MODEL |
|
IMP-1025A/AP |
IMP-1200A/AP |
IMP-1500A/AP |
IMP-2000A/AP |
OUTPUT |
Voltage (on battery) |
Simulated sine wave at 100V / 110V /
115V / 120V or 220V / 230V / 240V +/- 5% |
Frequency (on battery) |
50 or 60 Hz +/-1Hz |
Voltage Regulation( AVR) |
AVR automatically increase output
voltage 15% above input voltage if -9% to -25% of nominal.
AVR decrease output voltage 13% below input voltage if +9% to +25% of
nominal |
Transfer Time |
4 milliseconds (Typical) |
INPUT |
Voltage |
100V / 110V / 115V / 120V or 220V /
230V / 240V +/- 25% at line input |
Frequency |
50 or 60 Hz +/- 10% (auto sensing) |
PROTECTION
& FILTERING |
Spike Protection |
1050 Joules |
Unit Input |
Breaker or fuse for overload & short
circuit protection |
Overload Protection |
UPS automatic power off if overload
exceeds 110% of nominal at 60 seconds and 130% at 3 seconds |
Telephone Protection |
RJ-11 (1 in 2 out*
or 1 in 1 out) compatible jacks for telephone surge protection. |
Ethernet Protection* |
RJ-45 compatible jacks for Ethernet
network surge protection |
Coaxial Protection |
F1 terminal for cable TV/modem surge
protection |
Short Circuit |
UPS output cut off immediately or
input fuse protection |
BATTERY |
Type |
Sealed, maintenance-free lead acid |
Typical Recharge Time |
6 hours (to 90% of full capacity) |
Back-up Time
(a PC with 15" monitor) |
about 50 MINs |
about 55 Mins |
about 60 MINs |
about 65 Mins |
Protection |
Auto discharge protection |
PHYSICAL |
Net Weight kg (lbs) |
13.4 (28.6) |
13.4 (28.6) |
13.6 (29.95) |
14.5 (31.93) |
Shipping Weight Kg (Ibs) |
14.8 (32.6) |
14.8 (32.6) |
15.0 (33.04) |
15.9 (35.02) |
Dimension WxDxH (mm) |
130 x 382 x 192 (5.1" x 15.0" x 7.6") |
Input Inlet |
IEC 320 power inlet |
Receptacles |
NEMA 5-15R (UPS outlets x 4 ,
Convenience outlets x 2 )
IEC 320 female appliance coupler
(UPS outlets 4 , Convenience outlets x 1 ) |
INTERFACE |
USB / RS-232 |
Detect battery low, Schedule UPS
on/off, AC input/output power status display |
ALARM |
Battery Back-up |
Slow beeping sound (about 0.47 Hz) |
Battery Low |
Rapid beeping sound (about 1.824 Hz) |
Overload |
Continuously beeping sound |
ENVIRONMENT |
Ambient Operation |
3,500 meters max, elevation. 0-95%
humidity non-condensing, 0-40 deg |
Audible Noise |
<40dBA (1 meter from surface) |
Storage Condition |
15,000 meter max. elevation |