) |
DHHS 21 Subchapter J; PTB German X-ray Decree
|
|
Regulatory markings |
CE, FCC, ICES-003, C-tick, VCCI, GOST-R, BSMI,
MIC, UL/cUL, UL/S-mark |
|
Other |
Restriction of Hazardous Substances (RoHS)
directive 2002/95/EC
Labeled per Waste Electrical and Electronic Equipment (WEEE)
Directive
|
Key RAS Features
|
Key RAS Features |
- Hot-pluggable disk drives
- Redundant, hot-swappable power supplies
- Environmental monitoring and fault detection
- Automatic System Recovery (ASR) capabilities
- Remote Lights Out Management capability
- Dual-loop enabled FC-AL subsystem
- Support for disk and network multipathing with automatic
failover capability
- Error correction and parity checking for improved data
integrity
|
Trade in and Save
|
The Sun Upgrade Advantage Program |
The Sun Upgrade Advantage Program (UAP) offers
trade-in value for qualified Sun and competitive servers toward
the purchase of replacement Sun Fire V490 server(s). Whether
upgrading one system or consolidating many systems to one, Sun
UAP offers the flexibility to trade in and receive credit toward
the new Sun system purchased. Upgrades are also available for
Sun Fire server system components, including CPU/memory boards
and I/O. For more information visit
Sun Trade-In Programs
|
Dimensions and Weight
|
Height |
222 mm (8.75 in.) |
|
Width |
446 mm (17.5 in.) |
|
Depth |
610 mm (24.0 in.) |
|
Weight |
35.8 kg (79 lb.) (minimum)
44 kg (97 lb.) (maximum)
|
Warranty
|
Hardware support |
3 years |
|
Software install |
90 days |
|
Call response |
8 hours |
|
Deliver |
Next business day, on-site |