Performance data
|
¡@ |
Sun Fire X2100 |
Sun Fire X2100 M2 |
Processor |
One AMD Opteron model 100 Series processor,
single-core (models 146 (2.0 GHz), 148 (2.2 GHz), 152 (2.6 GHz),
154 (2.8 GHz) 156 (3.0 GHz) or dual-core (models 180 (2.4 GHz),
185 (2.6 GHz)) |
One dual core Next-Generation AMD Opteron
model 1200 Series (models 1218 (2.6 GHz), 1214 (2.2 GHz), 1210
(1.8 GHz) |
|
Memory |
Up to 8 GB; 4 DIMM slots, DDR1/400 Unbuffered
ECC DIMMs (128 bit plus ECC databus), 512 MB, 1 GB, 2 GB DIMMs
supported, installed in pairs |
Up to 8 GB; 4 DIMM slots, DDR2/667 Unbuffered
ECC DIMMs (128 bit plus ECC databus), 512 MB, 1 GB, 2 GB DIMMs
supported, installed in pairs
|
|
Networking |
Two Integrated 10/100/1000Base-T Ethernet
ports |
Four Integrated 10/100/1000Base-T Ethernet
ports |
|
PCI Slots |
1x 8-lane PCI-Express |
2x 8-lane PCI-Express |
Mass Storage
|
¡@ |
Sun Fire X2100 |
Sun Fire X2100 M2 |
Internal disk |
Up to two hot-pluggable 3.5" SATA disk drives;
80 GB, 250 GB, 500 GB 7200 rpm supported |
Up to two hot-pluggable 3.5" SATA II or SAS
disk drives; 250 GB, 500 GB 7200 rpm SATA II or 146 GB 15K rpm
SAS supported |
|
Removable Media |
Up to one EIDE DVD-ROM drive |
Up to one EIDE DVD-ROM or DVD+/-RW DL drive
|
|
RAID |
RAID 0/1 onboard, OS dependent* |
RAID 0/1/0+1 with optional 4-port SAS HBA; all
supported operating systems with SATA II or SAS drives |
|
External Storage |
Supported Storage |
|
Option Cards |
Sun has interoperability tested
and supports
a full suite of 4 GB and 2 GB Host Bus Adapters (HBAs).
These HBAs offer unique features and benefits including Solaris
integration and heterogeneous OS support. In the case of a
Solaris environment, Sun HBAs combined with Sun Solaris OS
provide the fastest, most reliable failover, highest
availability, increased performance and dynamic load balancing
by utilizing the Solaris SAN Foundation Suite drivers.
X2100 I/O page |
Software
|
¡@ |
Sun Fire X2100 |
Sun Fire X2100 M2 |
Operating Systems |
Solaris OS, Red Hat Enterprise
Linux, SUSE Linux Enterprise Server, and Microsoft Windows.
See
supported Operating Systems.
|
|
Languages |
C/C++, FORTRAN (Solaris 10 OS),
the Java programming language, all other standard Sun-supported
languages |
|
Networking |
ONC, ONC+, NFS, WebNFS, TCP/IP,
SunLink software, OSI, MHS, IPX/SPX, SMB technologies, XML |
|
Management |
System Management Daughter Card (SMDC),
standard on some configurations and optional on others.
Provides IPMI 1.5 in-band and out-of-band management.
For more information on the X2100 SMDCs capabilities and usage
guidelines, see the Service Processor (SMDC) section in the
Product Release notes (819-3722-15) or Appendix C in the
Sun Fire X2100 Server User Guide (819-3721-11) |
Service processor with embedded Lights Out
Management (LOM) standard.
Provides IPMI 2.0 in-band and out-of-band management.
Service processor is functionally equivalent to the ILOM used in
the Sun Fire X4100 and X4200 servers. |
Management
|
¡@ |
Sun Fire X2100 |
Sun Fire X2100 M2 |
Feature |
Optional System Management Daughter Card |
Standard Service Processor with embedded LOM
|
|
Remote Power/power cycle systems |
Yes |
Yes |
|
Monitor key system components (CPU, Voltages,
Chassis temperature, fans) |
Yes |
Yes |
|
Comprehensive hardware monitoring |
No |
Yes |
|
DMTF SMASH CLI command set |
Yes |
Yes |
|
Serial & Network Access |
Yes |
Yes |
|
Dedicated Management Port |
No |
Yes |
|
Serial-Over-LAN support (SOL) |
Yes |
Yes |
|
SSH support |
No |
Yes |
|
Console Redirection |
Windows, Linux & Solaris 10 with
patch 122028-02 |
Yes |
|
Comprehensive Browser interface |
No |
Yes |
|
Remote KVM |
No |
Yes |
|
Remote Media capability (DVD, CD, Floppy)
|
No |
Yes |
|
Simple GUI or CLI driven BIOS and firmware
upgrade procedure
|
No |
Yes |
|
IPMI support |
IMPI v1.5 |
IMPI v2.0 |
|
SNMP support |
No |
Yes |
Environmental
|
¡@ |
Sun Fire X2100 |
Sun Fire X2100 M2 |
Operating temperature (single, non-rack
system) |
5¢X C to 35¢X C (41¢XF to 95¢X F), 10%
to 90% relative humidity, non-condensing, 27¢X C max wet bulb
|
|
Nonoperating temperature (single, non-rack
system) |
-40 C to 65¢X C (-40¢X F to 149¢X F),
up to 93% relative humidity, non-condensing, 38¢X C max wet bulb
|
|
Altitude (operating) (single, non-rack system
|
Up to 3,000 m, maximum ambient
temperature is derated by 1¢X C per 300 m above 500 m |
|
Altitude (nonoperating) (single, non-rack
system) |
Up to 12000 m |
Power
|
¡@ |
Sun Fire X2100 |
Sun Fire X2100 M2 |
Quantity of Power Supplies |
One |
One |
|
Power Supply UL Maximum (AC input) |
5.13 Amps |
6.5 Amps |
|
Power Supply Rating (DC output) |
300 Watts |
345 Watts |
|
In Use System Power |
See the X2100 Power Calculator |
Dimensions and Weight
|
¡@ |
Sun Fire X2100 |
Sun Fire X2100 M2 |
Height |
43 mm (1.7") |
43 mm (1.7") |
|
Width |
425.5 mm (16.8") |
425.5mm (16.8") |
|
Depth |
550mm (21.7") |
633.7 mm (25") |
|
Weight (Maximum) |
13 kg (28.7 lb.) |
10.7 kg (23.45 lbs) |
Documentation
|
Product Documentation |
Latest Documents
- Where to Find Sun Fire X2100 or X2100 M2 Server
Documentation
- Sun Fire X2100 or X2100 M2 Server Product Notes
- Sun Fire X2100 or X2100 M2 Server Operating System
Installation Guide
- Embedded Lights Out Manager Adminstration Guide (X2100
M2) or Service Processor Administration Guide (X2100)
- Sun Fire X2100 or X2100 M2 Server Installation Guide
- Sun Fire X2100 or X2100 M2 Server Service Manual
- Sun Fire X2100 or X2100 M2 Server Safety and Compliance
Guide
|
Acoustic Noise Emissions
|
¡@ |
Sun Fire X2100 |
Sun Fire X2100 M2 |
Acoustic Noise Emissions |
Declared noise emissions in
accordance with ISO 9296, A-weighted, operating and idling |
|
LwAd (1B = 10dB) |
Idle, at or below 25¢X C
6.6B Max, at ambient: 7.6B |
Idle, at or below 25¢X C
6.9B Max, at ambient: 7.3B |
Regulations
|
¡@ |
Sun Fire X2100 |
Sun Fire X2100 M2 |
¡@ |
Meets or exceeds the following
requirements:
|
|
Safety |
IEC 60950, UL/CSA60950, EN60950,
CB scheme with all country differences |
|
RFI/EMI |
FCC Class A, Part 15 47 CFR,
EN55022, CISPR 22, EN300-386:v1.31, ICES-003 |
|
Immunity |
EN55024, EN300-386:v1.3.2 |
Certifications
|
¡@ |
Sun Fire X2100 |
Sun Fire X2100 M2 |
Safety |
cULus Mark, TUV GS Mark, CE Mark, CCC, GOST R,
S-Mark |
CE Mark, GOST, GS Mark, cULus Mark, CB scheme,
CCC, S Mark
|
|
EMC |
CE Mark (93/68/EEC), Emissions and Immunity
Class A Emissions Levels: FCC, VCCI, BSMI, C-Tick, MIC, CCC,
GOST |
CE Mark, Emissions and Immunity Class A
Emissions Levels: FCC, C-Tick, MIC, CCC, GOST, BSMI, ESTI, DOC,
S Mark |
|
Other |
Labeled per WEEE (Waste Electrical and
Electronic Equipment) Directive |
Labeled per WEEE (Waste Electrical and
Electronic Equipment) Directive, Reduction of Hazardous
Substances Compliant |