Chassis |
One-Rack-Unit (1RU) chassis |
CPU |
¡´ One
or two 3 rd Gen
AMD EPYC CPUs
|
Memory |
¡´ 32
DIMM slots (16 DIMMs per CPU socket), 3200 MHZ DDR4
¡´ Up
to 4 TB of capacity
|
Multi-bit error protection |
This server supports multi-bit error protection. |
Video |
The Cisco Integrated Management Controller (Cisco IMC) provides
video using the Matrox- G200e video/graphics controller:
¡´ Integrated
2D graphics core with hardware acceleration
¡´ Embedded
DDR memory interface supports up to 512 MB of addressable
memory (8 MB is allocated by default to video memory)
¡´ Supports
display resolutions up to 1920 x 1200 16 bpp @ 60 Hz
¡´ High-speed,
integrated 24-bit RAMDAC
¡´ Single-lane
PCI-Express host interface running at Gen 1 speed
|
Power subsystem |
Up to two of the following hot-swappable power supplies:
¡´ 1050
W (AC)
¡´ 1050
W (DC)
¡´ 1600
W (AC)
¡´ 2300
W (AC)
One power supply is mandatory; one more can be added for 1 + 1
redundancy. |
Front panel |
A front-panel controller provides status indications and control
buttons. |
ACPI |
This server supports the Advanced Configuration and Power
Interface (ACPI) 4.0 standard. |
Fans |
Eight hot-swappable fans for front-to-rear cooling |
InfiniBand |
The InfiniBand architecture is supported by the PCIe slots. |
Expansion slots |
Three half-height riser slots
¡´ Riser
1 (controlled by CPU 1):
◦ One
x16 PCIe Gen 4.0 slot (Cisco VIC), half-height, 3/4 length
¡´ Riser
2 (controlled by CPU 1):
◦ One
x8 PCIe Gen 4.0 slot, half-height, 3/4 length
¡´ Riser
3 (controlled by CPU 1):
◦ One
x16 PCIe Gen 4.0 slot (Cisco VIC), half-height, 3/4 length
OR
Two full-height riser slots
¡´ Riser
1 (controlled by CPU 1):
◦ One
x16 PCIe Gen 4.0 slot (Cisco VIC), full-height, 3/4 length
¡´ Riser
2 (controlled by CPU 1):
◦ One
x16 PCIe Gen 4.0 slot (Cisco VIC), full-height, 3/4 length |
Interfaces |
Rear panel:
¡´ One
1GBASE-T RJ-45 management port
¡´ One
RS-232 serial port (RJ45 connector)
¡´ One
DB15 VGA connector
¡´ Two
USB 3.0 port connectors
¡´ One
flexible modular LAN-on-motherboard (mLOM) / OCP 3.0 slot
that can accommodate various interface cards
Front panel:
¡´ One
KVM console connector (supplies two USB 2.0 connectors, one
VGA DB15 video connector, and one serial port (RS232) RJ45
connector)
|
Internal storage devices |
Drive storage:
Drives are installed into front-panel drive bays, which provide
hot-swappable access for SAS/SATA drives. The node is orderable
in two different versions:
¡´ HX225c
Edge M6 All Flash node (HXAF-E-225M6S)
◦ Data
drives: 3 to 6 SATA SSD
◦ Cache
drive: 1 SATA SSD
◦ Logging
drive: 1 SATA SSD
¡´ HX225c
Edge M6 Node (hybrid) (HX-E-225M6S)
◦ Data
drives: 3 to 6 SAS HDD
◦ Cache
drive: 1 SATA SSD/SAS SSD
◦ Logging
drive: 1 SATA SSD |
Integrated management controller |
A Baseboard Management Controller (BMC) runs Cisco Integrated
Management Controller (Cisco IMC) firmware.
Depending on your settings, the controller can be accessed
through the 1-GE dedicated management port or a Cisco Virtual
Interface Card (VIC).
Cisco IMC manages certain components within the server, such as
the Cisco 12G SAS HBA. |
Storage controllers |
Cisco 12G SAS HBA:
¡´ No
RAID support
¡´ JBOD/passthrough
mode support
¡´ Supports
up to 16 SAS/SATA internal drives
¡´ Plugs
into a dedicated slot
|
Modular LAN on motherboard (mLOM) / Open Compute Project (OCP)
3.0 slot |
The dedicated mLOM/OCP 3.0 slot on the motherboard can flexibly
accommodate the following cards:
¡´ Cisco
Virtual Interface Cards (VICs)
¡´ OCP
3.0 network interface card (UCSC-O-ID10GC)
|
Cisco Intersight |
Cisco Intersight provides server management capabilities.
Note: Cisco UCS Manager support is not available for this
server. |
Cisco Integrated Management Controller |
Requires Release 4.2(1) or later |
Operating temperature |
Minimum 10¢XC to 35¢XC (50¢XF to 95¢XF) with no direct sunlight (If
any A10, A100, or rear HDDs are installed, the 35¢XC (50¢XF)
restriction changes to 30¢XC (86¢X F).)
Maximum allowable operating temperature derated
1C/300 m (1F/547 ft) above 950 m (3117 ft) |
Extended operating temperature |
5¢XC to 40¢XC (41¢XF to 104¢XF) with no direct sunlight
Maximum allowable operating temperature derated 1C/175 m (1F/319
ft) above 950 m (3117 ft)
5¢XC to 4¢X5C (41¢XF to 113¢XF) with no direct sunlight
Maximum allowable operating temperature derated 1C/125 m (1F/228
ft) above 950 m (3117 ft)
System performance may be impacted when operating in the
extended operating temperature range.
Operation above 40¢XC is limited to less than 1% of annual
operating hours.
Hardware configuration limits apply to extended operating
temperature range. |
Nonoperating temperature |
Below -40¢XC or above 65¢XC (below -40¢XF or above 149¢XF)
Maximum rate of change (operating and nonoperating)
20¢XC/hr (36¢XF/hr) |
Operating relative humidity |
8% to 90% and 24¢XC (75¢XF) maximum dew-point temperature,
noncondensing environment |
Nonoperating relative humidity |
5% to 95% and 33¢XC (91¢XF) maximum dew-point temperature,
noncondensing environment |
Operating altitude |
0 m to 3050 m {10,000 ft) |
Nonoperating altitude |
Below 0 m or above 12,000 m (39,370 ft) |
Software |
¡´ Cisco
HyperFlex HX Data Platform Software (software subscription,
Edge license)
|