|
|
¡@ |
Disk Performance |
Complete backup and recovery jobs on time with disk
performance. |
Simplified Scalability |
NetApp VTL simplifies management by providing up to 450TB
native capacity to minimize resource sprawl. |
Efficient, High-Speed Tape Integration |
Use 50% less tape and fulfill disaster recovery requirements
faster while extending the lifespan of current tape
resources through NetApp VTL Direct Tape Creation¡¦s
efficient tape media and drive usage. |
Advanced Application Integration |
10x faster restores (seconds vs. hours) through NetApp VTL
Shadow Tape(TM) integration with major backup applications.
Simplify integration of disk backup and use existing backup
strategies with our virtual tape interface, which is 100%
compatible with backup application media management. |
100% Technology Ownership and Common Hardware Platform |
Simplify management, monitoring, and upgrades through highly
scalable modular design based on 100% native NetApp
technology. Gain maximum investment protection through a
common architecture built on our years of storage expertise. |
Global Service and Support |
Simplify deployments and resolve issues faster with
professional services offerings, proactive alerting, and
24x7 NetApp support. |
|
NetApp NetApp VTL1400 - ServerBank¸ê°T±ÄÁʺô NetApp VTL1400 Àx¦s³]³Æ/³Æ¥÷¤è®×>ºÏºÐ°}¦CRAID>Fibre-to-SATA
¡@
²£«~³W®æ |
NetApp
VTL System Software |
VTL OS v5.x with
hardware compression (Note: VTL OS 6.x is no
longer recommended for new deployments). |
Standard
Software Features |
Multiple virtual
drives, multiple virtual libraries, built-in
data mover for direct VTL-to-physical tape
creation, Tape Smart Sizing, Shadow Tapes, and
AutoSupport. |
Hardware
Features |
Dual-core
processors, built-in hardware compression, 4
GB/s Fibre Channel ports onboard, full-duplex
10/100/1000 Base-T Ethernet management port,
Compact Flash, redundant hot-plug cooling fans,
redundant hot-plug power supplies, 19"
rack-mount enclosure, optional 220V 42U 19"
system cabinet. |
RAID
Protection |
VTL-RAID (single
parity). For maximum data protection, all
backups to the VTL should be copied to physical
tape. |
Hot
Spares Drives |
User defined
global hot spare drives. |
Capacity
Expansion Option |
DS14mk2 disk
shelf with 1 TB SATA drives. |
|
|
Guidelines
for Maximum Weekly Ingest of Backup Data |
|
|
|
VTLOS 5.x, no tape
creation |
150 TB/wk |
315 TB/wk |
630 TB/wk |
VTLOS 5.x, with tape
creation |
125 TB/wk |
175 TB/wk |
350 TB/wk |
VTLOS 6.x with
deduplication enabled 3 |
28 TB/wk |
35 TB/wk |
70 TB/wk |
Peak
Aggregate Write Throughput |
|
|
|
VTLOS 5.x (100%
writes) |
600 MB/s |
1150 MB/s |
2300 MB/s |
VTLOS 5.x (concurrent
read/write workload w/50% writes) |
340 MB/s |
650 MB/s |
1300 MB/s |
VTLOS 6.x
(default settings, 100% writes) 3 |
300 MB/s |
380 MB/s |
760 MB/s |
VTLOS 6.x
(default settings, concurrent read/write workload) 3 |
170 MB/s |
215 MB/s |
430 MB/s |
Peak Single
Stream Write Throughput |
|
|
|
VTLOS 5.x 4 |
100 MB/s |
100 MB/s |
100 MB/s |
VTLOS 6.x 3,
4 |
70 MB/s |
70MB/s |
70MB/s |
Peak
Aggregate Read Throughput |
|
|
|
VTLOS 5.x |
450 TB |
900 TB |
1800 TB |
VTLOS 6.x 3 |
variable |
variable |
variable |
Maximum Raw
Capacity |
55 TB |
275 TB |
550 TB |
Maximum
Effective Capacity |
|
|
|
VTLOS 5.x with
standard compression @ 2:1 |
90 TB |
450 TB |
900 TB |
VTLOS 6.x with
deduplication enabled 3 |
variable |
variable |
variable |
Maximum
Number of Virtual Tapes |
|
|
|
Displayable in GUI
per virtual library |
1000 |
1000 |
1000 |
Total per system |
10,000 |
10,000 |
20,000 |
Maximum
User Data Per Virtual Tape 4 |
2 TB |
2 TB |
2 TB |
Maximum
Number of Virtual Libraries |
256 |
256 |
512 |
Maximum
Number of Virtual Drives |
1,500 |
1,500 |
1,500 |
Maximum
Concurrent In-use Virtual Drives |
¡@ |
¡@ |
¡@ |
VTLOS 5.x, no Tape Creation5 |
90 |
90 |
180 |
VTLOS 5.x, with
Tape Creation 5 |
45 |
45 |
90 |
VTLOS 6.x with
deduplication enabled, no tape creation 3,
5 |
80 |
80 |
160 |
VTLOS 6.x with
deduplication enabled with tape creation 3,
5 |
40 |
40 |
80 |
Notes |
|
1 Specifications
provided are based on lab testing of maximum configurations
for compression cards, disk shelves and backend ports.
Actual results for each customer environment will vary based
upon a number of factors. Maximum performance and capacity
are calculated using Base10 arithmetic (i.e.
1TB=1,000,000,000,000 Bytes) and data that compresses at a
ratio of 2-to-1. |
2 A
VTL1400 is the equivalent of two, independent VTL700
systems. |
3 VTL
OS 6.x is a restricted access release and is no longer
recommended for new deployments. Space savings from VTL
deduplication will vary based on a number of factors and may
not provide any benefits versus standard compression,
depending upon the environment. Read performance for a
system running VTL deduplication will also vary based upon a
number variables. |
4 Applies
to VTL OS releases 5.6.2 and 6.0.3 and higher, only |
5 Maximum
in-use concurrent virtual drives equals the maximum number
of simultaneous backup streams per system and can be
affected by use case, configuration settings, and concurrent
operations. Maximum values for the tape creation use cases
assume that all virtual drives are cloning to physical tape
drives concurrently. |
Disclaimer |
These specifications are
based on internal testing and are not intended to reflect
the actual results that can be achieved in any particular
user¡¦s environment. NetApp is not responsible for any
incidental or consequential damages in connection with the
furnishing, application, or use of this information. These
specifications are subject to change without notice. |
|
AC
Power/Current (line voltage for standalone systems
depends on local power distribution; system cabinets
are 200 to 240 VAC only) |
100 to 240 VAC, 3.83
to 1.75A, 50/60Hz
200 to 240 VAC, 2.00 to 1.75 A, 50/60 Hz |
100 to 240 VAC, 7.66
to 3.50 A, 50/60 Hz |
Thermal
Rating
Typical
Maximum |
1233 Btu/hr
1365 Btu/hr |
2466 Btu/hr
2730 Btu/hr |
Weight |
75 lb (34 kg)
Fully configured |
150 lb (68 kg)
Fully configured |
Height |
5.12" (13 cm)
3U EIA |
10.6" (26 cm)
6U EIA |
Width |
19" IEC
rack-compliant (17.7", 44.9 cm) |
Depth |
24" (61 cm) without
cable management tray
30" (76.2 cm) with cable management tray |
Operating
Temperature, Altitude, and Relative Humidity |
10¢X C to 40¢X C (50¢X F
to 104¢X F); at </= 3,000 m (at </= 10,000)
elevation; 20% to 80% relative humidity,
non-condensing (28¢X C wet bulb temperature) |
Non-operating
Temperature and Relative Humidity |
-40¢X C to 65¢X C (-40¢X
F to 149¢X F); 10% to 95% relative humidity,
non-condensing, in original container |
Operating
Acoustic Noise |
= 54 dBA sound
pressure (LpA) at normal operating conditions (at
22¢X C and at sea level) |
Min. Cabinet
Clearances for Airflow |
10" (25.4 cm) in
front, 12" (30.5 cm) in rear |
Min. Service
Clearances for Service |
30" (76.2 cm) in
front, 30" (76.2 cm) in rear |
Altitude |
10,000 ft maximum |
|
|
Disk Drive
Storage Shelf |
DiskShelf14 family -
DS14mk2AT; each w/14 low-profile slots for SATA disk
drives |
Disk Drive
Storage Shelf Interface |
PCI-based Fibre
Channel-Arbitrated Loop (FC-AL) |
Power
Supply/Cooling Fans |
Dual, redundant,
hot-pluggable, integrated power supply/fan
assemblies (220V/110V) |
AC Power/Max.
Current |
100 to 120 VAC/3.95A;
200 to 240 VAC/1.9A |
Operating
Temperature and Relative Humidity |
10¢X C to 40¢X C (50¢X F
to 104¢X F); 10 % to 95 % relative humidity,
noncondensing |
Nonoperating
Temperature and Relative Humidity |
-40¢X C to 65¢X C (-40¢X
F to 149¢X F); 10% to 95 % relative humidity,
noncondensing |
Thermal
Rating |
1017 Btu/hr (fully
loaded shelf) |
Operating
Acoustic Noise |
49 dBA at 1m at 23¢X C |
Dimensions
(Height/Width/Depth) |
3U EIA (5.25", 13.3
cm)/19" IEC rack-compliant (17.6", 44.7 cm)/20"
(50.85 cm) |
Weight |
77 lb (35 kg) fully
loaded |
|
|
20 A and 30 A
Single Phase Cabinets
20 A Cabinet - Includes 4 Power Cords with NEMA
L6-20 or IEC 309 or Australia AS/NZ53123-20
Connectors
30 A Cabinet - Includes 2 Power Cords with NEMA
L6-30 or IEC 309 connectors |
20 A Cabinet - 1 controller and 13 DS14-type
shelves; 2 controllers and 12 DS14-type shelves
30 A Cabinet - 1 controller and 12 DS14-type
shelves; 2 controllers and 11 DS-14 type shelves |
AC Power |
200 to 240 VAC |
Current |
20 A Cabinet -
mdash;Maximum 32 A total
30 A Cabinet - Maximum 24 A total |
Dimensions
(Height/Width/Depth) |
78.75" (200 cm)/23.6"
(60 cm)/37.4" (95 cm) |
Min.
Clearances |
48" (122 cm) front
and rear |
Shipping
Height |
90.6" (230 cm) |
Weight
(Empty) |
275 lb (125 kg) |
|
|
FAS Safety |
EN 60950, CE, CSA
60950, UL 60950, CB IEC60950-1 (all national
deviations), EN60825-1, IRAM, GOST-R, BSMI |
Disk Shelf
Safety |
EN 60950, CE, CSA
60950, UL 60950, CB IEC60950-1 (all national
deviations), EN60825-1, IRAM, GOST-R, BSMI |
Emissions |
FCC Part 15 Class A,
ICES-03, CE, MIC, VCCI, AS/NZS CISPR 22, EN55022,
EN61000-3-2, EN61000-3-3, CoC (South Africa), BSMI |
Immunity |
EN 55024 |
|
¡D¥»¤å¥óªº¸ê°TY¦³×§ï¡A®¤¤£¥t¦æ³qª¾¡C
¡D³W®æ©Î³ø»ùY¦³»~¡A¥Hì¼t«¬¿ý©Î¥¿¦¡³ø»ù³æ¬°¥D¡C
¡D¥»ºô¯¸¤º®e©Î¤å¥ó·í¤¤©Ò´£¤Î¤§«~µP¤Î²£«~¦WºÙ©Î¹Ï¤ù§¡¬°¨äì©ÒÄݤ½¥q¤§ª©Åv¡B°Ó¼Ð©Îµù¥U°Ó¼Ð¡C
º¡¤@©w¼Æ¶q©Îª÷ÃBÁÙ¦³¦h´ÚÃØ«~¥i¨Ñ¿ï¾Ü³á!
ServerBank ¤O±ô¸ê°Tµ¹§A³Ì¶WÈÀu´fªºNetApp - NetApp VTL1400 - Àx¦s³]³Æ/³Æ¥÷¤è®×>
,³Ì¦nªºNetApp - NetApp VTL1400±ÄÁÊ¿ï¾Ü´N¦b ServerBank!
|
¥æ©ö¤è¦¡¡G
±z¤£½T©w¥H¤W°Ó«~¬O§_²Å¦X±zªº»Ý¨D?¨SÃö«Y¡A§ÚÌ·|¬°±z¦Vì¼t½T»{¡C©Î¬O±z§Æ±æ¼W´î¥H¤W°Ó«~¤§³W®æ¹s²Õ¥ó¡A§Ú̳£¥i¼u©Ê°t¦X±zªº»Ýn³ø»ù¤Î¥X³f¡C ¦p±z¹ï¥H¤W²£«~³W®æ¥H¤Î»ù®æº¡·N¡A¥i³z¹L¥H¤U¤è¦¡¶i¦æ±ÄÁÊ¡G
1.¹q¸ÜÁpô¡G ½Ðª½±µ¨Ó¹q¡G(02)8969-0901 |
2.ºô¸ô¸ß»ù¡GÂI¿ï¥»¶ÁʶR¸ß»ù§ÚÌ·|¥ß§Y»P±zÁpô! |
3.¨Ó¨ç¸ß»ùEmail: service@serverbank.com.tw |
|
¥I´Ú¤è¦¡¡G¦p«È¤á¬°º¦¸¥æ©ö±Ä²{ª÷¥æ©ö¡C |
¶Ç¯uq³æ¡G ª½±µ±N¥¿¦¡³ø»ù³æñ¦W«á¶Ç¯u¦Ü(02)2253-9016 §Y§¹¦¨qÁʵ{§Ç¡A§ÚÌ·|©ó³Ìµu®É¶¡¤º¹q¸Ü½T»{q³æ¡C |
±H°e®É¶¡¡G¨Ì³y¤£¦P¼tµP¥N²z°Ó¦³©Ò¤£¦P¡A¤j¦h¼Æ°Ó«~©ó 7 Ó¤u§@¤Ñ¯à°e©è«È¤áºÝ¡A§Ú̦¬¨ì±zq³æ®É·|¦P®É¦^Âбz½T©w¥æ´Á¡C |
°e³f¤è¦¡¡G(1) ì¼t©Î¬O¥N²z°Óª½±µ°t°e (2) ¥ÑServerBank©e°U¦v°t©Î¬O³f¹B¤½¥q°e¹F¡C |
°e³f½d³ò¡G¥xÆW¥»®q¦a°Ï¡A¹B¶O¥Ñ ServerBank ¬°±zt¾á¡Aª`·N¡I¦¬¥ó¦a§}½Ð¤Å¬°¶l¬F«H½c¡C |
°â«áªA°È¡GY²£«~¥»¨·å²«©Î¹B°e¹Lµ{¾ÉP·s«~·å²«¡A¨ì³f7¤é¤º¥i§ó´«·s«~¡C |
«O©T¬Fµ¦¡G ¹ê»Ú¥Hì¼t¤Î¥N²z°Ó¤½§i«O©T±ø¥ó¬°¥D¡A¬d¾\Áʪ«»¡©ú»P«O©TªA°È¡C |
¤O±ô¸ê°T ServerBank Inc. ²¤¶
¥Ø«e¤w¸g¬°¶W¹L30000®a¥ø·~´£¨ÑIT¸ê°T¬[ºc©Ò»Ýªº³nµwÅé³]³Æ¡A¦U¦æ·~ª¾¦W«È¤á¦p¡G
»s³y·~¡G¥x¿n¹q¡B¤Í¹F¡BÂE®üºë±K¡B¤O´¹¥b¾ÉÅé¡B¦w±¶Û¡B¥xÆWªFªÛ¡B¥xÆW^¸â¡B¥¿´Q¡B§¡»¨¡B§»¥¿¡B©MºÓÁp¦X¡BªF¶©¡B«Ø¿³¹q¤l¡B¸§Q®ú©úùÖ¡B®õª÷Ä_¡B¯«³q¡B¯«¹F¡B°¶³Ð¤O¡B±d¥þ¡B°ê²³¡B±á¬P¥b¾ÉÅé¡B¼s¹F¹q¸£¡B¼s¿o¹q³q¡BÁpµØ®ðÅé¡BÄ_¦¨¤u·~¡B¼s¹B¡B
¥~°Ó¡G ¥xÆWNTT¡B¥xÆW·Nªk¥b¾ÉÅé¡B¥xÆWNEW Balance¡B¥xÆWNEC¡B¥xÆWSONY¡B¥xÆW´I¤h¥þ¸S¡B
ª÷¿Ä¡G°ê®õ¤H¹Ø¡B¤¸¤jÃÒ¨é¡B«n¤s¤H¹Ø¡B°ê®õ¥@µØ¡B¥xÆW¤u·~»È¦æ¡B¥xÆWª÷¿Ä¬ã°V°|¡B¤T°Ó¬ü¨¹¤H¹Ø¡B¤j¸Û«OÀI¡Bªk°ê¤Ú¾¤¤H¹Ø¡B«O¸Û¤H¹Ø¡B°êµØ¤H¹Ø¡B²Î¤@ÃÒ¨é¡B´I¨¹¤H¹Ø¡BµØ«n²£ª««OÀI¡B·s¥ú¤H¹Ø¡B¥xÆW²£·~«OÀI¡B
¬y³q¡G ·s¥ú¤T¶V¡B¤T¹´(·L·¼s³õ)¡B«H¸q©Ð«Î¡Bªü¨½¤Ú¤Ú¡B
Æ[¥ú¡G ¤¤«H¶º©±¡B¶³®Ô¶º©±¡B¤Ó¥¬v¡BµØ®õ¡B¤»ºÖ¡B¤Ñ²»´¹µØ¡B¬K¤Ñ°s©±¡B»·¶¯®ü¬v¤½¶é¡B
¹«~¡G ¥xÆWµÒ°s¡B¤Ñ¤¯¯ù¸¡B¤¸¯ª¡B¥ú¬u¡B·sªF¶§¡B¦w¤ß¹«~(¼¯´µº~³ù)¡B®õ¤s¡B®üÅQ¤ý¡B²Î¤@¥ø·~¡B¾ó¤ì±í¡B¯ø´µ¸ª¡B«¢¸ò¹F´µ¦B²N²O¡B
´CÅé¡G ³ü¶Ç´C¡BÁp¦X³ø¡B¥xµø¡BµØµø¡B«D¤Z¹qµø¡B¨È¬w¼s¼½¡B¸ºÐ¼s¼½¡B·¼é°Û¤ù¡B®É³ø©P¥Z¡B
±Ð¨|¡G ¥xÆW¤j¾Ç¡B¥æ³q¤j¾Ç¡B²MµØ¤j¾Ç¡B¤j¦P¤j¾Ç¡B¤¤¥¡¤j¾Ç¡B¤¤ì¤j¾Ç¡B¤¤¿³¤j¾Ç¡B»²¤j¡B°ê»y¹ê¤p¡BÂù¶é°ê¤p¡BµØ¿³¤¤¾Ç¡BªFªù°ê¤p¡B¥x¬ì¤j¡B©ú§Ó¡BªF§d¡BªF®ü¹qºâ¤¤¤ß¡Bªø©°¤j¾Ç¡B«n¨È§Þ³N¾Ç°|¡B¨ÈªF¡B«nªù°ê¤¤¡B¥x®v¤j¡BªFµØ¡B¶§©ú¡B¶³¬ì¤j¡B¦Ë®v¡Bº[«n¤j¾Ç¡B±X¤s¬ì¤j¡B²H¦¿¡B²M¶³¡B³{¥Ò¡B
²Õ´¡G «H«O°òª÷¡B«C³Ð·|¡B¤¤¤p¥ø·~¨ó·|¡BºÞ²z¬ì¾Ç¾Ç·|¡Bì¦í¥Á±Ú¤å¤Æ±Ð¨|¨ó·|¡B¸êµ¦·|¡B¥xºô¤¤¤ß¡B¶³ªù»R¶°
¬F©²¡G ¤¤¬ã°|¡B¤¤¬ì°|¡B°·«O§½¡B¤Ñ¤å¬ì±ÐÀ]¡B¦Á¤îĵ§½¡BªO¾ô¹A·|¡B¥x¥_¿¤®ø¨¾§½¡B°ê½Ã°|¡B®ü¥ÍÀ]¡B°ê¦w§½¡B
ÂåÀø¡G ¥x¤jÂå°|¡B®¦¥D¤½Âå°|¡B¥_¨Ê¦P¤¯°ó¡B®H¨½°ò·þ±ÐÂå°|¡B¸¯Äõ¯À¥v§J¡Bù¤ó¤jÃļt¡B¥Ã«HÃÄ«~¡B
¹q«H¡G ¤j²³¹q«H¡B¥xÆW©Tºô¡B»·¶Ç¹q«H¡B
¥æ³q¡G ¥x¥_±¶¹B¤½¥q¡BµØ¯è¡B¤±]±¶¹B¡B¥xÆW´¼¼z¥d¡B
¤½¯q¡G³ßéw¨à¡B¥ì¨l¡B¶§¥ú°òª÷·|¡B»Z¤½^¡B¿ßÀYÆN
©v±Ð¡G ¤¤¥xÁI¦x¡B°ò·þ±Ð¦æ¹D·|¡B°ò·þ±Ð®û«H·|¡B
x¤è¡G ªÅx¥q¥O³¡¡B°ê¨¾Âå¾Ç°|¡B
|
|
|
|
|
|
|