Processor
|
Number of processors |
4, 8, or 12 1.2GHz Ultra SPARC III Cu
Processors |
|
Architecture |
Superscalar SPARC® V9, UltraSPARC® III Cu
architecture
|
|
Cache per processor |
Level 1: Parity-protected 32 KB instruction
and 64 KB data on chip (single-bit errors are corrected) Level
2: 8 MB external cache |
|
System Bus |
Sun Fireplane interconnect at 9.6 GBps,
sustained |
System
|
Main Memory |
8 GB to 96 GB |
|
I/O |
6 short PCI slots (64 bit; one at 66 MHz, 5 at
33 MHz)
|
|
System Controller |
Integrated Ultra3 SCSI supports up to 15 SCSI
devices |
|
Hard Disk |
Two 73 GB disks Ultra3 SCSI internal disks
|
|
Network connectivity |
Two integrated Gigabit Ethernet ports (66 MHz)
|
|
Removable media |
DVD-ROM internal drive DDS-4 tape drive
(optional) |
Availability
|
Availability Details |
Dynamic Reconfiguration of CPU/memory boards,
hot CPU upgrades, redundant Sun Fireplane interconnect,
redundant network connections, hot-swap disks, smart fans, 2N
redundant hot-swap power supplies, hardened Operating System
Kernel, hardened I/O drivers, systems configuration card,
proactive self diagnostics, end-to-end data integrity including
ECC, and cluster support.
|
Resources
|
Resource Management |
Solaris Resource Manager, Solaris Bandwidth
Manager |
Software
|
Operating System |
Solaris 8, Solaris 9 and Solaris 10 |
|
Languages |
C, C++, Pascal, Fortran, Java |
|
Networking |
ONC/NFS, TCP/IP, SunLink OSI, X.25, DCE,
NetWare |
|
System monitoring |
Sun Management Center 3.0, Solaris Management
Console |
|
System and network management |
Sun Cluster, Sun OpenBoot firmware, Solaris
Web Start, Solstice DiskSuite, SunScreen Secure Net, Power On
Self Test (POST), SunVTS, Solaris WBEM Services |
|
System and network management |
Sun Cluster, Sun OpenBoot firmware, Solaris
Web Start, Solstice DiskSuite, SunScreen Secure Net, Power On
Self Test (POST), SunVTS, Solaris WBEM Services |
Environment
|
AC power |
200-240V single-phase AC, 47-63-Hz |
|
Operating |
5¢X C to 35¢X C (41¢X F to 95¢X F) at 10% to 80%
humidity, noncondensing |
|
Altitude |
Up to 3,048 m (10,000 ft.) |
Regulations
|
Safety |
North America: UL 60950 third edition, CSA
C22.2 No 60950-00 third edition (Certified: UL and UL for
Canada) European Community: EN 60950:2000 (Certified: UL for
Germany/GS-Mark and GOST R for Russia) Worldwide except North
America: IEC 60950:1999 and CB Bulletin (Certified: DEMKO and UL
for Argentina/IRAM S-Mark) |
|
Immunity |
EN55024, i.e. EN61000-4-2, EN61000-4-3,
EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, and
EN61000-4-11 |
|
RFI/EMI FCC Immunity |
Class A: Australia/New Zealand AS/ NZ 3548,
Industry Canada ICES-003, European Community EN55022/CISPR22,
Japan VCCI, Taiwan CNS 13438, and US FCC 47CFR15.B) |
Dimensions and Weight
|
Height |
527 mm (20.75 in.), 12 rack units |
|
Width |
445 mm (17.5 in.) |
|
Depth |
558 mm (22 in.) |
|
Weight |
114 kg (251 lb.) fully loaded |
Scalability
|
Upgrades |
The
Sun Upgrade Advantage Program (UAP) offers trade-in value
for qualified Sun and competitive servers towards the purchase
of replacement Sun Fire V1280 servers. Whether upgrading one
system or consolidating many systems to one, Sun UAP offers the
flexibility to trade-in systems and receive credit towards the
new Sun system purchased. Upgrades are also available for Sun
Fire server system component upgrades including CPU/memory
boards, and I/O assemblies |